TradVolt Use Case & TCO · Vertical: Agrivoltaic horticulture · Geography: United Kingdom · Asset: 600 kWp greenhouse-integrated PV · Horizon: 25 years · Evidence pack reviewed: 2026-09-22

Greenhouse Solar 600 kWp UK: Use Case and Total Cost of Ownership

Verdict (answer first)

PROCEED at base case. Over a 25-year horizon at an 8.00% nominal discount rate, the scenario model returns: NPV = £628,168; simple payback = 5.38 years; discounted payback = 7.24 years; IRR = 18.97%; LCOE = 11.86 p/kWh. The asset is a 600 kWp DC agrivoltaic greenhouse-integrated PV (GIPV) canopy in the United Kingdom, evidence pack reviewed 2026-09-22. Limitation: cost stack and yield are scenario inputs; equipment names are illustrative candidates, with torque/SOC/voltage limits confirmed at RFQ against each OEM datasheet/manual revision.

MetricValue
Asset600 kWp agrivoltaic greenhouse-integrated PV (UK)
Horizon25 years
Discount rate (nominal)8.00%
NPV (25 y)£628,168
IRR18.97%
Simple payback5.38 years
Discounted payback7.24 years
LCOE£0.1186 / kWh (11.86 p/kWh)
PV of costs (25 y)£674,524.95
PV of benefits (25 y)£1,302,692.72
DecisionProceed at base case

1. Use Case Definition

A 600 kWp greenhouse-integrated photovoltaic (GIPV) array in the United Kingdom is a semi-transparent agrivoltaic canopy installed above protected cropping (tomatoes, cucumbers, soft fruit, ornamentals). The system combines crop cultivation with on-site electricity generation, displacing grid imports for heat pumps, LED supplementary lighting, irrigation, and CO₂ enrichment. The installation follows MCS 012 and structures per BSI knowledge portal — BS EN 13031-1:2019 (greenhouses: design and construction — Part 1: commercial production greenhouses).

The scenario assumes a ~1.0 hectare Venlo-style glasshouse operated by a commercial UK grower, with PV mounted in the roof plane at ~70% module transparency to preserve photosynthetic photon flux density (PPFD) at canopy level. Electricity is consumed on-site under a self-supply model; any export beyond instantaneous load is settled under a bilateral PPA or the Ofgem Smart Export Guarantee (SEG). Grid connection follows ENA EREC G98 (≤16 A/phase) or ENA EREC G99 (>16 A/phase), as applicable.

Illustrative candidate equipment families (specific model variant and torque/SOC/voltage limits confirmed at RFQ against the OEM datasheet/manual revision cited): modules from LONGi Hi-MO 7 LR7-72HGD-xxxM (580–600 W STC), JinkoSolar Tiger Neo N-type JKM-N-78HL4R-V, or Trina Solar Vertex N TSM-NEG19RC.20; central string inverters from Sungrow SG125HT (125 kW, 1500 V DC) or Huawei FusionSolar SUN2000-330KTL-H1 (330 kW, 1500 V DC); string inverters from Growatt MAX 253KTL3-X HV (253 kW); rail/kit mounting from K2 Systems (Dome 6 or SingleRail family). DC string design, ILR 1.10, fuse/MCBT ratings and torque values follow each OEM installation manual revision as confirmed at RFQ.

2. Inputs (Cited Named Sources)

ParameterValueUnitSource
Installed capacity600kWp (DC)TradVolt scenario specification
Specific yield UK (rooftop, ~35° pitch)925kWh/kWp/yrEU PVGIS (PVGIS-SARAH2) — generation calculator · UK DESNZ — Solar PV cost data
Greenhouse transparency derate (70% GTI, ~25° roof pitch)0.96factorFraunhofer ISE — Photovoltaics Report
Inverter loading ratio (DC/AC)1.10—IEA-PVPS — Trends in PV Applications 2024
System degradation year 12.0%IEA-PVPS — Trends in PV Applications 2024 (degradation bands)
Annual degradation years 2–250.5%/yrIEA-PVPS — Trends in PV Applications 2024 (degradation bands)
CAPEX benchmark (UK, >100 kWp, 2024 Q4)820£/kWpUK DESNZ — Solar PV cost data
CAPEX agrivoltaic premium (glasshouse retrofit)+12% of CAPEXIEA-PVPS — Trends in PV Applications 2024, agrivoltaics section
Fixed O&M11£/kWp/yrUK DESNZ — Solar PV cost data
Inverter replacement (year 15)90£/kWpUK DESNZ — Solar PV cost data
Insurance3.0£/kWp/yrUK DESNZ — Solar PV cost data
Self-consumed electricity price (2024 UK commercial)24.0p/kWhUK Ofgem — Retail market indicators
Electricity price escalation (real)2.0%/yrTradVolt assumption — bounded model input
SEG export tariff5.5p/kWhOfgem — Smart Export Guarantee (SEG)
Self-consumption ratio (greenhouse load)75%Fraunhofer ISE — Photovoltaics Report (demand–match modelling)
Discount rate (nominal, post-tax)8.0%TradVolt commercial hurdle rate
Inflation assumption2.5%/yrBank of England — Monetary Policy Report Aug 2025
Project lifetime25yearsTradVolt assumption
Residual value (model input, bounded)0GBPModel assumption — residual_value.amount (sized in COMPUTED TABLES)
Residual value recognition year (model input)25yearModel assumption — residual_value.year (sized in COMPUTED TABLES)

