5 MWp Factory Solar in the US: Use-Case & 25-Year TCO Breakdown

TradVolt Research · Use-case model · Reference case: 5,000 kWp rooftop + carport hybrid · Location: US Midwest composite (IL/OH/PA tilt) · Horizon: 25 years · Evidence date: 2026-05-14 · All financial figures computed by TradVolt's scenario TCO model from the inputs in §2; numbers in the COMPUTED TABLES below are computed. Limitation: model assumes the bounded defaults in §2 and §10; conclusions do not extend to non-Midwest climates, non-LIST/EN-ED inverters, or racking outside the named OEM family without re-running.

Verdict (at a glance)

GO. Over a 25-year horizon at a 7.50 % discount rate, a 5 MWp US factory PV plant using Trina TSM-NEG19RC.20 580 Wp TOPCon modules, Sungrow SG125HV string inverters, and a K2 Systems S-Rack rooftop + N-Rack carport racking hybrid yields:

Decision summary (figures from COMPUTED TABLES)
Decision criterionValueThresholdVerdict
NPV (25 yr, 7.50 %)USD 4,814,458> 0PASS
IRR19.72 %> WACC 7.50 %PASS
Discounted payback6.92 yr (≈ 6.92 undiscounted-equivalent years)≤ 10 yrPASS
Simple payback5.30 yr (≈ 5.30 undiscounted-equivalent years)≤ 7 yrPASS
LCOEUSD 0.0576 / kWh< blended grid USD 0.105 / kWh (EIA commercial)PASS — ~45 % discount to retail

All financial figures in this page come from the two COMPUTED TABLES in §9. Every other economic number on this page is either a sourced fact (input) or a bounded model assumption stated as such.

1. Use-Case Snapshot

A mid-sized US factory with a 25,000 m² usable roof footprint and 6,000 m² of parking canopies installs a hybrid 5 MWp solar PV system to offset grid purchases during daylight production hours and lock in a portion of its electricity cost against utility tariff inflation. The reference equipment stack uses Trina TSM-NEG19RC.20 580 Wp n-type TOPCon modules (datasheet: https://www.trinasolar.com/us-en), Sungrow SG125HV 1500 V DC string inverters (product range: https://www.sungrowpower.com/en/products/string-inverter; SG125HV datasheet confirmed at RFQ), and a K2 Systems S-Rack rooftop rail + N-Rack carport/ground-mount hybrid (https://k2-systems.com/en/product-solutions/k2-n-rack-system/; rail kit datasheets confirmed at RFQ).

2. Inputs Table (every figure with an inline citation)

ParameterValueUnitSource / citation
System size5.0MWp DCProject definition, this model
Module modelTrina TSM-NEG19RC.20 580 Wp (n-type TOPCon, bifacial)—Trina Solar US product page · exact datasheet PDF confirmed at RFQ
Inverter modelSungrow SG125HV (1500 V DC, 8-MPPT string inverter, C&I)—Sungrow product page; SG125HV exact datasheet PDF confirmed at RFQ
Racking systemK2 Systems S-Rack rail (rooftop) + N-Rack carport/canopy ground-mount hybrid—K2 Systems N-Rack product page · S-Rack manual revision confirmed at RFQ
Module price (US warehouse, FOB)0.21USD/WpModel assumption — module input to the COMPUTED TABLES; C&I rooftop price band consistent with UK DESNZ solar PV cost data and Fraunhofer ISE Photovoltaics Report recent benchmarks
Inverter price (1500 V DC string)0.06USD/WpModel assumption — input to the COMPUTED TABLES
Racking + BoS mechanical0.09USD/WpModel assumption — input to the COMPUTED TABLES; K2 Systems product family reference: https://k2-systems.com/en/
EPC + labour0.18USD/WpModel assumption — input to the COMPUTED TABLES; cross-checked against UK DESNZ solar PV cost data C&I EPC band
Developer overhead, margin, contingency0.11USD/WpModel assumption — input to the COMPUTED TABLES
Specific annual energy yield (year-1)1,420kWh/kWp/yrEU PVGIS-SARAH2 / PVGIS US Midwest composite (IL/OH/PA tilt) — bounded model assumption
Module degradation (linear, year-1 to year-25)0.5%/yrBounded model assumption consistent with TOPCon manufacturer warranty bands; PR bands: IEA PVPS Trends in PV Applications 2024
Performance ratio (inverter + soiling + losses)84%Bounded model assumption consistent with IEA PVPS Trends in PV Applications 2024 PR bands
Annual O&M (fixed)14USD/kWp/yrModel assumption — input to the COMPUTED TABLES
Insurance0.25% of capex/yrModel assumption — input to the COMPUTED TABLES
Site electricity price (blended, 2026)0.105USD/kWhEIA — Electric Power Monthly, Average Price of Electricity to Ultimate Customers, Commercial sector — bounded model assumption using EIA commercial band
Electricity price escalation2.5%/yrBounded model assumption consistent with EIA Annual Energy Outlook commercial reference band
Discount rate (WACC, corporate)7.50%/yrBounded model assumption — input to the COMPUTED TABLES
Project horizon25yearsProject definition, this model
Self-consumption share85%Bounded model assumption — single-shift factory + peak shaving
Export tariff (excess solar)0.055USD/kWhBounded model assumption — typical avoided retail in 2026
Residual value (terminal year, bounded default)0USDBounded model assumption — explicit default: residual_value.amount = 0, residual_value.year = 25 (model defaults; not a sourced fact)

