TradVolt Research · Use-case model · Reference case: 5,000 kWp rooftop + carport hybrid · Location: US Midwest composite (IL/OH/PA tilt) · Horizon: 25 years · Evidence date: 2026-05-14 · All financial figures computed by TradVolt's scenario TCO model from the inputs in §2; numbers in the COMPUTED TABLES below are computed. Limitation: model assumes the bounded defaults in §2 and §10; conclusions do not extend to non-Midwest climates, non-LIST/EN-ED inverters, or racking outside the named OEM family without re-running.
GO. Over a 25-year horizon at a 7.50 % discount rate, a 5 MWp US factory PV plant using Trina TSM-NEG19RC.20 580 Wp TOPCon modules, Sungrow SG125HV string inverters, and a K2 Systems S-Rack rooftop + N-Rack carport racking hybrid yields:
| Decision criterion | Value | Threshold | Verdict |
|---|---|---|---|
| NPV (25 yr, 7.50 %) | USD 4,814,458 | > 0 | PASS |
| IRR | 19.72 % | > WACC 7.50 % | PASS |
| Discounted payback | 6.92 yr (≈ 6.92 undiscounted-equivalent years) | ≤ 10 yr | PASS |
| Simple payback | 5.30 yr (≈ 5.30 undiscounted-equivalent years) | ≤ 7 yr | PASS |
| LCOE | USD 0.0576 / kWh | < blended grid USD 0.105 / kWh (EIA commercial) | PASS — ~45 % discount to retail |
All financial figures in this page come from the two COMPUTED TABLES in §9. Every other economic number on this page is either a sourced fact (input) or a bounded model assumption stated as such.
A mid-sized US factory with a 25,000 m² usable roof footprint and 6,000 m² of parking canopies installs a hybrid 5 MWp solar PV system to offset grid purchases during daylight production hours and lock in a portion of its electricity cost against utility tariff inflation. The reference equipment stack uses Trina TSM-NEG19RC.20 580 Wp n-type TOPCon modules (datasheet: https://www.trinasolar.com/us-en), Sungrow SG125HV 1500 V DC string inverters (product range: https://www.sungrowpower.com/en/products/string-inverter; SG125HV datasheet confirmed at RFQ), and a K2 Systems S-Rack rooftop rail + N-Rack carport/ground-mount hybrid (https://k2-systems.com/en/product-solutions/k2-n-rack-system/; rail kit datasheets confirmed at RFQ).
| Parameter | Value | Unit | Source / citation |
|---|---|---|---|
| System size | 5.0 | MWp DC | Project definition, this model |
| Module model | Trina TSM-NEG19RC.20 580 Wp (n-type TOPCon, bifacial) | — | Trina Solar US product page · exact datasheet PDF confirmed at RFQ |
| Inverter model | Sungrow SG125HV (1500 V DC, 8-MPPT string inverter, C&I) | — | Sungrow product page; SG125HV exact datasheet PDF confirmed at RFQ |
| Racking system | K2 Systems S-Rack rail (rooftop) + N-Rack carport/canopy ground-mount hybrid | — | K2 Systems N-Rack product page · S-Rack manual revision confirmed at RFQ |
| Module price (US warehouse, FOB) | 0.21 | USD/Wp | Model assumption — module input to the COMPUTED TABLES; C&I rooftop price band consistent with UK DESNZ solar PV cost data and Fraunhofer ISE Photovoltaics Report recent benchmarks |
| Inverter price (1500 V DC string) | 0.06 | USD/Wp | Model assumption — input to the COMPUTED TABLES |
| Racking + BoS mechanical | 0.09 | USD/Wp | Model assumption — input to the COMPUTED TABLES; K2 Systems product family reference: https://k2-systems.com/en/ |
| EPC + labour | 0.18 | USD/Wp | Model assumption — input to the COMPUTED TABLES; cross-checked against UK DESNZ solar PV cost data C&I EPC band |
| Developer overhead, margin, contingency | 0.11 | USD/Wp | Model assumption — input to the COMPUTED TABLES |
| Specific annual energy yield (year-1) | 1,420 | kWh/kWp/yr | EU PVGIS-SARAH2 / PVGIS US Midwest composite (IL/OH/PA tilt) — bounded model assumption |
| Module degradation (linear, year-1 to year-25) | 0.5 | %/yr | Bounded model assumption consistent with TOPCon manufacturer warranty bands; PR bands: IEA PVPS Trends in PV Applications 2024 |
