Home › Processes & SOPs › Battery Pack Hipot (Dielectric) Test SOP
Verdict (this SOP, run as written): PASS-disposition rule. A unit PASSES if (a) leakage current during the 60 s dwell at 2 120 V AC remains ≤ 10 mA (CATL LFP-280Ah Service Manual Rev. 1.4 §5.1), AND (b) the lot passes ISO 2859-1:1999 Normal-inspection Level II sampling at AQL 1.0 (major) / 2.5 (minor). Default sampling outcome for the reference 50-pack lot (Level II, AQL 1.0) = Ac=1, Re=2; sample size n=8. Equipment: EVSE-integrated LFP battery pack. Location: CN hub → PK field site. Horizon: 2026 CN→PK service window. Evidence date: 2026-09-21. Limitation: parametric values below are indicative; final values come from the OEM service manual for the specific pack model in scope (see §2).
| Item | Value |
|---|---|
| Disposition rule | PASS / FAIL (per §4 thresholds) |
| Sample size (Level II, lot 26–50) | n = 8 |
| Accept number (AQL 1.0 major) | Ac = 1 |
| Reject number (AQL 1.0 major) | Re = 2 |
| Dwell / voltage / trip | 60 s / 2 120 V AC / 10 mA |
| Corridor lead-time (multimodal CN→PK) | 7–14 days indicative |
| HS code (proposed) | 8507.60 — PENDING lookup |
Request Quote — replies in 48h Download Checklist (PDF, via RFQ form)
Applies to EVSE battery packs that arrive at a TradVolt service node (CN hub → PK field site) with symptoms including insulation breakdown, moisture ingress, or post-impact diagnostics. Excludes AC EVSE controller boards and DC fast-charger power modules, which follow separate dielectric SOPs tied to the EVSE OEM service manual. The reference equipment family in scope is the CATL LFP BatteryPack (LFP-280Ah); numeric test limits in this SOP are taken from the CATL LFP-280Ah Service Manual Rev. 1.4 (2025-08-12).
| Step # | Action | Owner | Input doc | Output doc | Done-when |
|---|---|---|---|---|---|
| 1 | Receive work order, equipment manifest, and incoming inspection record; reconcile serial numbers. | Service Coordinator (CN hub) | WO-XXXX.pdf, INCOMING-CHECK.xlsx |
WO-ACK.pdf |
Manifest lines match WO line items; discrepancies logged. |
| 2 | Verify PPE (dielectric gloves, face shield, insulated mat), tools, and tester calibration validity. | Test Technician | PPE-CHECKLIST.pdf, CAL-CERT-HIPOT-XXX.pdf |
PRE-TEST-READY.pdf |
Calibration date within validity period; PPE items signed off. |
| 3 | Apply LOTO per CATL LFP-280Ah Service Manual Rev. 1.4 §3.2; verify zero energy with a calibrated multimeter. | Test Technician | OEM-LOTO-SEQUENCE.pdf |
LOTO-TAG.png |
Multimeter reads 0 V DC on pack HV terminals; tag affixed. |
| 4 | Configure tester: 2 120 V AC, 10 s ramp, 60 s dwell, 10 mA trip — per CATL LFP-280Ah Service Manual Rev. 1.4 §5.1. | Test Technician | OEM-DATASHEET-PACK.pdf |
TESTER-PROFILE.dat |
Set values recorded on the test record and counter-signed by QA. |
| 5 | Connect HV lead to the live conductor bundle and return lead to the chassis ground reference. | Test Technician | LEAD-LAYOUT.pdf |
Connection photo | Lead routing matches the lead-layout drawing; photos archived. |
| 6 | Run the dielectric withstand test; observe leakage current vs. 10 mA trip threshold. | Test Technician | TESTER-PROFILE.dat |
HIPOT-RAW.CSV |
Test completes full 60 s dwell; raw CSV stored. |
| 7 | Record serial number, applied voltage (2 120 V AC), dwell time (60 s), leakage current, ambient T/RH, technician ID. | Test Technician | HIPOT-RAW.CSV |
HIPOT-REPORT-XXXX.pdf |
Report signed by technician and QA reviewer. |
| 8 | Apply lot-acceptance sampling per ISO 2859-1:1999 (Normal, Level II, AQL 1.0 major / 2.5 minor). | QA Officer | QA-PLAN.pdf, ISO-2859-1-AQL-TABLE.pdf |
SAMPLING-RECORD.xlsx |
Sample size and Ac/Re values recorded; lot decision filed. |
| 9 | Tag PASS/FAIL; update unit status; stage for next corridor milestone. | Service Coordinator | HIPOT-REPORT-XXXX.pdf |
STATUS-UPDATE.csv |
Tag affixed; status reflects PASS or QUARANTINE. |
| 10 | Archive signed reports; notify customer per SLA; dispatch CN→PK if released. | Service Coordinator | HIPOT-REPORT-XXXX.pdf |
CUSTOMER-NOTICE.pdf |
Records archived; customer acknowledgement received. |
Test voltage, ramp time, dwell time, and trip-current values shall be taken from the OEM service manual for the specific EVSE battery pack model. The reference values below are for the CATL LFP BatteryPack (LFP-280Ah) per Service Manual Rev. 1.4 (2025-08-12), §5.1, and the allow-listed tester reference is IEC 61010-031:2015 Clause 6.7.
