Verdict (computed): GO at 110 USD/MWh avoided grid tariff. Headline LCOE = 0.0910 USD/kWh (91.0 USD/MWh); NPV at 8.5% real WACC over 25 years = +3,405,624 USD; IRR = 14.20%; simple payback = 7.05 yr; discounted payback = 10.92 yr. Equipment: Jinko Solar Tiger Neo 550 Wp (JKM550N-6RL3-V) mono-PERC modules + Sungrow SG125HT string inverters on a logistics-park rooftop + canopy in sunbelt LATAM (Brazil/Chile/Mexico/Colombia). Horizon 25 yr; evidence date 2025-01-15. Limitation: this is an illustrative engineering-economic model; site-specific Solargis/PVsyst yield study, FX hedging and EPC quotes required before FID.
| Decision | Value | Basis |
|---|---|---|
| LCOE | 0.0910 USD/kWh | Computed from §3 TCO summary |
| Verdict at 110 USD/MWh tariff | GO | LCOE 91.0 < tariff 110; NPV positive 3.41M USD |
| Module class | Mono-PERC 550 Wp (Jinko JKM550N-6RL3-V) | Named OEM datasheet |
| Inverter class | Sungrow SG125HT, 125 kW string | Named OEM datasheet |
| Horizon | 25 yr | IRENA standard |
| WACC (real, after-tax) | 8.50% | TradVolt bounded default for unhedged LATAM corporate economics |
| NPV @ 8.5% | +3,405,624 USD | Computed |
| IRR | 14.20% | Computed |
| Discounted payback | 10.92 yr | Computed |
| Item | Class | Named model | OEM manual / datasheet |
|---|---|---|---|
| PV module | Mono-PERC, 550 Wp, half-cut | Jinko Solar Tiger Neo JKM550N-6RL3-V | JKM550N-6RL3-V datasheet (PDF) |
| String inverter | 125 kW, three-phase, 1500 V DC | Sungrow SG125HT | Sungrow SG125HT datasheet (PDF) |
| Mounting | Roof + canopy aluminum structure | Generic — site-specific engineering | Local building code wind/seismic report (project-specific) |
Key datasheet limits used as model assumptions: module Voc per string ≤ 1,500 V inverter max DC input (Jinko 550 Wp Voc ≈ 41.6 V, gives ~36 modules/string); inverter MPPT range per Sungrow SG125HT datasheet. String sizing and torque values must be re-verified against the OEM installation manual revision at procurement.
| Parameter | Value | Unit | Type | Source / note |
|---|---|---|---|---|
| DC capacity | 6.0 | MWp | Use-case spec | TradVolt logistics-park-solar-6mwp, r9 |
| AC capacity | 5.0847 | MW | Derived | DC/AC 1.18, per IRENA Renewable Power Generation Costs 2023 (PDF, Table 3.4) |
| Specific yield year-1 | 1,500 | kWh/kWp/yr | Use-case input | IRENA 2023 Fig. 4.9 LATAM band (1,450–1,700), central value used |
| Degradation (mono-PERC) | 0.5 | %/yr | Use-case input | NREL PV Degradation Rates — Analytical Approach (PDF, 2023 update) |
| Modules (mono-PERC 550 Wp) | 420 | USD/kWp | Use-case input | BloombergNEF Solar PV Module Prices, H2-2024 LATAM CIF series |
| String inverters | 55 | USD/kWp | Use-case input | BNEF Inverter Price Outlook 2024, string-inverter tier |
| BoS (structure, DC/AC, MV) | 260 | USD/kWp | Use-case input | IRENA 2023 Annex A1 LATAM band |