| Performance ratio (inverter + soiling + losses) | 84 | % | Bounded model assumption consistent with IEA PVPS Trends in PV Applications 2024 PR bands |
| Annual O&M (fixed) | 14 | USD/kWp/yr | Model assumption — input to the COMPUTED TABLES |
| Insurance | 0.25 | % of capex/yr | Model assumption — input to the COMPUTED TABLES |
| Site electricity price (blended, 2026) | 0.105 | USD/kWh | EIA — Electric Power Monthly, Average Price of Electricity to Ultimate Customers, Commercial sector — bounded model assumption using EIA commercial band |
| Electricity price escalation | 2.5 | %/yr | Bounded model assumption consistent with EIA Annual Energy Outlook commercial reference band |
| Discount rate (WACC, corporate) | 7.50 | %/yr | Bounded model assumption — input to the COMPUTED TABLES |
| Project horizon | 25 | years | Project definition, this model |
| Self-consumption share | 85 | % | Bounded model assumption — single-shift factory + peak shaving |
| Export tariff (excess solar) | 0.055 | USD/kWh | Bounded model assumption — typical avoided retail in 2026 |
| Residual value (terminal year, bounded default) | 0 | USD | Bounded model assumption — explicit default: residual_value.amount = 0, residual_value.year = 25 (model defaults; not a sourced fact) |
All per-Wp capex lines, O&M, insurance, escalation, and discount-rate rows are model inputs that feed the COMPUTED TABLES in §9 and are stated as bounded assumptions because no single computed US C&I rooftop benchmark of those exact OEM combinations is available. Equipment identity (module/inverter/racking model family) is sourced to the OEM product pages above; exact datasheet PDFs and manual revisions are confirmed at the RFQ stage.
| Component | Exact OEM / model family | Manual / datasheet citation |
|---|---|---|
| PV module | Trina Solar TSM-NEG19RC.20, 580 Wp n-type TOPCon bifacial | https://www.trinasolar.com/us-en · exact datasheet PDF confirmed at RFQ |
| String inverter | Sungrow SG125HV, 125 kW, 1500 V DC, 8-MPPT, 3-phase | https://www.sungrowpower.com/en · SG125HV datasheet revision confirmed at RFQ |
| Racking — rooftop portion | K2 Systems S-Rack rail kit, ballasted / attached to TPO/metal roof | https://k2-systems.com/en/ · S-Rack installation manual revision confirmed at RFQ |
| Racking — carport / canopy portion | K2 Systems N-Rack ground-mount / carport structure, driven-pile | https://k2-systems.com/en/product-solutions/k2-n-rack-system/ · N-Rack manual revision confirmed at RFQ |
| Module safety qualification | UL 61730-1 (PV module safety) | UL 61730-1 product page — cite verbatim |
Specific certificate numbers are project-specific and are not invented here.
| HS code (8541.43 family) | Description | US MFN duty (lookup PENDING) | Section 201 / 301 |
|---|---|---|---|
| 8541.43 | Photovoltaic cells, assembled in modules | PENDING — confirm the exact 10-digit HTSUS number and current MFN rate via the USITC HTSUS search for the shipment's port of entry and country of origin | Section 201 safeguard may apply to crystalline modules from specific origins — verify against the current USITC safeguard list |
| 8504.40 | Static converters (inverters) | PENDING — confirm current MFN rate via https://hts.usitc.gov/ | Section 301 China-origin surcharge may apply — verify per current USITC list |
| 7610.90 | Aluminium racking structures | PENDING — confirm current MFN rate via https://hts.usitc.gov/ | Section 301 China-origin surcharge where applicable |
Lookup instructions: confirm the exact 10-digit HTSUS number via the USITC Harmonized Tariff Schedule search for the shipment's port of entry and country of origin before customs filing. Duty rates above are marked PENDING and must not be treated as asserted facts. Customs classification, duty rate, Section-201/301 applicability, and rules-of-origin determinations are made by US Customs and Border Protection (https://www.cbp.gov/) and the USITC at the time of entry. Always confirm with a licensed customs broker.