| Parameter | Reference value (CATL LFP-280Ah, Rev. 1.4 §5.1) | Typical range (indicative, other LFP packs) | Source |
|---|---|---|---|
| Test voltage (AC, dielectric withstand) | 2 120 V AC | 1 500 V AC – 2 500 V AC | CATL LFP-280Ah Service Manual Rev. 1.4 §5.1; tester per IEC 61010-031:2015 Clause 6.7 |
| Ramp time | 10 s | 5 s – 10 s | CATL LFP-280Ah Service Manual Rev. 1.4 §5.1 |
| Dwell time | 60 s | 60 s | CATL LFP-280Ah Service Manual Rev. 1.4 §5.1 |
| Trip current threshold | 10 mA | 5 mA – 20 mA | CATL LFP-280Ah Service Manual Rev. 1.4 §5.1 |
| Insulation resistance (pre-screen) | ≥ 100 MΩ at 500 V DC | ≥ 100 MΩ at 500 V DC | CATL LFP-280Ah Service Manual Rev. 1.4 §5.1 (pre-screen) |
Attribute sampling is applied per ISO 2859-1:1999, Normal inspection, Level II, AQL 1.0 for major defects and AQL 2.5 for minor defects. For a lot size of 26–50 units, ISO 2859-1 single-sampling plan at Level II, AQL 1.0 gives sample size n = 8, Ac = 1, Re = 2. Acceptance numbers (Ac) and rejection numbers (Re) are taken directly from the ISO 2859-1 single-sampling tables.
[Claim — Lot acceptance follows ISO 2859-1:1999 attribute plans using Ac/Re from the single-sampling tables | Src: ISO 2859-1:1999 Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection | URL: https://www.iso.org/search.html?q=2859 | accessed 2026-09-21 | Note: bot-walled lookup — cite full designation; do not guess /standard/ deep URLs]The following files must exist in the project folder before the unit is dispatched along the CN→PK corridor. Literal filenames are listed for traceability.
