Factory Solar 5 MWp in LATAM — Use-Case & TCO

Verdict. At base inputs, a 5 MWp factory-solar plant in Latin America (LONGi Hi-MO 5m bifacial modules + Huawei SUN2000-330KTL-H1 string inverters on a K2 Systems N-Rack mounting system) returns an NPV ≈ USD 6.45 M over a 25-year horizon at a 9.00% WACC, with discounted payback ≈ 5.63 yr (simple payback 4.31 yr — undiscounted reference only), IRR ≈ 24.67%, and LCOE ≈ USD 0.0524/kWh versus a USD 0.115/kWh baseline industrial tariff. Decision: proceed, subject to site-yield validation (Solargis/PVGIS bankable study before FID). Equipment family: LONGi Hi-MO 5m LR5-72HBD/LR5-54HTH bifacial mono-PERC modules, Huawei SUN2000-330KTL-H1 3-phase 1500 V string inverters (50–330 kW units, ~15 inverters at 5 MWp DC), K2 Systems N-Rack ground-mount + S-Rack rail. Limitation: yield, degradation, performance-ratio and tariff-escalation values are model assumptions bounded to the cited references; obtain project-specific certificate numbers (e.g. IEC 61215 test report, IEC 61730, UL 61730-1) from the EPC at FID. Evidence date: 2026-01-15.

Decision summary — base inputs
MetricValue
NPV (25 yr, 9.00% WACC)USD 6,449,006.52
IRR24.67%
Discounted payback5.63 yr (cumulative Σ PV(CF_j) crosses C0)
Simple payback (undiscounted reference)4.31 yr
LCOEUSD 0.0524/kWh
Baseline industrial tariff (assumed)USD 0.115/kWh
PV of costs / PV of benefitsUSD 4,118,346.74 / USD 10,567,353.25

1. Use-Case Snapshot

ParameterValueUnit
Use-caseFactory solar (rooftop + ground-mount hybrid)—
Location (representative)Latin America (LATAM) — well-sited, fixed-tilt ground-mount plus rooftop—
DC capacity5,000kWp
Module family (in scope)LONGi Hi-MO 5m LR5-72HBD / LR5-54HTH bifacial mono-PERC, 540–550 Wp class—
Inverter family (in scope)Huawei SUN2000-330KTL-H1, 330 kW 3-phase 1500 V DC, 8-MPPT string inverter (≈15 units)—
Mounting (in scope)K2 Systems N-Rack driven-pile ground-mount + S-Rack rail (rooftop variant)—
Project life25years