| EPC + grid | 210 | USD/kWp | Use-case input | IRENA 2023 Annex A1 LATAM band |
| Soft costs | 95 | USD/kWp | Use-case input | NREL Soft Cost Benchmark, C&I PV 2023 update (PDF) |
| Total CAPEX | 1,040 | USD/kWp | Sum | 420+55+260+210+95 |
| CAPEX total | 6,240,000 | USD | Derived | 6,000 kWp × 1,040 |
| O&M (fixed) | 13 | USD/kWp/yr | Use-case input | IRENA 2023 O&M LATAM band |
| Insurance | 0.5 | % CAPEX/yr | Use-case input | IRENA 2023 insurance band 0.4–0.7% (central) |
| Land lease | 0 | USD/yr | Use-case input | Site-owned rooftop; user to add canopy fee |
| Inverter replacement reserve | 5.5 | USD/kWp/yr | Use-case input | Industry rule-of-thumb: 25-yr string-inverter bank annualized |
| Year-15 inverter capex spike | 5 | % CAPEX | Use-case input | Bank replacement event |
| Tariff escalation | 1.5 | %/yr | Model assumption (bounded default) | LT inflation-linked LT commercial tariff trend |
| Export tariff (residual) | 0 | USD/kWh | Model assumption (bounded default) | Behind-the-meter; no export assumed |
| Residual value at year 25 | 5 | % CAPEX | Model assumption (bounded default) | End-of-life asset salvage |
| WACC (real, after-tax) | 8.5 | % | Model assumption (bounded default) | TradVolt bounded default for unhedged LATAM corporate PPA / BTM economics |
| Project life | 25 | yr | Use-case input | IRENA standard analysis horizon |
| Grid tariff offset (avoided cost, year-1) | 110 | USD/MWh | Use-case input | TradVolt LATAM weighted commercial-tariff band |
| Metric | Value |
|---|---|
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.50 % |
| Total undiscounted cost (USD) | 11,124,708.62 |
| Total discounted cost / PV of costs (USD) | 8,057,833.52 |
| Total undiscounted benefit (USD) | 29,724,970.53 |
| Total discounted benefit (USD) | 11,463,457.19 |
| NPV (USD) | 3,405,623.67 |
| IRR | 0.1420 |
| Simple payback (year) | 7.05 |
| Discounted payback (year) | 10.92 |
| LCOE (USD/kWh) | 0.0910 |
| Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
|---|---|---|---|---|---|---|
| 0 | 6,240,000.00 | 0.0000 | -6,240,000.00 | 1.00 | -6,240,000.00 | 0.0000 |
| 1 | 142,200.00 | 990,000.00 | 847,800.00 | 0.9217 | 781,382.49 | 9,000,000.00 |
| 2 | 145,044.00 | 1,004,751.00 | 859,707.00 | 0.8495 | 730,282.66 | 8,955,000.00 |
| 3 | 147,944.88 | 1,019,721.79 | 871,776.91 | 0.7829 | 682,521.20 | 8,910,225.00 |
| 4 | 150,903.78 | 1,034,915.64 | 884,011.87 | 0.7216 | 637,880.23 | 8,865,673.88 |
| 5 | 153,921.85 | 1,050,335.89 | 896,414.03 | 0.6650 | 596,156.05 | 8,821,345.51 |
| 6 | 157,000.29 | 1,065,985.89 | 908,985.60 | 0.6129 | 557,158.26 | 8,777,238.78 |
| 7 | 160,140.30 | 1,081,869.08 | 921,728.79 | 0.5649 | 520,708.88 | 8,733,352.58 |
| 8 | 163,343.10 | 1,097,988.93 | 934,645.83 | 0.5207 | 486,641.53 | 8,689,685.82 |
| 9 | 166,609.96 | 1,114,348.97 | 947,739.00 | 0.4799 | 454,800.68 | 8,646,237.39 |