WO-XXXX.pdf — Work order issued by the customerINCOMING-CHECK.xlsx — Incoming inspection record (CN hub)PPE-CHECKLIST.pdf — Pre-shift PPE verificationCAL-CERT-HIPOT-XXX.pdf — Calibration certificate of the hipot testerOEM-LOTO-SEQUENCE.pdf — CATL LFP-280Ah Service Manual Rev. 1.4 §3.2 (LOTO extract)OEM-DATASHEET-PACK.pdf — CATL LFP-280Ah datasheet + Service Manual Rev. 1.4 §5.1 extractTESTER-PROFILE.dat — Programmed tester parameters (2 120 V AC / 10 s / 60 s / 10 mA)HIPOT-RAW.CSV — Raw measurement exportHIPOT-REPORT-XXXX.pdf — Signed test reportQA-PLAN.pdf — Project quality plan (ISO 2859-1:1999 Normal, Level II, AQL 1.0 / 2.5)ISO-2859-1-AQL-TABLE.pdf — Sampling table extract (Level II, AQL 1.0)SAMPLING-RECORD.xlsx — Filled attribute sampling record (n=8, Ac=1, Re=2)STATUS-UPDATE.csv — Unit status update (PASS / QUARANTINE)CUSTOMER-NOTICE.pdf — Customer notification per SLA| Milestone | Dependency | Indicative lead-time |
|---|---|---|
| A. Work order receipt (CN hub) | Customer PO confirmed | Day 0 |
| B. Incoming inspection & LOTO | A complete | Day 0 + 4 h |
| C. Hipot test execution (CATL LFP-280Ah profile) | B complete; calibration valid | Day 0 + 1 day |
| D. QA sampling & sign-off (ISO 2859-1:1999) | C complete | Day 1 + 4 h |
| E. Export preparation (CN customs) | D complete; commercial invoice, packing list, HS-coded | Day 2 (UNCERTAIN — depends on customs queue) |
| F. Multimodal transit CN → PK | E complete | indicative: 7–14 days, sea + road |
| G. PK customs clearance & delivery | F complete; FBR import documents | UNCERTAIN — depends on FBR processing window |
All cost slots below are indicative placeholders and are explicitly marked
UNCERTAIN until the project quote is issued. TradVolt does not publish hardcoded
unit prices on this public SOP page.
| Cost slot | Basis | Status |
|---|---|---|
| Labour — hipot test (per pack) | indicative | UNCERTAIN — quote on request |
| Calibration & tester depreciation | indicative | UNCERTAIN — quote on request |
| AQL re-test (failed lot) | indicative | UNCERTAIN — quote on request |
| CN→PK multimodal transit | indicative | UNCERTAIN — depends on Incoterm chosen (e.g., CIP, DAP) |
| Duties & taxes (PK import) | indicative | UNCERTAIN — see §9 |
| Item | HS code (proposed) | Rate |
|---|---|---|
| EVSE battery packs (lithium-ion, for electric vehicles) | 8507.60 — Lithium-ion accumulators (proposed; verify against current Pakistan PCT and China customs tariff) | PENDING — lookup |
| Replacement HV cabling / busbars | 8544.42 — Electric conductors, fitted with connectors | PENDING — lookup |
| Hipot test service (labour only) | Not classified as goods — service line item on commercial invoice | Not applicable |
Signed HIPOT-REPORT-XXXX.pdf, raw CSV exports, sampling records, and calibration
certificates are retained for the period required by the project SLA and by the OEM quality
agreement. Records are stored in the project folder under document control.
| Document | URL | Access date |
|---|---|---|
| IEC 61010-031:2015 (Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 031), Clause 6.7 | https://webstore.iec.ch/ | 2026-09-21 |
| UL 1434:2018 (Standard for Thermistor-Type Devices) | shopulstandards.com UL 1434 product page | 2026-09-21 |
| IEC 61851-1:2017 (Electric vehicle conductive charging system — Part 1: General requirements) | https://webstore.iec.ch/en/publication/33644 | 2026-09-21 |
| ISO 2859-1:1999 (Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by AQL for lot-by-lot inspection) | https://www.iso.org/search.html?q=2859 | 2026-09-21 |
| ICC Incoterms® 2020 (rules effective 2020-01-01) | https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/ | 2026-09-21 |
| FIATA (International Federation of Freight Forwarders Associations — multimodal documents) | https://fiata.org/ | 2026-09-21 |
| General Administration of Customs of the People's Republic of China (GACC) | http://english.customs.gov.cn/ | 2026-09-21 |
| Pakistan Customs (Federal Board of Revenue, FBR) | https://www.fbr.gov.pk/category/customs/145 | 2026-09-21 |
| CATL LFP BatteryPack (LFP-280Ah) — OEM service manual, Rev. 1.4 (2025-08-12), §3.2 / §5.1 | https://www.catl.com/en/ess/ | 2026-09-21 |
| USITC Harmonized Tariff Schedule search (HS lookup) | https://hts.usitc.gov/ | 2026-09-21 |
| WCO HS Nomenclature 2022 edition (chapter / note lookup) | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition | 2026-09-21 |
| TradVolt RFQ form (site path) | https://tradvolt.com/rfq/ | 2026-09-21 |
Get a tailored quote. Request Quote — replies in 48h Download Checklist (PDF, via RFQ form)