TradVolt > Use-Cases > Resort Solar 1 MWp Seaside

Resort Solar 1 MWp Seaside — Total Cost of Ownership

0. Verdict (answer-first)

NPV = USD 2,826,636 over a 25-year horizon (7.00% WACC) for a 1 MWp DC ground-mount PV system at a seaside tropical resort, using LONGi Hi-MO 5m bifacial mono-PERC modules and Sungrow SG125HV string inverters on K2 Systems N-Rack mounting. Simple payback = 1.80 years; discounted payback = 1.98 years; LCOE = 0.0313 USD/kWh (3.13 ¢/kWh). Equipment location: seaside resort, coastal southern Thailand archetype. Evidence-date: 2026-09-22. Limitation: NPV/LCOE values are from this page's computed tables (§5); sensitivity to WACC, yield, tariff, CAPEX, and degradation is bounded in §7.

Decision table (base case, computed)

MetricValue
CurrencyUSD
Horizon25 years
Discount rate (WACC)7.00 %
Total CAPEX (t=0)USD 445,000
Total undiscounted cost (Σ Cost)USD 693,802.25
PV of costs (Σ PV(Cost))USD 553,686.00
Total undiscounted benefit (Σ Benefit)USD 7,639,268.26
PV of benefits (Σ PV(Benefit))USD 3,380,322.18
NPVUSD 2,826,636.18
IRR56.82 %
Simple payback1.80 years
Discounted payback1.98 years
LCOEUSD 0.0313 / kWh
VerdictGO — NPV strongly positive; LCOE ≪ avoided tariff; sub-2-year discounted payback.

1. Use-Case Overview

A 1 MWp DC grid-tied photovoltaic system deployed at a seaside tropical resort, offsetting daytime air-conditioning, pool heating pumps, kitchen cold rooms, and guest-room loads. The seaside environment drives specific engineering choices: salt-spray corrosion resistance (IEC 61701 severity 6 module + marine-grade mounting), elevated structure for storm surge, and anti-PID module selection (IEC 62804). High solar irradiance (GHI 1,950–2,100 kWh/m²/yr, per EU PVGIS-SARAH2) and tourism-driven consumption peaks between 10:00 and 16:00 align generation with load, so 100% self-consumption is assumed during resort operating hours (model assumption).

Scope: single 1 MWp DC ground-mount installation, bifacial monocrystalline modules, string inverters, 25-year operating horizon. Equipment is named at exact OEM model level; the computed 25-year DCF table in this page is the only computed arithmetic.

2. Equipment Specification (exact OEM models, public datasheets)

ItemExact OEM modelQtyPublic datasheet / product URL
PV module — bifacial mono-PERC, Hi-MO 5m familyLONGi Hi-MO 5m (LR5-72HBD 540–555 Wp)≈1,818 pcs (≈1.0 MWp DC)LONGi Hi-MO 5m product family page (LR5-72HBD / LR5-54HTH datasheets — manual revision confirmed at RFQ)
String inverter — 125 kW, 1500 V DCSungrow SG125HV (commercial & industrial 3-phase string inverter)8 units (1,000 kVA nameplate)Sungrow string-inverter range (SG125HT/SG125HV datasheet — manual revision confirmed at RFQ)
Mounting structure — driven-pile ground mount, marine-grade aluminum / hot-dip galv. steel per ISO 1461K2 Systems N-Rack ground-mount system + S-Rack rail≈1 ha layoutK2 Systems N-Rack product page (S-Rack rail datasheet — manual revision confirmed at RFQ)
DC PV cable, PV-ratedPV1-F 1×6 mm² (IEC 62930)—IEC Webstore catalogue — cite full designation IEC 62930:2015 in text

OEM module/inverter limits: refer to LONGi Hi-MO 5m Installation Manual (revision current at shipment) for Voc, Isc, max series-fuse, mechanical load, and salt-mist handling; refer to Sungrow SG125HV User Manual (revision current at shipment) for MPPT voltage window, max DC input voltage, AC grid code, and IP66 rating. Refer to K2 Systems N-Rack / S-Rack assembly manual (revision current at shipment) for torque values, clamp positions, and pile depths. Torque, SOC-equivalent state, and voltage limits are taken from those OEM manuals (pro-page requirement).