| 10 | 169,942.16 | 1,130,952.77 | 961,010.60 | 0.4423 | 425,040.97 | 8,603,006.21 |
| 11 | 173,341.01 | 1,147,803.96 | 974,462.96 | 0.4076 | 397,226.50 | 8,559,991.17 |
| 12 | 176,807.83 | 1,164,906.24 | 988,098.41 | 0.3757 | 371,230.24 | 8,517,191.22 |
| 13 | 180,343.98 | 1,182,263.34 | 1,001,919.36 | 0.3463 | 346,933.45 | 8,474,605.26 |
| 14 | 183,950.86 | 1,199,879.07 | 1,015,928.21 | 0.3191 | 324,225.14 | 8,432,232.24 |
| 15 | 517,629.88 | 1,217,757.27 | 700,127.39 | 0.2941 | 205,935.39 | 8,390,071.07 |
| 16 | 191,382.48 | 1,235,901.85 | 1,044,519.37 | 0.2711 | 283,165.73 | 8,348,120.72 |
| 17 | 195,210.13 | 1,254,316.79 | 1,059,106.66 | 0.2499 | 264,627.00 | 8,306,380.12 |
| 18 | 199,114.33 | 1,273,006.11 | 1,073,891.78 | 0.2303 | 247,300.63 | 8,264,848.22 |
| 19 | 203,096.62 | 1,291,973.90 | 1,088,877.28 | 0.2122 | 231,107.43 | 8,223,523.97 |
| 20 | 207,158.55 | 1,311,224.31 | 1,104,065.76 | 0.1956 | 215,973.36 | 8,182,406.35 |
| 21 | 211,301.72 | 1,330,761.55 | 1,119,459.83 | 0.1803 | 201,829.21 | 8,141,494.32 |
| 22 | 215,527.75 | 1,350,589.90 | 1,135,062.14 | 0.1662 | 188,610.30 | 8,100,786.85 |
| 23 | 219,838.31 | 1,370,713.69 | 1,150,875.38 | 0.1531 | 176,256.17 | 8,060,282.92 |
| 24 | 224,235.08 | 1,391,137.32 | 1,166,902.25 | 0.1412 | 164,710.30 | 8,019,981.50 |
| 25 | 228,719.78 | 1,411,865.27 | 1,183,145.49 | 0.1301 | 153,919.87 | 7,979,881.59 |
The year-15 cost spike of 517,629.88 USD reflects the modeled string-inverter bank replacement event. Generation is computed as E_y = 9,000,000 × (1 − 0.005)^(y−1), with degradation per NREL PV Degradation Rates (PDF, 2023).
Each row recomputes LCOE from the formula in §5 using only the changed input.
| Scenario | CAPEX (USD/kWp) | Yield (kWh/kWp/yr) | WACC (%) | LCOE (USD/MWh) | Δ vs base |
|---|---|---|---|---|---|
| Base | 1,040 | 1,500 | 8.5 | 91.0 | — |
| Modules −10% | 998 | 1,500 | 8.5 | 85.93 | −5.07 |
| Modules +10% | 1,082 | 1,500 | 8.5 | 96.07 | +5.07 |
| Yield 1,400 (coastal/cloudier) | 1,040 | 1,400 | 8.5 | 97.51 | +6.51 |
| Yield 1,650 (high-irradiance) | 1,040 | 1,650 | 8.5 | 82.73 | −8.27 |
| WACC 6.5% | 1,040 | 1,500 | 6.5 | 80.42 | −10.58 |
| WACC 11% | 1,040 | 1,500 | 11.0 | 105.42 | +14.42 |
| Soft-cost overrun +20% | 1,059 | 1,500 | 8.5 | 92.76 | +1.76 |
| OPEX +25% | 1,040 | 1,500 | 8.5 | 95.29 | +4.29 |
| Inverter reserve doubled | 1,040 | 1,500 | 8.5 | 91.86 | +0.86 |
LCOE = 91.0 USD/MWh. Spread vs 110 USD/MWh tariff ≈ 19 USD/MWh. NPV = +3,405,624 USD; IRR 14.20%. Verdict: GO.
LCOE ≈ 82.7 USD/MWh. Spread widens to ~27 USD/MWh. Verdict: GO.
LCOE ≈ 97.5 USD/MWh. Spread shrinks to ~13 USD/MWh; inverts if WACC rises or tariffs fall. Verdict: CONDITIONAL — lock a long-term tariff floor or right-size to 4.5 MWp.
LCOE ≈ 105.4 USD/MWh. Spread compresses to ~5 USD/MWh; uneconomic at 110 USD/MWh. Verdict: NO-GO unless financed with concessional green-finance or USD-denominated PPA anchor.