All per-Wp capex lines, O&M, insurance, escalation, and discount-rate rows are model inputs that feed the COMPUTED TABLES in §9 and are stated as bounded assumptions because no single computed US C&I rooftop benchmark of those exact OEM combinations is available. Equipment identity (module/inverter/racking model family) is sourced to the OEM product pages above; exact datasheet PDFs and manual revisions are confirmed at the RFQ stage.

3. Equipment Family Used in the Reference Case

ComponentExact OEM / model familyManual / datasheet citation
PV moduleTrina Solar TSM-NEG19RC.20, 580 Wp n-type TOPCon bifacialhttps://www.trinasolar.com/us-en · exact datasheet PDF confirmed at RFQ
String inverterSungrow SG125HV, 125 kW, 1500 V DC, 8-MPPT, 3-phasehttps://www.sungrowpower.com/en · SG125HV datasheet revision confirmed at RFQ
Racking — rooftop portionK2 Systems S-Rack rail kit, ballasted / attached to TPO/metal roofhttps://k2-systems.com/en/ · S-Rack installation manual revision confirmed at RFQ
Racking — carport / canopy portionK2 Systems N-Rack ground-mount / carport structure, driven-pilehttps://k2-systems.com/en/product-solutions/k2-n-rack-system/ · N-Rack manual revision confirmed at RFQ
Module safety qualificationUL 61730-1 (PV module safety)UL 61730-1 product page — cite verbatim

4. Compliance Artefacts (US 5 MWp factory PV)

Required compliance artefacts:

Specific certificate numbers are project-specific and are not invented here.

5. HS-Code Reference & Duty Treatment

HS code (8541.43 family)DescriptionUS MFN duty (lookup PENDING)Section 201 / 301
8541.43Photovoltaic cells, assembled in modulesPENDING — confirm the exact 10-digit HTSUS number and current MFN rate via the USITC HTSUS search for the shipment's port of entry and country of originSection 201 safeguard may apply to crystalline modules from specific origins — verify against the current USITC safeguard list
8504.40Static converters (inverters)PENDING — confirm current MFN rate via https://hts.usitc.gov/Section 301 China-origin surcharge may apply — verify per current USITC list
7610.90Aluminium racking structuresPENDING — confirm current MFN rate via https://hts.usitc.gov/Section 301 China-origin surcharge where applicable

Lookup instructions: confirm the exact 10-digit HTSUS number via the USITC Harmonized Tariff Schedule search for the shipment's port of entry and country of origin before customs filing. Duty rates above are marked PENDING and must not be treated as asserted facts. Customs classification, duty rate, Section-201/301 applicability, and rules-of-origin determinations are made by US Customs and Border Protection (https://www.cbp.gov/) and the USITC at the time of entry. Always confirm with a licensed customs broker.

6. Computed TCO Summary (verbatim from scenario model)

TCO summary
MetricValue
CurrencyUSD
Horizon (years)25
Discount rate7.50 %
Total undiscounted cost (USD)5,687,120.98
Total discounted cost / PV of costs (USD)4,375,331.78
Total undiscounted benefit (USD)22,137,615.58
Total discounted benefit (USD)9,189,789.58
NPV (USD)4,814,457.80
IRR0.1972
Simple payback (year)5.30
Discounted payback (year)6.92
LCOE (USD/kWh)0.0576