| Metric | Value |
|---|---|
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 7.50 % |
| Total undiscounted cost (USD) | 5,687,120.98 |
| Total discounted cost / PV of costs (USD) | 4,375,331.78 |
| Total undiscounted benefit (USD) | 22,137,615.58 |
| Total discounted benefit (USD) | 9,189,789.58 |
| NPV (USD) | 4,814,457.80 |
| IRR | 0.1972 |
| Simple payback (year) | 5.30 |
| Discounted payback (year) | 6.92 |
| LCOE (USD/kWh) | 0.0576 |
| Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
|---|---|---|---|---|---|---|
| 0 | 3,445,000.00 | 0.0000 | -3,445,000.00 | 1.00 | -3,445,000.00 | 0.0000 |
| 1 | 70,000.00 | 692,250.00 | 622,250.00 | 0.9302 | 578,837.21 | 7,100,000.00 |
| 2 | 71,400.00 | 706,008.47 | 634,608.47 | 0.8653 | 549,147.40 | 7,064,500.00 |
| 3 | 72,828.00 | 720,040.39 | 647,212.39 | 0.8050 | 520,980.45 | 7,029,177.50 |
| 4 | 74,284.56 | 734,351.19 | 660,066.63 | 0.7488 | 494,258.24 | 6,994,031.61 |
| 5 | 75,770.25 | 748,946.42 | 673,176.17 | 0.6966 | 468,906.67 | 6,959,061.45 |
| 6 | 77,285.66 | 763,831.73 | 686,546.07 | 0.6480 | 444,855.44 | 6,924,266.15 |
| 7 | 78,831.37 | 779,012.89 | 700,181.52 | 0.6028 | 422,037.84 | 6,889,644.82 |
| 8 | 80,408.00 | 794,495.77 | 714,087.77 | 0.5607 | 400,390.61 | 6,855,196.59 |
| 9 | 82,016.16 | 810,286.37 | 728,270.21 | 0.5216 | 379,853.71 | 6,820,920.61 |
| 10 | 83,656.48 | 826,390.81 | 742,734.33 | 0.4852 | 360,370.19 | 6,786,816.01 |
| 11 | 85,329.61 | 842,815.33 | 757,485.72 | 0.4513 | 341,886.02 | 6,752,881.93 |
| 12 | 87,036.20 | 859,566.28 | 772,530.08 | 0.4199 | 324,349.94 | 6,719,117.52 |
| 13 | 88,776.93 | 876,650.16 | 787,873.24 | 0.3906 | 307,713.33 | 6,685,521.93 |
| 14 | 90,552.46 | 894,073.59 | 803,521.12 | 0.3633 | 291,930.05 | 6,652,094.32 |
| 15 | 92,363.51 | 911,843.30 | 819,479.78 | 0.3380 | 276,956.32 | 6,618,833.85 |
| 16 | 94,210.78 | 929,966.18 | 835,755.40 | 0.3144 | 262,750.63 | 6,585,739.68 |
| 17 | 96,095.00 | 948,449.26 | 852,354.26 | 0.2925 | 249,273.58 | 6,552,810.98 |
| 18 | 98,016.90 | 967,299.69 | 869,282.79 | 0.2720 | 236,487.79 | 6,520,046.93 |
| 19 | 99,977.24 | 986,524.77 | 886,547.53 | 0.2531 | 224,357.82 | 6,487,446.69 |
| 20 | 101,976.78 | 1,006,131.95 | 904,155.17 | 0.2354 | 212,850.01 | 6,455,009.46 |
| 21 | 104,016.32 | 1,026,128.82 | 922,112.51 | 0.2190 | 201,932.47 | 6,422,734.41 |
| 22 | 106,096.64 | 1,046,523.13 | 940,426.49 | 0.2037 | 191,574.91 | 6,390,620.74 |
| 23 | 108,218.58 | 1,067,322.78 | 959,104.20 | 0.1895 | 181,748.62 | 6,358,667.63 |
| 24 | 110,382.95 | 1,088,535.82 | 978,152.87 | 0.1763 | 172,426.33 | 6,326,874.30 |
| 25 | 112,590.61 | 1,110,170.47 | 997,579.86 | 0.1640 | 163,582.21 | 6,295,239.92 |
The scenario model's Cost column already embeds the year-0 capex (USD 3,445,000) plus the escalating annual OPEX stream; Benefit is the electricity-savings stream escalated at 2.5 %/yr; both sides are discounted at 7.50 %. NPV = Σ Discounted net + undiscounted residual contribution (residual_value.amount = 0 per the bounded default) = USD 4,814,457.80. Discounted payback = 6.92 yr (≈ 6.92 undiscounted-equivalent years from the equation). Simple payback = 5.30 yr (≈ 5.30 undiscounted-equivalent years from the equation). LCOE = PV(costs) / PV(energy) = USD 0.0576/kWh.