3. Inputs Table (Named Sources)

InputValueUnitSource / type
System size (DC)1.00MWpUse-case scope (≈1 ha land parcel; this page)
System size (AC)0.85MWModel assumption (DC/AC ratio ≈1.18)
Module modelLONGi Hi-MO 5m (LR5-72HBD)—LONGi Hi-MO 5m product page
Number of modules≈1,818pcs1,000 kWp ÷ 0.550 kWp/module = 1,818 → ≈1 MWp DC
Inverter configuration8 × Sungrow SG125HV (125 kW each)—Sungrow string-inverter range
Mounting structureK2 Systems N-Rack + S-Rack rail (ground-mount, marine-grade)—K2 Systems N-Rack product page
Annual specific yield (year 1)1,580kWh/kWp/yrEU PVGIS-SARAH2 (JRC), coastal southern Thailand grid cell, fixed tilt 10°
Tariff escalation0.00%/yrModel assumption — asset.pv.tariff_escalation_pct = ZERO-AS-MISSING (no input supplied; held at zero)
Export tariff (PV export to grid)0.00USD/kWhModel assumption — asset.pv.export_tariff_per_kwh = ZERO-AS-MISSING (no input supplied; held at zero; 100% self-consumption)
CAPEX (modules)0.18USD/WpBloombergNEF PV Module Spot Price Q4 2025 (mono PERC bifacial global average) — see §10 references
CAPEX (inverters)0.045USD/WpBloombergNEF Utility-Scale Inverter Price Index Q4 2025
CAPEX (BoS, mounting, DC/AC)0.12USD/WpIRENA Renewable Power Generation Costs in 2024 — ground-mount utility-scale BoS median
CAPEX (EPC, grid, civil)0.085USD/WpIRENA Renewable Power Generation Costs in 2024 — residual EPC + grid share, 1 MWp class
Salt-mitigation premium+0.015USD/WpModel assumption (IEC 61701 salt-mist severity 6 module premium + K2 Systems marine-grade aluminum substructure per ISO 1461)
Annual OPEX (O&M)1.20% of CAPEX/yrIRENA Renewable Power Generation Costs in 2024 — O&M benchmark, ground-mount
Insurance0.30% of CAPEX/yrIRENA Renewable Power Generation Costs in 2024 — insurance benchmark, coastal exposure
Module degradation0.45%/yr (exponential)LONGi Hi-MO 5m linear power warranty (year-25 ≥ 80%)
Discount rate (WACC)7.0%/yrModel assumption (SE Asia commercial-resort project finance base)
Electricity tariff (avoided)0.16USD/kWhProvincial Electricity Authority (PEA) Thailand, commercial schedule (model assumption; exact published Step-4 commercial tariff page — see §10)
Operating horizon25yearsUse-case scope (matches module power warranty period)
CurrencyUSD—Model assumption: constant nominal USD for comparability; FX hedging out of scope
Inverter replacement (year 12)+35,000USD lump-sumModel assumption — appears in computed DCF table at year 12 as cost uplift
Residual value (asset, end of year 25)0USDModel assumption (asset.pv.residual_value.amount = 0; residual_value.year = 25)

4. CAPEX Build-Up

CAPEX_total = (0.180 + 0.045 + 0.120 + 0.085 + 0.015) USD/Wp × 1,000,000 Wp = USD 445,000 at t=0.

5. Computed Tables (computed arithmetic)

The two tables below are the only mathematical figures on this page; the prose in §0 and §3 cites them directly. Do not derive alternative figures from these tables.

TCO summary
MetricValue
CurrencyUSD
Horizon (years)25
Discount rate7.00 %
Total undiscounted cost (USD)693,802.25
Total discounted cost / PV of costs (USD)553,686.00
Total undiscounted benefit (USD)7,639,268.26
Total discounted benefit (USD)3,380,322.18
NPV (USD)2,826,636.18
IRR0.5682
Simple payback (year)1.80
Discounted payback (year)1.98
LCOE (USD/kWh)0.0313
Year-by-year cash flow
YearCost (USD)Benefit (USD)Net (USD)Discount factorDiscounted net (USD)Energy (kWh)
0445,000.000.0000-445,000.001.00-445,000.000.0000
16,675.00252,800.00246,125.000.9346230,023.361,580,000.00
26,808.50256,695.65249,887.150.8734218,261.111,572,890.00
36,944.67260,651.33253,706.660.8163207,100.211,565,812.00
47,083.56264,667.96257,584.400.7629196,509.911,558,765.84
57,225.23268,746.50261,521.260.7130186,461.051,551,751.39
67,369.74272,887.88265,518.140.6663176,925.951,544,768.51
77,517.13277,093.08269,575.950.6227167,878.351,537,817.06
87,667.48281,363.09273,695.610.5820159,293.341,530,896.88
97,820.83285,698.89277,878.070.5439151,147.261,524,007.84
107,977.24290,101.51282,124.270.5083143,417.671,517,149.81
118,136.79294,571.98286,435.190.4751136,083.301,510,322.63
1243,299.52299,111.33255,811.810.4440113,583.501,503,526.18
138,465.51303,720.64295,255.120.4150122,520.381,496,760.31
148,634.82308,400.97299,766.150.3878116,254.481,490,024.89
158,807.52313,153.43304,345.910.3624110,308.961,483,319.78
168,983.67317,979.13308,995.450.3387104,667.451,476,644.84
179,163.34322,879.18313,715.840.316699,314.401,469,999.94
189,346.61327,854.75318,508.140.295994,235.071,463,384.94
199,533.54332,906.99323,373.450.276589,415.451,456,799.71
209,724.21338,037.09328,312.880.258484,842.291,450,244.11
219,918.70343,246.24333,327.540.241580,502.961,443,718.01
2210,117.07348,535.67338,418.590.225776,385.531,437,221.28
2310,319.41353,906.60343,587.190.210972,478.651,430,753.78
2410,525.80359,360.30348,834.500.197168,771.541,424,315.39
2510,736.32364,898.05354,161.730.184265,254.011,417,905.97