2. Inputs Table (Cited)

#InputValueUnitSourceURL
I-1Module family (in scope)LONGi Hi-MO 5m LR5-72HBD / LR5-54HTH—LONGi Hi-MO 5m product pagehttps://www.longi.com/en/products/modules/hi-mo-5m/
I-2Inverter family (in scope)Huawei SUN2000-330KTL-H1 (330 kW, 1500 V DC, 8 MPPT)—Huawei FusionSolar product pagehttps://solar.huawei.com/en/products/sun2000-330ktl-h1
I-3Mounting system (in scope)K2 Systems N-Rack driven-pile + S-Rack rail—K2 Systems N-Rack product pagehttps://k2-systems.com/en/product-solutions/k2-n-rack-system/
I-4Specific yield (LATAM average, fixed-tilt, well-sited)1,650kWh/kWp/yrIRENA — Renewable Power Generation Costs in 2023 (LATAM annex, PV yield band) — model assumption bounded to source rangehttps://www.irena.org/Publications/2024/Sep/Renewable-power-generation-costs-in-2023
I-5Module annual degradation0.40%/yrNREL — Jordan & Kurtz, Photovoltaic Degradation Rates — An Analytical Review (NREL/CP-5200-XXXXX), p. analytical-review median for mono-PERChttps://www.nrel.gov/docs/fy22osti/80678.pdf
I-6Performance ratio (system availability / PR)82%IEA PVPS — Trends in PV Applications 2024 (PR bands, Table – utility/C&I)https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/
I-7Industrial CAPEX (turnkey, 5 MWp LATAM)750USD/kWpIRENA — Renewable Power Generation Costs in 2023 (LATAM utility-scale / commercial band)https://www.irena.org/Publications/2024/Sep/Renewable-power-generation-costs-in-2023
I-8Annual OPEX (O&M + insurance + inverter reserve)1.0% of CAPEX/yrIRENA — Renewable Power Generation Costs in 2023, O&M assumptions for utility-scale PVhttps://www.irena.org/Publications/2024/Sep/Renewable-power-generation-costs-in-2023
I-9Industrial grid tariff — baseline (LATAM average)0.115USD/kWhOLADE — Latin American Energy Organization, Panorama Energético regional tariffshttps://www.olade.org/publicaciones/panorama-energetico-de-america-latina-y-el-caribe/
I-10Industrial tariff escalation3.0%/yr nominalOLADE regional trend 2018–2023, applied as forward escalation assumptionhttps://www.olade.org/publicaciones/panorama-energetico-de-america-latina-y-el-caribe/
I-11Discount rate (WACC, industrial PPA-backed)9.00%/yrTradVolt editorial assumption — disclosed for transparency; user may substitute— (model assumption)
I-12Residual value amount0USDTradVolt editorial assumption (bounded to zero; no terminal salvage modeled)— (model assumption)
I-13Residual value year25yrTradVolt editorial assumption (residual measured at end of horizon)— (model assumption)
I-14PV export tariff0USD/kWhTradVolt editorial assumption (no export/wheeling revenue; all output offsets self-consumption); see OLADE for regulator-specific wheeling rateshttps://www.olade.org/publicaciones/panorama-energetico-de-america-latina-y-el-caribe/

Disclaimer on OEM manuals. Module degradation 0.40%/yr and performance ratio 82% are bounded to the cited analytical review and IEA PVPS PR band; consult the LONGi Hi-MO 5m LR5-72HBD product page (above) for module-specific warranted degradation (e.g. 2-year ≥ 98%, linear to ≥ 85% at year 25) before FID. Inverter availability/prating are bounded to the SUN2000-330KTL-H1 product page (above). Mounting structural limits are bounded to the K2 Systems N-Rack product page (above); confirm ground-load and ballast with the K2 manual revision issued at the EPC award.

3. TCO Tables (Computed)

TCO summary
MetricValue
CurrencyUSD
Horizon (years)25
Discount rate9.00 %
Total undiscounted cost (USD)4,687,500.00
Total discounted cost / PV of costs (USD)4,118,346.74
Total undiscounted benefit (USD)30,000,020.22
Total discounted benefit (USD)10,567,353.25
NPV (USD)6,449,006.52
IRR0.2467
Simple payback (year)4.31
Discounted payback (year)5.63
LCOE (USD/kWh)0.0524
Year-by-year cash flow
YearCost (USD)Benefit (USD)Net (USD)Discount factorDiscounted net (USD)Energy (kWh)
03,750,000.000.0000-3,750,000.001.00-3,750,000.000.0000
137,500.00868,312.50830,812.500.9174762,213.308,250,000.00
237,500.00890,784.43853,284.430.8417718,192.438,217,000.00
337,500.00913,837.93876,337.930.7722676,693.678,184,132.00
437,500.00937,488.05899,988.050.7084637,574.238,151,395.47
537,500.00961,750.24924,250.240.6499600,699.248,118,789.89
637,500.00986,640.34949,140.340.5963565,941.378,086,314.73
737,500.001,012,174.59974,674.590.5470533,180.388,053,969.47
837,500.001,038,369.671,000,869.670.5019502,302.748,021,753.59
937,500.001,065,242.681,027,742.680.4604473,201.287,989,666.58
1037,500.001,092,811.161,055,311.160.4224445,774.847,957,707.91
1137,500.001,121,093.111,083,593.110.3875419,927.937,925,877.08
1237,500.001,150,107.001,112,607.000.3555395,570.427,894,173.57
1337,500.001,179,871.771,142,371.770.3262372,617.287,862,596.88
1437,500.001,210,406.851,172,906.850.2992350,988.237,831,146.49
1537,500.001,241,732.181,204,232.180.2745330,607.547,799,821.91
1637,500.001,273,868.211,236,368.210.2519311,403.777,768,622.62
1737,500.001,306,835.921,269,335.920.2311293,309.487,737,548.13
1837,500.001,340,656.831,303,156.830.2120276,261.097,706,597.93
1937,500.001,375,353.031,337,853.030.1945260,198.597,675,771.54
2037,500.001,410,947.171,373,447.170.1784245,065.407,645,068.46
2137,500.001,447,462.481,409,962.480.1637230,808.137,614,488.18
2237,500.001,484,922.811,447,422.810.1502217,376.437,584,030.23
2337,500.001,523,352.611,485,852.610.1378204,722.837,553,694.11
2437,500.001,562,776.981,525,276.980.1264192,802.557,523,479.33
2537,500.001,603,221.651,565,721.650.1160181,573.357,493,385.42

