Use-case / TCO brief · Region: Australia · System: 2,000 kWp rooftop PV (LONGi Hi-MO 5m LR5-54HTH modules, Sungrow SG125HV inverters, K2 Systems S-Dome 6.10 mounting) · Horizon: 25 years · Currency: AUD · Evidence date: 2026-09-22
Verdict: For a 2,000 kWp rooftop PV system on a metropolitan Australian convention centre, the scenario model returns NPV = 8,726,119 AUD, discounted payback = 4.81 years, simple payback = 4.20 years, IRR = 0.2511, and LCOE = 0.0854 AUD/kWh (8.54 ¢/kWh) at a 5.0% real discount rate over a 25-year horizon. Verdict: GO (conditional on roof structural sign-off and a confirmed state-level feed-in tariff schedule). All financial figures on this page are reproduced verbatim from the COMPUTED TABLES; no other arithmetic is asserted.
| Item | Value |
|---|---|
| Equipment / location | 2,000 kWp rooftop PV — LONGi Hi-MO 5m LR5-54HTH (430–455 W) modules + Sungrow SG125HV (125 kW) string inverters + K2 Systems S-Dome 6.10 flat-roof mounting · metropolitan Australia |
| Horizon | 25 years |
| Discount rate (real) | 5.00 % |
| Evidence date | 2026-09-22 |
| Limitation | Model assumption, not measurement: self-consumption 75%; export value 0.08 AUD/kWh; year-12 inverter reserve treated as AUD-denominated capex lump-sum; residual_value.amount = 0; residual_value.year = n/a (residual not modelled) |
| NPV | 8,726,119 AUD |
| Discounted payback | 4.81 years |
| Simple payback | 4.20 years |
| IRR | 0.2511 |
| LCOE | 0.0854 AUD/kWh |
| Verdict | GO — conditional on structural certification and confirmed DNSP/offtake |
The 2,000 kWp system is sized for a large commercial rooftop and is built around one resolved module SKU and one resolved inverter SKU. Limits relied on by the model are stated up front; revisions and installation-specific torque values are confirmed at RFQ.
Module/inverter limits relied on by the model:
| Parameter | Value | Unit | Basis |
|---|---|---|---|
| System size (DC) | 2,000 | kWp | Site specification |
| Specific yield | 1,450 | kWh/kWp/yr | Model assumption within the APVI Australian PV yield reference band (https://pv-map.apvi.org.au/) [4] |
| Capex (turnkey) | 1,400 | AUD/kWp | Model assumption within CSIRO GenCost 2023-24 utility-scale solar capex band (https://www.csiro.au/en/research/energy/renewable-energy/GenCost) [5] |
| Annual O&M (fixed) | 28,000 | AUD/yr | Model assumption: 1.0% of capex per year, held flat in real terms |
| Inverter replacement reserve | 240,000 | AUD at year 12 | Model assumption: 120 AUD/kWp replacement provision (treated as lump-sum capex at year 12) |
| Module degradation | 0.5 | %/yr linear | Model assumption consistent with IEA PVPS Trends in PV Applications 2024 Tier-1 module benchmark (https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/) [6] |
| Electricity price (blended grid) | 0.28 | AUD/kWh | Model assumption within Eurostat EU/non-EU commercial electricity price band (used as transparency proxy; AU-specific retail series is lookup PENDING via AER) (https://ec.europa.eu/eurostat/databrowser) [7] |
| Electricity price escalation | 3.0 | %/yr real | Model assumption |
| Real discount rate | 5.0 | %/yr | Model assumption (commercial hurdle rate) |
| Self-consumption ratio | 75 | % of generation | Model assumption (convention-centre daytime load profile) |
| Exported energy value | 0.08 | AUD/kWh | Model assumption — typical state feed-in tariff band; state-dependent and to be confirmed |
| Analysis horizon | 25 | years | Standard PV asset life benchmark |
| Residual value | Not modelled | — | Model assumption: residual_value.amount = 0; residual_value.year = n/a |
| Metric | Value |
|---|---|
| Currency | AUD |
| Horizon (years) | 25 |
| Discount rate | 5.00 % |
| Total undiscounted cost (AUD) | 3,740,000.00 |
| Total discounted cost / PV of costs (AUD) | 3,328,271.43 |
| Total undiscounted benefit (AUD) | 22,739,017.05 |
| Total discounted benefit (AUD) | 12,054,390.32 |
| NPV (AUD) | 8,726,118.89 |
| IRR | 0.2511 |
| Simple payback (year) | 4.20 |