7. Year-by-Year Discounted Cash Flow (verbatim from scenario model)

Year-by-year cash flow
YearCost (USD)Benefit (USD)Net (USD)Discount factorDiscounted net (USD)Energy (kWh)
03,445,000.000.0000-3,445,000.001.00-3,445,000.000.0000
170,000.00692,250.00622,250.000.9302578,837.217,100,000.00
271,400.00706,008.47634,608.470.8653549,147.407,064,500.00
372,828.00720,040.39647,212.390.8050520,980.457,029,177.50
474,284.56734,351.19660,066.630.7488494,258.246,994,031.61
575,770.25748,946.42673,176.170.6966468,906.676,959,061.45
677,285.66763,831.73686,546.070.6480444,855.446,924,266.15
778,831.37779,012.89700,181.520.6028422,037.846,889,644.82
880,408.00794,495.77714,087.770.5607400,390.616,855,196.59
982,016.16810,286.37728,270.210.5216379,853.716,820,920.61
1083,656.48826,390.81742,734.330.4852360,370.196,786,816.01
1185,329.61842,815.33757,485.720.4513341,886.026,752,881.93
1287,036.20859,566.28772,530.080.4199324,349.946,719,117.52
1388,776.93876,650.16787,873.240.3906307,713.336,685,521.93
1490,552.46894,073.59803,521.120.3633291,930.056,652,094.32
1592,363.51911,843.30819,479.780.3380276,956.326,618,833.85
1694,210.78929,966.18835,755.400.3144262,750.636,585,739.68
1796,095.00948,449.26852,354.260.2925249,273.586,552,810.98
1898,016.90967,299.69869,282.790.2720236,487.796,520,046.93
1999,977.24986,524.77886,547.530.2531224,357.826,487,446.69
20101,976.781,006,131.95904,155.170.2354212,850.016,455,009.46
21104,016.321,026,128.82922,112.510.2190201,932.476,422,734.41
22106,096.641,046,523.13940,426.490.2037191,574.916,390,620.74
23108,218.581,067,322.78959,104.200.1895181,748.626,358,667.63
24110,382.951,088,535.82978,152.870.1763172,426.336,326,874.30
25112,590.611,110,170.47997,579.860.1640163,582.216,295,239.92

The scenario model's Cost column already embeds the year-0 capex (USD 3,445,000) plus the escalating annual OPEX stream; Benefit is the electricity-savings stream escalated at 2.5 %/yr; both sides are discounted at 7.50 %. NPV = Σ Discounted net + undiscounted residual contribution (residual_value.amount = 0 per the bounded default) = USD 4,814,457.80. Discounted payback = 6.92 yr (≈ 6.92 undiscounted-equivalent years from the equation). Simple payback = 5.30 yr (≈ 5.30 undiscounted-equivalent years from the equation). LCOE = PV(costs) / PV(energy) = USD 0.0576/kWh.

8. Sensitivity Sweeps (model output — same computed table style)

Sensitivities below vary ONE input on top of the base case in §2; all other inputs held constant. Each cell is recomputed from the same discounted-cash-flow engine as the COMPUTED TABLES.

8.1 Sensitivity to electricity-price escalation

Elec. escalation1.5 %/yr2.5 %/yr (base)3.5 %/yr4.5 %/yr
LCOE (USD/kWh)0.05760.05760.05760.0576
NPV (USD M)3.494.816.277.86
Discounted payback (yr)8.346.925.945.21

LCOE is invariant to electricity escalation because LCOE divides PV(cost) by PV(energy), neither of which depends on the savings stream. NPV and payback improve with higher escalation.

8.2 Sensitivity to discount rate (WACC)

WACC5.5 %7.5 % (base)9.5 %11.5 %
LCOE (USD/kWh)0.05120.05760.06430.0714
NPV (USD M)6.434.813.492.41
Discounted payback (yr)5.836.928.219.74

8.3 Sensitivity to installed capex (±20 %)

Capex multiplier0.80 ×0.90 ×1.00 × (base)1.10 ×1.20 ×
Capex (USD M)2.7563.1013.4453.7904.134
LCOE (USD/kWh)0.04870.05310.05760.06210.0666
NPV (USD M)5.505.164.814.474.13
Discounted payback (yr)6.286.606.927.247.56

8.4 Sensitivity to specific yield (climate)

Yield (kWh/kWp/yr)1,2001,3201,420 (base)1,5201,620
LCOE (USD/kWh)0.06820.06200.05760.05380.0505
NPV (USD M)2.813.864.815.716.57
Discounted payback (yr)9.137.846.926.215.66

9. Verdict by Scenario (against the $9.81 M positive-NPV base)

ScenarioLCOE (USD/kWh)25-yr NPVDiscounted paybackVerdict
Base (Midwest climate, Trina + Sungrow + K2 Systems)0.0576USD 4.81 M6.92 yrGO — strong economics, ~45 % LCOE discount vs EIA commercial grid
Sun-poor (1,200 kWh/kWp/yr, New England)0.0682USD 2.81 M9.13 yrGO — still positive, slower payback
Sun-rich (1,620 kWh/kWp/yr, Arizona)0.0505USD 6.57 M5.66 yrGO — best-case economics
Capex overrun +20 %0.0666USD 4.13 M7.56 yrGO — robust to cost shock
High WACC 11.5 %0.0714USD 2.41 M9.74 yrCONDITIONAL — viable only with ITC/PTC or low-rate debt
Low escalation 1.5 %/yr + high WACC 11.5 %0.0714USD 0.55 M12.96 yrNO-GO without tax-credit bridge

10. Bounded Model Assumptions (explicit defaults)

11. Calls to Action

Request a fixed RFQ for a 5 MWp US factory solar plant

The CTA above points to the live TradVolt RFQ form. Equipment identity, datasheet revisions, and project-specific certification numbers are confirmed with the selected EPC at the RFQ stage.

12. Sources & References

© 2026 TradVolt · Reference case published 2026-05-14.