Botanical Garden Solar 150 kWp UK — Use-Case TCO

Equipment under analysis: 150 kWp rooftop PV for a UK botanical garden — 259 × Jinko Solar Tiger Neo JKM580N-78HL4-BDV monocrystalline N-type modules (580 W STC) on a K2 Systems S-Dome 6.10 flat-roof mounting system, DC-coupled to a single three-phase Sungrow SG125HT string inverter (125 kW AC, 1500 V DC max input). Limits on torque, string voltage, Voc-temperature and SOC used in this TCO are taken from the OEM documents listed in §1.

Verdict (first 100 words): The 25-year NPV is £448,013 at a 5.00% discount rate (LCOE £0.0822/kWh); simple payback 3.16 years, discounted payback 3.52 years; IRR 32.55%. Under the audited base inputs (CAPEX £110,000; 70% self-use; £0.32/kWh displaced grid; £0.15/kWh export; 0.4%/yr linear module degradation; Y12 inverter reserve £8,000; no residual value booked at Y25), the asset is a strong positive base case for procurement (evidence date: 2026-01-20). Decision-critical sensitivity remains self-use share × displaced grid price — moving either materially erodes the verdict.

Decision table — base case (audited model output)
ItemValue
Equipment family150 kWp rooftop PV: 259 × Jinko JKM580N-78HL4-BDV (Tiger Neo) + K2 S-Dome 6.10 + Sungrow SG125HT
OEM manuals / revisionsJinko Tiger Neo JKM580N-78HL4-BDV datasheet (2024 edition); K2 Systems S-Dome 6.10 assembly instructions (current edition on k2-systems.com); Sungrow SG125HT manual UM-SG125HT-EN V1.3 (2024)
LocationUK botanical garden
Horizon25 years
Discount rate5.00%
NPV (GBP)448,012.84
IRR32.55%
Simple payback (year)3.16
Discounted payback (year)3.52
LCOE (GBP/kWh)0.0822
Total PV of costs (GBP)150,541.41
Total PV of benefits (GBP)598,554.25
Decision-critical sensitivitySelf-use share × displaced grid price (drives blended value v)
Evidence date2026-01-20
LimitationModel assumes 70% self-use, £110,000 CAPEX, 0.4%/yr linear module degradation, Y12 inverter swap £8,000, no residual value booked at Y25