| Discounted payback (year) | 4.81 |
| LCOE (AUD/kWh) | 0.0854 |
| Year | Cost (AUD) | Benefit (AUD) | Net (AUD) | Discount factor | Discounted net (AUD) | Energy (kWh) |
|---|---|---|---|---|---|---|
| 0 | 2,800,000.00 | 0.0000 | -2,800,000.00 | 1.00 | -2,800,000.00 | 0.0000 |
| 1 | 28,000.00 | 667,000.00 | 639,000.00 | 0.9524 | 608,571.43 | 2,900,000.00 |
| 2 | 28,000.00 | 683,574.95 | 655,574.95 | 0.9070 | 594,625.80 | 2,885,500.00 |
| 3 | 28,000.00 | 700,561.79 | 672,561.79 | 0.8638 | 580,984.16 | 2,871,072.50 |
| 4 | 28,000.00 | 717,970.75 | 689,970.75 | 0.8227 | 567,640.64 | 2,856,717.14 |
| 5 | 28,000.00 | 735,812.32 | 707,812.32 | 0.7835 | 554,589.47 | 2,842,433.55 |
| 6 | 28,000.00 | 754,097.26 | 726,097.26 | 0.7462 | 541,824.95 | 2,828,221.38 |
| 7 | 28,000.00 | 772,836.57 | 744,836.57 | 0.7107 | 529,341.45 | 2,814,080.28 |
| 8 | 28,000.00 | 792,041.56 | 764,041.56 | 0.6768 | 517,133.40 | 2,800,009.88 |
| 9 | 28,000.00 | 811,723.80 | 783,723.80 | 0.6446 | 505,195.35 | 2,786,009.83 |
| 10 | 28,000.00 | 831,895.13 | 803,895.13 | 0.6139 | 493,521.88 | 2,772,079.78 |
| 11 | 28,000.00 | 852,567.73 | 824,567.73 | 0.5847 | 482,107.67 | 2,758,219.38 |
| 12 | 268,000.00 | 873,754.03 | 605,754.03 | 0.5568 | 337,306.51 | 2,744,428.28 |
| 13 | 28,000.00 | 895,466.82 | 867,466.82 | 0.5303 | 460,036.18 | 2,730,706.14 |
| 14 | 28,000.00 | 917,719.17 | 889,719.17 | 0.5051 | 449,368.64 | 2,717,052.61 |
| 15 | 28,000.00 | 940,524.49 | 912,524.49 | 0.4810 | 438,939.88 | 2,703,467.35 |
| 16 | 28,000.00 | 963,896.53 | 935,896.53 | 0.4581 | 428,744.98 | 2,689,950.01 |
| 17 | 28,000.00 | 987,849.36 | 959,849.36 | 0.4363 | 418,779.09 | 2,676,500.26 |
| 18 | 28,000.00 | 1,012,397.41 | 984,397.41 | 0.4155 | 409,037.46 | 2,663,117.76 |
| 19 | 28,000.00 | 1,037,555.49 | 1,009,555.49 | 0.3957 | 399,515.39 | 2,649,802.17 |
| 20 | 28,000.00 | 1,063,338.74 | 1,035,338.74 | 0.3769 | 390,208.28 | 2,636,553.16 |
| 21 | 28,000.00 | 1,089,762.71 | 1,061,762.71 | 0.3589 | 381,111.62 | 2,623,370.39 |
| 22 | 28,000.00 | 1,116,843.31 | 1,088,843.31 | 0.3418 | 372,220.95 | 2,610,253.54 |
| 23 | 28,000.00 | 1,144,596.87 | 1,116,596.87 | 0.3256 | 363,531.90 | 2,597,202.27 |
| 24 | 28,000.00 | 1,173,040.10 | 1,145,040.10 | 0.3101 | 355,040.19 | 2,584,216.26 |
| 25 | 28,000.00 | 1,202,190.15 | 1,174,190.15 | 0.2953 | 346,741.61 | 2,571,295.18 |
The COMPUTED TABLES above are the only computed numerical outputs on this page. The three scenario boxes below are verdict labels; financial values for the base case are taken from the COMPUTED TABLES, and the optimistic/pessimistic case values are model assumption bounds not derived from a separate run.
8541.43 — Photovoltaic cells assembled in modules or made up into panels (WCO HS Nomenclature 2022 edition chapter reference: https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition) [11].8504.40 — Static converters (PV string inverters).8544.42 — Other electric conductors, fitted with connectors (PV cabling assemblies).9406.00 — Prefabricated buildings (applicable only if integrated mounting structures are classified as such).Duty rate status: PENDING. Australian import duty depends on classification, country of origin and applicable Free Trade Agreement preferences. Confirm at the Australian Border Force working tariff portal at https://www.abf.gov.au/ [12]. For non-Australian destinations, use the relevant national tariff lookup: EU TARIC at https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en [13], USITC HTS at https://hts.usitc.gov/ [14], UK Global Tariff at https://www.trade-tariff.service.gov.uk/ [15].
Lookup instructions:
Disclaimer: general information only. Tradvolt does not provide legal, tax or customs advice. Confirm duty rates and classifications with a licensed customs broker or the Australian Border Force.
Request a formal quotation for a 2 MWp convention-centre PV system:
Submit an RFQ — tradvolt.com/rfq/
Reviewed · Generated by tradvolt.com editorial workflow · End of document.