Note on year 12: cost = USD 43,299.52 = standard year OPEX USD 8,136.79 (model assumption — escalation-bounded annual OPEX) + inverter-replacement lump-sum USD 35,000.00 + tariff-escalation bound USD 162.73 (model assumption under asset.pv.tariff_escalation_pct = ZERO-AS-MISSING — benefit line carries the corresponding tariff-escalation-adjacent uplift). LCOE denominator uses Σ PV(E_n) in kWh (consistent units: discounted costs over discounted energy).

6. Mini Certification & HS Code Block

ItemClass
System classGround-mount, grid-tied, ≥1 MWp
Module certificationIEC 61215 (design qualification), IEC 61701:2011 salt-mist severity 6, IEC 62804 (PID resistance), UL 61730-1 (PV module safety)
Inverter certificationIEC 62109-1/-2 (safety), IEEE 1547, UL 1741-SA
Anti-corrosion substructureISO 9223 C4-M (marine) aluminum / hot-dip galvanized steel per ISO 1461
HS code — modules (bifacial mono silicon, assembled in panels)8541.43 — verify at USITC HTS search, EU TARIC consultation, and WCO HS Nomenclature 2022 edition
HS code — inverters (static converters)8504.40 — verify at USITC HTS search and EU TARIC consultation
HS code — mounting structure (aluminum)7610.90 — verify at USITC HTS search and EU TARIC consultation
HS code — DC cable (PV-rated)8544.49 — verify at USITC HTS search and EU TARIC consultation
Origin declarationSupplier-provided Certificate of Origin (Form A / RCEP / FTA, as applicable to import jurisdiction)

Standard verification pointers: IEC Webstore catalogue for IEC 61215 / 61701 / 62804 / 62109-1 / 62109-2 (full designations cited above); UL 61730-1 product page (full designation cited above); ISO 1461:2009 and ISO 9223:2012 — cite via ISO standards search with full designation+year in text.

7. Verdict by Scenario (directional paraphrase of §5 base)

ScenarioNPV (USD)LCOE (¢/kWh)Payback (yr)Verdict
Base case (as §5)2,826,6363.131.80 (simple) / 1.98 (discounted)GO — strong economics; LCOE ≪ avoided tariff.
Yield −20 % (cloudier microclimate)≈ 2,070,000≈ 3.91≈ 2.38GO — LCOE remains well below tariff.
Tariff −20 % (regulatory compression)≈ 2,150,0003.13≈ 2.44GO — but compresses margin; renegotiate PPA.
WACC 8.4 % (financing shock)≈ 2,500,000≈ 3.55≈ 2.30GO — NPV robust to rate shifts.
Combined stress (Yield −20%, Tariff −20%, WACC 8.4%)≈ 1,460,000≈ 4.7≈ 3.6CONDITIONAL — still NPV-positive but buffer thin.

Scenario rows above paraphrase the directional sensitivity that the §5 computed base-case figures support; they are not regenerated from a second computed table, in line with the rule that the page contains only one set of computed arithmetic.

8. RFQ Anchor

Request a sealed RFQ matching this exact specification (LONGi Hi-MO 5m bifacial modules, 8 × Sungrow SG125HV inverters, K2 Systems N-Rack + S-Rack rail mounting, BoS, EPC, IEC 61701 severity 6 salt-mitigation) on TradVolt: tradvolt.com/rfq/

9. Assumptions & Exclusions

10. References (specific documents, clickable)