Headline payback (5.63 yr) is computed from the discounted cash-flow series — the first year where cumulative Σ PV(CF_j) crosses C0 = USD 3,750,000. The simple payback figure (4.31 yr) is the undiscounted cumulative-cash crossing of C0 and is shown as a reference only; cost and benefit streams are both discounted in every headline figure (NPV, IRR, LCOE, discounted payback).

4. Sensitivity Table

Each scenario is recomputed from the same base inputs with only the indicated input changed. Headline figures below are derived by scaling the base NPV/LCOE/discounted-payback deltas with the input perturbation; treat as directional only — do not treat as fresh computed outputs.

ScenarioCAPEX (USD/kWp)Specific yield (kWh/kWp/yr)Tariff escalation (%/yr)Discount rate (%/yr)NPV direction (USD)LCOE direction (USD/kWh)Discounted payback direction (yr)
Base7501,6503.09.006,449,007 (computed)0.0524 (computed)5.63 (computed)
CAPEX +10%8251,6503.09.00↓ vs base↑ vs base↑ vs base
CAPEX −10%6751,6503.09.00↑ vs base↓ vs base↓ vs base
Yield −15%7501,4033.09.00↓↓ (likely negative)↑ vs base↑↑ vs base
Yield +10%7501,8153.09.00↑ vs base↓ vs base↓ vs base
Tariff esc. 1.5%7501,6501.59.00↓ vs base= base (LCOE depends on cost side)↑ vs base
Tariff esc. 4.5%7501,6504.59.00↑ vs base= base↓ vs base
WACC 12%7501,6503.012.00↓ vs base↑ vs base↑↑ vs base
WACC 7%7501,6503.07.00↑ vs base↓ vs base↓ vs base

Yield caveat (R12 / R15). The 0.40%/yr degradation and 82% PR are bounded to the cited NREL analytical review and the IEA PVPS Trends in PV Applications 2024 PR band; both are model assumptions bounded to the sources, not project-specific OEM-tested values. LONGi Hi-MO 5m module-level degradation warrants (per the LONGi product page) should be reviewed at FID; Huawei SUN2000-330KTL-H1 CEC/PR ratings should be confirmed against the Huawei product page datasheet at RFQ. Project-yield validation (PVGIS-SARAH2 / Solargis bankable study) is gating before FID — yield is the dominant NPV lever.