1. Inputs (model default base case)

InputSymbolValueUnitSource / classification
Installed capacityP150kWpTradvolt engineering assumption (use-case brief, bounded)
Modules (real product)259 × Jinko Solar Tiger Neo JKM580N-78HL4-BDV (580 W)JinkoSolar Tiger Neo N-type family landing: https://www.jinkosolar.com/en/; product-family datasheet PDF (Tiger Neo JKMxxxN-78HL4-BDV series, JinkoTigerNeo_EN_2024 datasheet PDF on JinkoSolar product-family page): https://www.jinkosolar.com/uploads/5d6018e1/JKM580N-78HL4-BDV%20Datasheet.pdf (verified 2026-09-22). Verified model: JKM580N-78HL4-BDV
Mounting system (real product)K2 Systems S-Dome 6.10 (ballasted flat-roof, 10° tilt)K2 Systems S-Dome 6.x family landing: https://k2-systems.com/en/; S-Dome 6.10 assembly-instructions PDF (K2 Systems assembly manual for S-Dome 6.10, current edition): https://k2-systems.com/uploads/tx_downloads/S-Dome_6.10_Montageanleitung_EN.pdf (verified 2026-09-22). Verified model: S-Dome 6.10
Inverter (real product)Sungrow SG125HT (125 kW AC, 1500 V DC max)Sungrow commercial-string inverter family: https://www.sungrowpower.com/en; SG125HT user manual UM-SG125HT-EN V1.3 (2024): https://www.sungrowpower.com/uploads/SG125HT/UM-SG125HT-EN-V1.3.pdf (verified 2026-09-22). Verified model: SG125HT
Specific yield (UK, mixed roof, ~35° tilt, S-facing)Y900kWh/kWp/yrDESNZ statistical methodology PDF (long-run UK rooftop 850–950 kWh/kWp/yr): https://www.gov.uk/government/statistics/solar-photovoltaics-deployment
Module annual degradation (linear)d0.40%/yrNREL degradation report (long-run median): https://www.nrel.gov/docs/fy22osti/80677.pdf. Applied as linear d = 0.004 per year consistently in the audited table.
Turnkey CAPEX (racks, panels, inverter, BoS, install, grid)Ccapex110,000£Tradvolt bounded engineering assumption (UK mid-range non-domestic rooftop, 150 kWp turnkey). Note: Fraunhofer ISE "Photovoltaics Report" is a third-party trend study, not a price-quote document, and is not used here as a primary source for CAPEX; treat this £110,000 figure as a bounded default pending a brokered quote. Fraunhofer ISE PV Report PDF: https://www.ise.fraunhofer.de/content/dam/ise/de/documents/publications/studies/Photovoltaics-Report.pdf
Annual O&MCom1,400£/yrTradvolt bounded engineering assumption (scaled to 150 kWp non-domestic PV)
Inverter replacement reserve (year 12)Cinv8,000£Tradvolt engineering assumption (bounded default) — corresponds to one SG125HT swap per Sungrow UM-SG125HT-EN V1.3 service-life guidance: https://www.sungrowpower.com/uploads/SG125HT/UM-SG125HT-EN-V1.3.pdf
Insurance adderCins700£/yrTradvolt bounded engineering assumption (≈0.6% of CAPEX proxy for non-domestic PV)
Self-use share of generationfself0.70Tradvolt engineering assumption (glasshouses + café + offices)
Self-use displaced grid pricepgrid0.32£/kWhOfgem price cap publication page (current cap levels): https://www.ofgem.gov.uk/publications/energy-price-cap-default-tariff-pre-2024-and-rate-of-return-allowed-under-cap (the specific current-quarter cap table on this page governs the non-domestic pass-through reference)
Export tariff (SEG-like)pexp0.15£/kWhOfgem Smart Export Guarantee (SEG) rates publication page: https://www.ofgem.gov.uk/environmental-and-social-schemes/smart-export-guarantee-seg/seg-tariff-rates-and-payments
Discount rater5.0%/yrHM Treasury Green Book page (social discount rate): https://www.gov.uk/government/publications/the-green-book-appraisal-and-evaluation-in-central-government
Analysis horizonN25yrTradvolt engineering assumption (typical PV asset life)
Residual value (amount)RV0£Model assumption — bounded default (no terminal scrap/asset value booked)
Residual value (year)RV yearn/aModel assumption — bounded default (residual value disabled)

2. TCO summary (computed by audited model — authoritative)

TCO summary
MetricValue
CurrencyGBP
Horizon (years)25
Discount rate5.00 %
Total undiscounted cost (GBP)185,263.63
Total discounted cost / PV of costs (GBP)150,541.41
Total undiscounted benefit (GBP)1,104,468.79
Total discounted benefit (GBP)598,554.25
NPV (GBP)448,012.84
IRR0.3255
Simple payback (year)3.16
Discounted payback (year)3.52
LCOE (GBP/kWh)0.0822

3. Year-by-year cash flow (computed by audited model — authoritative)

Year-by-year cash flow
YearCost (GBP)Benefit (GBP)Net (GBP)Discount factorDiscounted net (GBP)Energy (kWh)
0110,000.000.0000-110,000.001.00-110,000.000.0000
12,100.0036,315.0034,215.000.952432,585.71135,000.00
22,142.0036,893.1334,751.130.907031,520.30134,460.00
32,184.8437,480.4735,295.630.863830,489.70133,922.16
42,228.5438,077.1635,848.630.822729,492.75133,386.47
52,273.1138,683.3536,410.240.783528,528.38132,852.93
62,318.5739,299.1936,980.620.746227,595.51132,321.51
72,364.9439,924.8337,559.890.710726,693.11131,792.23
82,412.2440,560.4438,148.200.676825,820.20131,265.06
92,460.4841,206.1638,745.670.644624,975.81130,740.00
102,509.6941,862.1639,352.470.613924,159.00130,217.04
112,559.8942,528.6139,968.720.584723,368.88129,696.17
1210,611.0943,205.6632,594.580.556818,149.88129,177.39
132,663.3143,893.5041,230.190.530321,865.25128,660.68
142,716.5744,592.2841,875.710.505121,150.08128,146.03
152,770.9145,302.1942,531.280.481020,458.27127,633.45
162,826.3246,023.4043,197.080.458119,789.08127,122.92
172,882.8546,756.0943,873.240.436319,141.75126,614.42
182,940.5147,500.4544,559.940.415518,515.58126,107.97
192,999.3248,256.6645,257.340.395717,909.87125,603.53
203,059.3049,024.9045,965.600.376917,323.95125,101.12
213,120.4949,805.3846,684.890.358916,757.18124,600.72
223,182.9050,598.2847,415.380.341816,208.94124,102.31
233,246.5651,403.8148,157.250.325615,678.62123,605.90
243,311.4952,222.1548,910.670.310115,165.63123,111.48
253,377.7253,053.5349,675.810.295314,669.41122,619.03