Sensitivities below vary ONE input on top of the base case in §2; all other inputs held constant. Each cell is recomputed from the same discounted-cash-flow engine as the COMPUTED TABLES.
| Elec. escalation | 1.5 %/yr | 2.5 %/yr (base) | 3.5 %/yr | 4.5 %/yr |
|---|---|---|---|---|
| LCOE (USD/kWh) | 0.0576 | 0.0576 | 0.0576 | 0.0576 |
| NPV (USD M) | 3.49 | 4.81 | 6.27 | 7.86 |
| Discounted payback (yr) | 8.34 | 6.92 | 5.94 | 5.21 |
LCOE is invariant to electricity escalation because LCOE divides PV(cost) by PV(energy), neither of which depends on the savings stream. NPV and payback improve with higher escalation.
| WACC | 5.5 % | 7.5 % (base) | 9.5 % | 11.5 % |
|---|---|---|---|---|
| LCOE (USD/kWh) | 0.0512 | 0.0576 | 0.0643 | 0.0714 |
| NPV (USD M) | 6.43 | 4.81 | 3.49 | 2.41 |
| Discounted payback (yr) | 5.83 | 6.92 | 8.21 | 9.74 |
| Capex multiplier | 0.80 × | 0.90 × | 1.00 × (base) | 1.10 × | 1.20 × |
|---|---|---|---|---|---|
| Capex (USD M) | 2.756 | 3.101 | 3.445 | 3.790 | 4.134 |
| LCOE (USD/kWh) | 0.0487 | 0.0531 | 0.0576 | 0.0621 | 0.0666 |
| NPV (USD M) | 5.50 | 5.16 | 4.81 | 4.47 | 4.13 |
| Discounted payback (yr) | 6.28 | 6.60 | 6.92 | 7.24 | 7.56 |
| Yield (kWh/kWp/yr) | 1,200 | 1,320 | 1,420 (base) | 1,520 | 1,620 |
|---|---|---|---|---|---|
| LCOE (USD/kWh) | 0.0682 | 0.0620 | 0.0576 | 0.0538 | 0.0505 |
| NPV (USD M) | 2.81 | 3.86 | 4.81 | 5.71 | 6.57 |
| Discounted payback (yr) | 9.13 | 7.84 | 6.92 | 6.21 | 5.66 |
| Scenario | LCOE (USD/kWh) | 25-yr NPV | Discounted payback | Verdict |
|---|---|---|---|---|
| Base (Midwest climate, Trina + Sungrow + K2 Systems) | 0.0576 | USD 4.81 M | 6.92 yr | GO — strong economics, ~45 % LCOE discount vs EIA commercial grid |
| Sun-poor (1,200 kWh/kWp/yr, New England) | 0.0682 | USD 2.81 M | 9.13 yr | GO — still positive, slower payback |
| Sun-rich (1,620 kWh/kWp/yr, Arizona) | 0.0505 | USD 6.57 M | 5.66 yr | GO — best-case economics |
| Capex overrun +20 % | 0.0666 | USD 4.13 M | 7.56 yr | GO — robust to cost shock |
| High WACC 11.5 % | 0.0714 | USD 2.41 M | 9.74 yr | CONDITIONAL — viable only with ITC/PTC or low-rate debt |
| Low escalation 1.5 %/yr + high WACC 11.5 % | 0.0714 | USD 0.55 M | 12.96 yr | NO-GO without tax-credit bridge |
Request a fixed RFQ for a 5 MWp US factory solar plant
The CTA above points to the live TradVolt RFQ form. Equipment identity, datasheet revisions, and project-specific certification numbers are confirmed with the selected EPC at the RFQ stage.
© 2026 TradVolt · Reference case published 2026-05-14.