tradvolt.com › Use-cases › Resort Solar 2 MWp LATAM (R9)

Resort Solar 2 MWp in LATAM — Use-case & Total Cost of Ownership

Verdict: at the scenario inputs stated below, a 2 MWp PV plant serving a tropical LATAM resort is economically viable — NPV ≈ USD 1,842,748, IRR ≈ 20.85 %, discounted payback ≈ 6.67 yr, simple payback ≈ 4.89 yr, LCOE ≈ 0.0698 USD/kWh (6.98 ¢/kWh) at a 9.00 % discount rate over a 25-year horizon. Equipment family: PV modules (LONGi Hi-MO 5 / Hi-MO 6, Jinko Tiger Neo, Trina Vertex S+) — confirm exact SKU at RFQ (LONGi, JinkoSolar, Trina Solar); string inverters (Sungrow SG110CX / SG250HX, Huawei SUN2000-330KTL, Growatt MAX 215KTL) — confirm SKU at RFQ (Sungrow, Huawei FusionSolar, Growatt); mounting (K2 Systems rail/kit, exact model and manual revision confirmed at RFQ). Location archetype: Caribbean coast / NE Brazil / Yucatán-type tropical resort corridor. Horizon: 25 years. Evidence date: 2026-09-22. Limitation: this is a use-case scenario, not a site-specific engineering, customs or financial commitment.

Decision table

Decision criterionResultReference
NPV (25 yr, 9 %)USD 1,842,748TCO summary table
IRR20.85 %TCO summary table
Simple payback4.89 yrTCO summary table
Discounted payback6.67 yrTCO summary table
LCOE0.0698 USD/kWh (6.98 ¢/kWh)TCO summary table
PV of costs (25 yr)USD 1,980,048.96TCO summary table
PV of benefits (25 yr)USD 3,822,797.35TCO summary table
Undiscounted total costUSD 2,663,848.39TCO summary table
Undiscounted total benefitUSD 10,358,701.85TCO summary table
VerdictGO at stated inputsscenario TCO model

1. Scenario inputs (bounded model assumptions)

ParameterValueBounded model assumption / status
DC capacity2.0 MWpModel assumption (project brief)
Location archetypeCaribbean coast / NE Brazil / Yucatán-type tropicalModel assumption (resort corridor)
Specific yield (year 1)1,500 kWh/kWp/yrModel assumption (regional median)
Performance ratio0.80Model assumption (ground-mount commercial)
Degradation0.5 %/yr linearModel assumption (mono-PERC tier-1 warranty median)
Tariff offset (grid)0.18 USD/kWhModel assumption (non-subsidised commercial band)
WACC / discount rate9.00 %Model assumption
Horizon25 yearsModel assumption (module performance warranty)
Residual value (end-of-horizon)amount = 0 USD (conservative; not credited)Model assumption (explicit bounded default)
Tariff escalation1.5 %/yr (embedded in benefit stream)Model assumption (explicit bounded default — asset.pv.tariff_escalation_pct)
Self-consumption share100 % (no export)Model assumption (explicit bounded default — asset.pv.self_consumption_pct)
Export tariff0 USD/kWh (no export)Model assumption (explicit bounded default — asset.pv.export_tariff_per_kwh)
Inverter replacementYear 12 lump capex line in year-12 cost columnModel assumption (drives the 206,814.48 year-12 cost entry)

2. CAPEX breakdown (USD)

All figures below reconcile to the Year-0 cost of USD 1,595,000.00 in the year-by-year cash flow table.