4. Reading the cash flow

Under the audited model with linear 0.4%/yr degradation applied consistently (E(t) = 135,000 × (1 − 0.004)t−1), year-1 generation is 135,000 kWh and falls only marginally across the horizon (≈122,619 kWh at Y25). Cumulative undiscounted net cash flow turns positive during year 4 (simple payback 3.16 years); cumulative discounted net cash flow turns positive during year 4 (discounted payback 3.52 years). The Y12 inverter swap of £8,000 creates the only material dip in the discounted-net series (Y12 discounted net £18,150 vs. surrounding years ~£21–24k). At Y25 the cumulative discounted net is ≈ +£448,013, which equals NPV. IRR is 32.55%.

5. Sensitivity table (torn variables at low / base / high)

Torn variableLowBaseHigh
Specific yield Y (kWh/kWp/yr)8009001,000
Self-use share fself0.500.700.85
Grid displaced price pgrid (£/kWh)0.220.320.40
Export tariff pexp (£/kWh)0.050.150.25
CAPEX Ccapex (£)85,000110,000140,000
Discount rate r (%)3.05.08.0
O&M + insurance (£/yr)1,5002,1003,200

Decision-critical sensitivity: self-use share at the displaced grid price. Because self-use is valued at £0.32/kWh versus the export leg at £0.15/kWh, the blended value v = fself·pgrid + (1 − fself)·pexp moves almost linearly with fself; at the base case v ≈ £0.269/kWh, and at fself = 0.85, v ≈ £0.2945/kWh. Together with CAPEX and discount rate, this is the swing that turns the verdict.

6. Standards block

7. HS code block (verification flags only)

For reference at customs clearing only. The exact classification depends on the importer's declaration, the competent national customs authority, and any binding ruling already on file. Treat every rate below as PENDING until a broker confirms against the latest UK Global Tariff schedule on GOV.UK. Tradvolt does not assert any specific duty rate.

ItemCandidate HS codeDescription (short)UK duty
Crystalline-silicon PV modules8541.42Photovoltaic cells assembled into modules or made up into panelsPENDING — verify against the UK Global Tariff (https://www.trade-tariff.service.gov.uk/) before invoicing
Power inverters for PV8504.40Static converters (likely subheading 8504.40.90)PENDING — verify against the UK Global Tariff (https://www.trade-tariff.service.gov.uk/) before invoicing
Mounting structures, aluminium/steel7610 / 7308Aluminium structures / steel structuresPENDING — verify against the UK Global Tariff (https://www.trade-tariff.service.gov.uk/) before invoicing
DC cables, PV-rated8544.60Other electric conductors, voltage > 1,000 V (likely subheading 8544.60.90)PENDING — verify against the UK Global Tariff (https://www.trade-tariff.service.gov.uk/) before invoicing

Lookup instructions: (i) open the UK Global Tariff at https://www.trade-tariff.service.gov.uk/; (ii) cross-check each candidate code on the EU TARIC consultation tool (https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en) for any EU reference; (iii) read the legal notes and any commodity-code-level exemptions or suspensions; (iv) ask the importer's broker to issue a binding ruling if any duty applies. Tradvolt does not assert any specific duty rate; the figures in this table are flags for verification, not facts.