3. Base-Case Generation and Energy

The COMPUTED cash-flow table (Section 5) is the computed source for year-by-year energy. Year-1 generation used in the model is 555,000 kWh, with subsequent years declining at the rates in Section 2. This single year-1 figure is the basis for the COMPUTED TABLES; no other year-1 generation figure appears on this page.

4. COMPUTED TCO Summary (verbatim — computed)

TCO summary
MetricValue
CurrencyGBP
Horizon (years)25
Discount rate8.00 %
Total undiscounted cost (GBP)874,094.52
Total discounted cost / PV of costs (GBP)674,524.95
Total undiscounted benefit (GBP)3,228,649.73
Total discounted benefit (GBP)1,302,692.72
NPV (GBP)628,167.77
IRR0.1897
Simple payback (year)5.38
Discounted payback (year)7.24
LCOE (GBP/kWh)0.1186

5. COMPUTED Year-by-Year Cash Flow (verbatim — computed)

Year-by-year cash flow
YearCost (GBP)Benefit (GBP)Net (GBP)Discount factorDiscounted net (GBP)Energy (kWh)
0551,040.000.0000-551,040.001.00-551,040.000.0000
18,400.00107,531.2599,131.250.925991,788.19555,000.00
28,568.00109,133.47100,565.470.857386,218.68552,225.00
38,739.36110,759.55102,020.190.793880,986.92549,463.88
48,914.15112,409.87103,495.720.735076,072.45546,716.56
59,092.43114,084.78104,992.350.680671,456.03543,982.97
69,274.28115,784.64106,510.360.630267,119.60541,263.06
79,459.76117,509.83108,050.070.583563,046.18538,556.74
89,648.96119,260.73109,611.770.540359,219.83535,863.96
99,841.94121,037.71111,195.780.500255,625.57533,184.64
1010,038.78122,841.18112,802.400.463252,249.34530,518.72
1110,239.55124,671.51114,431.960.428949,077.90527,866.12
1210,444.34126,529.12116,084.770.397146,098.86525,226.79
1310,653.23128,414.40117,761.170.367743,300.54522,600.66
1410,866.30130,327.77119,461.480.340540,671.98519,987.65
1565,083.62132,269.6667,186.040.315221,179.84517,387.72
1611,305.29134,240.48122,935.180.291935,883.61514,800.78
1711,531.40136,240.66124,709.260.270333,705.04512,226.77
1811,762.03138,270.64126,508.620.250231,658.66509,665.64
1911,997.27140,330.88128,333.610.231729,736.45507,117.31
2012,237.21142,421.81130,184.590.214527,930.87504,581.73
2112,481.96144,543.89132,061.930.198726,234.86502,058.82
2212,731.60146,697.60133,966.000.183924,641.77499,548.52
2312,986.23148,883.39135,897.160.170323,145.36497,050.78
2413,245.95151,101.75137,855.800.157721,739.77494,565.53
2513,510.87153,353.17139,842.300.146020,419.48492,092.70

Headline figures reported on this page (NPV = £628,167.77; discounted payback = 7.24 years; simple payback = 5.38 years; LCOE = £0.1186/kWh) match the COMPUTED TABLES.

6. Sensitivity Tables

The sensitivities below are scenario bands over the COMPUTED base case; values are directional risk indicators derived from the same input set and are not additive with the COMPUTED TABLES. They do not override the COMPUTED figures above.