LCOE ≈ 85.93 USD/MWh. Procurement-led upside. Verdict: GO.
| Item | Standard / reference | Status |
|---|---|---|
| Module cert | IEC 61215-1:2021 (IEC Webstore) / IEC 61730-1/-2 (IEC Webstore) | Pending supplier datasheet (request via RFQ) |
| Inverter cert | IEC 62109-1 (IEC Webstore) / IEC 62109-2 (IEC Webstore) | Pending supplier datasheet |
| Grid interconnection | IEEE 1547 / IEC 61727 (IEC Webstore) plus country-specific (ANEEL Brazil, CEN Chile, CRE Mexico) | Pending utility interconnection study |
| Transport (modules, sea) | UN Manual of Tests and Criteria, Part III, 38.3 (UNECE PDF) | Required for lithium-free PV modules in some sea-freight lanes (alt. UN3480/3481 not applicable) |
| Structural (rooftop) | Local building code wind/seismic load report | Pending site-specific engineering report |
| Fire / safety | NFPA 1 / local fire code | Pending AHJ review |
| Item | HS code | Description | Import duty |
|---|---|---|---|
| PV modules (mono-Si) | 8541.43 | Photovoltaic cells assembled in modules or made up into panels | PENDING — verify with EU TARIC consultation page for EU imports, or national tariff for MERCOSUR/Mexico/etc. |
| String inverters | 8504.40 | Static converters (inverters) | PENDING — verify per EU CN 2022/2554 (EUR-Lex) or national schedule |
| Mounting structure (aluminum) | 7610.90 | Aluminum structures and parts | PENDING — verify |
| Mounting structure (steel) | 7308.90 | Steel structures and parts | PENDING — verify |
| MV transformer | 8504.33 | Power transformers, ≥500 kVA | PENDING — verify |
| Cables (PV) | 8544.49 | Other electric conductors | PENDING — verify |
For US imports, also consult the USITC Harmonized Tariff Schedule pages for 8541.43 etc. For LATAM, check MERCOSUR common external tariff or national tariff schedules (e.g. ANACE in Brazil, Servicio de Impuestos Internos in Chile).
Request a sized offer with module + inverter + BoS line items for this 6 MWp logistics-park configuration:
Request RFQ — 6 MWp LATAM logistics park Browse other use-cases
| Source | URL | Used for |
|---|---|---|
| IRENA, Renewable Power Generation Costs in 2023 (PDF) | https://www.irena.org/-/media/Files/IRENA/Agency/Publication/2024/Sep/IRENA_Renewable_power_generation_costs_in_2023.pdf | DC/AC ratio, yield, BoS, EPC, O&M bands, project life horizon |
| NREL, PV Degradation Rates — Analytical Approach (PDF, 2023) | https://www.nrel.gov/docs/fy23osti/86192.pdf | Mono-PERC degradation median 0.5%/yr |
| NREL, Soft Cost Benchmark — C&I PV 2023 (PDF) | https://www.nrel.gov/docs/fy23osti/87614.pdf | Soft-cost band |
| BloombergNEF, Solar PV Module Prices (blog, cited for series) | https://about.bnef.com/blog/solar-pv-module-prices/ | LATAM CIF H2-2024 series |
| Jinko Tiger Neo JKM550N-6RL3-V datasheet (PDF) | https://www.jinkosolar.com/uploads/20231019/Tiger%20Neo%20JKM550N-6RL3-V%20IEC%20Datasheet.pdf | Mono-PERC 550 Wp module class, Voc for string sizing |
| Sungrow SG125HT datasheet (PDF) | https://en.sungrowpower.com/uploadfile/2023/03/27/SG125HT-Datasheet-EN.pdf | 125 kW string inverter class, MPPT and DC voltage limits |
| IEC 61215-1:2021 (IEC Webstore) | https://webstore.iec.ch/publication/6164 | Module design qualification |
| IEC 61730-1/-2 (IEC Webstore) | https://webstore.iec.ch/publication/6166 | Module safety |
| IEC 62109-1 (IEC Webstore) | https://webstore.iec.ch/publication/6401 | Inverter safety |
| IEC 62109-2 (IEC Webstore) | https://webstore.iec.ch/publication/6402 | Inverter safety (particular) |
| IEC 61727 (IEC Webstore) | https://webstore.iec.ch/publication/3437 | Utility-interface compliance |
| UN Manual of Tests and Criteria, Part III 38.3 (PDF) | https://www.unece.org/fileadmin/DAM/trans/danger/publi/manual/Rev5/Volume1/Part3-Chapter-1_UN_Manual_of_Tests.pdf | Transport safety reference |
| EU TARIC consultation page | https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp | HS code duty lookup (EU) |