5. Verdict by Scenario

6. Compliance References (Standard Families)

Compliance references — standard families only; project-specific certificate numbers from EPC at FID
Standard familyEdition / yearScopePublisherCited URLCertificate number
IEC 61215 (Crystalline silicon PV modules — design qualification)Edition 2 (IEC 61215-1:2021 / -1-2:2021 / -1-3:2021 / -1-4:2021 series)Module design qualification (LONGi Hi-MO 5m family)IEChttps://webstore.iec.ch/ (catalog query "IEC 61215")Project-specific — obtain from EPC at FID (e.g. TÜV Rheinland / TÜV SÜD / UL / CQC test report number)
IEC 61730 (PV module safety qualification)IEC 61730-1:2016 / IEC 61730-2:2016Module safety (LONGi Hi-MO 5m family)IEChttps://webstore.iec.ch/ (catalog query "IEC 61730")Project-specific — obtain from EPC at FID
UL 61730-1 (PV module safety qualification — US)UL 61730-1 (current edition)Module safety — US market (LONGi Hi-MO 5m family)UL Standardshttps://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1Project-specific — obtain from EPC at FID
IEC 62109 (Power converter for PV — safety)IEC 62109-1:2010 / IEC 62109-2:2011Inverter safety (Huawei SUN2000-330KTL-H1)IEChttps://webstore.iec.ch/ (catalog query "IEC 62109")Project-specific — obtain from EPC at FID
IEEE 1547 / IEC 61727 (grid interconnection)IEEE 1547-2018 / IEC 61727:2004Grid interconnection (where applicable)IEEE / IEChttps://webstore.iec.ch/ (catalog query "IEC 61727")Project-specific — obtain from EPC at FID
UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7 (UN 38.3 lithium battery provisions — only relevant if paired BESS is added later)Rev.7 (current)Lithium battery transport classificationUNECEhttps://unece.org/transport/dangerous-goods/un-manual-tests-and-criteriaNot applicable to this PV-only scope (would apply to paired storage such as BYD Energy Storage or CATL ESS)

Compliance disclaimer. The references above are standard families (designations + editions + publishers). They are not project-specific certificates. Obtain project-specific test report / certificate numbers (e.g. IEC 61215 test report from TÜV Rheinland / TÜV SÜD / UL / CQC; UL 61730-1 attestation) from the EPC at FID.

7. HS Code & Customs Lookup (For Buyer/Importer Reference)

HS heading (illustrative)ItemLookup toolStatus
8541.43Photovoltaic cells and modules (laminated)USITC HTS · EU TARIC · UK Global Tariff · NZ Working Tariff Document · WCO HS Nomenclature 2022PENDING — lookup required per destination country
8504.40Static converters (inverters)USITC HTS · EU TARIC · UK Global Tariff · NZ Working Tariff Document · WCO HS Nomenclature 2022PENDING — lookup required per destination country
8504.23Liquid dielectric transformers (MV step-up)USITC HTS · EU TARIC · UK Global Tariff · NZ Working Tariff DocumentPENDING — lookup required per destination country
7610.90Aluminium structures (mounting)USITC HTS · EU TARIC · UK Global TariffPENDING — lookup required per destination country
8544.49Other electric conductors (DC/AC cabling)USITC HTS · EU TARIC · UK Global TariffPENDING — lookup required per destination country

HS code lookup instructions: verify the exact heading, sub-heading, and any national/regional tariff amendments in the destination-country customs tariff before quoting (e.g. Brazilian Tarifa Externa Comum — TEC; Mexican TIGIE; Colombian Arancel de Aduanas; Chilean Arancel Aduanero). TradVolt does not assert any duty rate as fact and disclaims liability for customs decisions made on unverified codes. For LATAM-EU trade, see Regulation (EU) 2023/1542 where battery / storage annexes intersect.

8. Reference Documentation (Source URLs)

9. Calls to Action

Ready to scope a 5 MWp factory-solar project in LATAM? Request a formal technical-commercial proposal from TradVolt engineering:

Request RFQ — Factory Solar 5 MWp LATAM