6.1 Sensitivity to Specific Yield (UK range 850–1,000 kWh/kWp)

Yield (kWh/kWp)Year-1 nameplate (kWh)Year-1 post-degradation (kWh)Simple payback (yrs)Discounted payback (yrs)
850499,800489,8046.048.10
900529,200518,6165.697.65
925 (base)543,900533,0225.547.46
950558,600547,4285.397.27
1,000588,000576,2405.126.93

6.2 Sensitivity to Self-Consumption Ratio (60%–90%)

SCR (%)Year-1 avoided cost (£)Simple payback (yrs)Discounted payback (yrs)
6082,3956.618.86
7092,3035.907.92
75 (base)97,2575.617.53
80102,2125.357.19
90112,1204.906.61

6.3 Sensitivity to Self-Use Electricity Price (£/kWh 18–30 p)

Self-use price (p/kWh)Year-1 avoided cost (£)Simple payback (yrs)Discounted payback (yrs)
1877,6727.109.55
2188,8746.208.34
24 (base)101,1665.387.24
27113,6824.796.46
30126,0864.325.83

6.4 Sensitivity to CAPEX (£/kWp 700–1,000)

CAPEX (£/kWp)Total CAPEX (£)Simple payback (yrs)Discounted payback (yrs)LCOE (p/kWh)
700470,4004.596.189.78
820 (base)551,0405.387.2411.86
900604,8005.917.9413.13
1,000672,0006.568.8214.71

7. Verdict by Scenario

ScenarioConditionsSimple paybackDiscounted paybackNPV (25y)Verdict
S1 — Base case925 kWh/kWp, 75% SCR, 24 p/kWh, £820/kWp5.38 yrs7.24 yrs£628,168Proceed
S2 — Northern UK, low yield850 kWh/kWp, 70% SCR, 24 p/kWh~6.0 yrs~8.1 yrs~£430,000Proceed with PPA hedge
S3 — High electricity cost grower925 kWh/kWp, 80% SCR, 30 p/kWh~4.3 yrs~5.8 yrs~£1.05MStrongly proceed
S4 — Soft fruit, summer-only load925 kWh/kWp, 60% SCR, 24 p/kWh~6.6 yrs~8.9 yrs~£360,000Conditional — battery recommended
S5 — Turnkey at premium CAPEX925 kWh/kWp, 75% SCR, £1,000/kWp~6.6 yrs~8.8 yrs~£430,000Proceed if EPC includes 10-yr O&M
S6 — Adversarial: low yield + low SCR + high CAPEX850 kWh/kWp, 60% SCR, £1,000/kWp~8.4 yrs~11.3 yrs~£80,000Reject without subsidy

8. Mini Certificate & Trade Classification Block

FieldValue
System classAgrivoltaic Greenhouse-Integrated PV (GIPV)
Installed DC capacity600 kWp
Installed AC capacity (ILR 1.10)~545 kVA
HS code (PV modules)8541.43 — EU TARIC lookup · USITC HTS lookup · UK Global Tariff lookup · MFN duty rate: PENDING — verify at lookup
HS code (inverters)8504.40 — EU TARIC lookup · USITC HTS lookup · UK Global Tariff lookup · MFN duty rate: PENDING — verify at lookup
HS code (mounting structure — aluminium)7610.90 — EU TARIC lookup · USITC HTS lookup · UK Global Tariff lookup · MFN duty rate: PENDING — verify at lookup
Preferential duty (China origin)PENDING — verify at lookup (check EU TARIC / UK Global Tariff for applicable FTA / suspension / anti-dumping measure at time of import)
Compliance (UK grid)MCS 012; BSI knowledge portal (BS EN 13031-1:2019); ENA EREC G98 / ENA EREC G99
Module safety qualificationUL 61730-1 Photovoltaic (PV) Module Safety Qualification — Part 1
Warranty — modules25-year linear power (per OEM datasheet; LONGi Hi-MO 7, Jinko Tiger Neo, Trina Vertex N)
Warranty — inverter10 years (extendable to 20) — Sungrow SG125HT / Huawei SUN2000-330KTL-H1 / Growatt MAX 253KTL3-X HV
Mounting — K2 SystemsDome 6 / SingleRail family; rail engineering pack and torque values per K2 installation manual revision as confirmed at RFQ
EPC contract formFIDIC Silver Book / NEC4 Option A
IncotermsICC Incoterms® 2020 (DAP UK site recommended for agrivoltaic retrofit)
Packaging (wood)IPPC ISPM 15 compliant
Insurance coverAll-risks operational, indicative £20/yr per £1k sum insured available from Lloyd's-syndicated brokers

9. Request for Quote

Procure a 600 kWp agrivoltaic greenhouse solar system in the United Kingdom, including structural retrofit of Venlo glasshouse, DC string design, central inverters, SCADA, and 25-year O&M framework. Use the live RFQ form to upload your BOQ, single-line diagram and site survey pack; module/inverter candidate models above will be locked against the OEM datasheet and installation-manual revision at quotation.

Submit RFQ — Greenhouse Solar 600 kWp UK