Line itemSubtotal (USD)
Monocrystalline modules (LONGi Hi-MO 5 / Hi-MO 6, Jinko Tiger Neo, Trina Vertex S+ family; exact SKU at RFQ)440,000
String inverters (Sungrow SG110CX / SG250HX, Huawei SUN2000-330KTL, Growatt MAX 215KTL family; exact SKU at RFQ)160,000
Mounting structure (K2 Systems rail/kit family; exact model + manual revision at RFQ)200,000
DC cabling, combiner, BoS electrical140,000
MV transformer + switchgear120,000
EPC + grid interconnection300,000
Civil, fencing, access road90,000
Developer fee + contingency (10 %)145,000
Total CAPEX (Year 0)1,595,000

3. TCO summary (computed — verbatim from scenario model)

TCO summary
MetricValue
CurrencyUSD
Horizon (years)25
Discount rate9.00 %
Total undiscounted cost (USD)2,663,848.39
Total discounted cost / PV of costs (USD)1,980,048.96
Total undiscounted benefit (USD)10,358,701.85
Total discounted benefit (USD)3,822,797.35
NPV (USD)1,842,748.39
IRR0.2085
Simple payback (year)4.89
Discounted payback (year)6.67
LCOE (USD/kWh)0.0698

4. Year-by-year cash flow (computed — verbatim from scenario model)

Year-by-year cash flow
YearCost (USD)Benefit (USD)Net (USD)Discount factorDiscounted net (USD)Energy (kWh)
01,595,000.000.0000-1,595,000.001.00-1,595,000.000.0000
128,000.00345,000.00317,000.000.9174290,825.693,000,000.00
228,560.00350,140.50321,580.500.8417270,667.872,985,000.00
329,131.20355,357.59326,226.390.7722251,906.632,970,075.00
429,713.82360,652.42330,938.600.7084234,445.252,955,224.62
530,308.10366,026.14335,718.040.6499218,193.692,940,448.50
630,914.26371,479.93340,565.670.5963203,068.182,925,746.26
731,532.55377,014.98345,482.440.5470188,990.722,911,117.53
832,163.20382,632.51350,469.310.5019175,888.732,896,561.94
932,806.46388,333.73355,527.270.4604163,694.632,882,079.13
1033,462.59394,119.90360,657.310.4224152,345.552,867,668.74
1134,131.84399,992.29365,860.450.3875141,782.942,853,330.39
12206,814.48405,952.18199,137.690.355570,800.372,839,063.74
1335,510.77412,000.86376,490.090.3262122,803.032,824,868.42
1436,220.99418,139.68381,918.690.2992114,287.822,810,744.08
1536,945.41424,369.96387,424.550.2745106,362.782,796,690.36
1637,684.31430,693.07393,008.760.251998,987.022,782,706.91
1738,438.00437,110.40398,672.400.231192,122.502,768,793.37
1839,206.76443,623.34404,416.580.212085,733.782,754,949.41
1939,990.89450,233.33410,242.430.194579,787.922,741,174.66
2040,790.71456,941.80416,151.090.178474,254.212,727,468.78
2141,606.53463,750.24422,143.710.163769,104.112,713,831.44
2242,438.66470,660.12428,221.460.150264,311.032,700,262.28
2343,287.43477,672.95434,385.520.137859,850.242,686,760.97
2444,153.18484,790.28440,637.100.126455,698.712,673,327.17
2545,036.24492,013.65446,977.410.116051,835.002,659,960.53

5. Standards & compliance (cited, not asserted)

6. HS code block — duty rate PENDING (lookup paths)

HS code (6-digit)DescriptionDuty rateLookup path
8541.43Photovoltaic cells assembled in modulesPENDINGEU TARIC | USITC HTS | UK Global Tariff
8504.40Static converters (inverters)PENDINGEU TARIC | USITC HTS
7308.20Towers, lattice masts and mounting structuresPENDINGEU TARIC | USITC HTS
8504.21Liquid dielectric transformers < 650 kVAPENDINGEU TARIC | USITC HTS

Lookup instructions: confirm the 8- or 10-digit national tariff line in the destination customs system (e.g. SUNAT, DIAN, SAT, SII, Aduanas MX, Japan Customs, Australian Border Force, South African Revenue Service, Ghana Revenue Authority, Uganda Revenue Authority), then read the bound or applied MFN duty. Cross-check any preferential rate under the EU–Mercosur agreement, the USMCA / Pacific Alliance framework or the corresponding bilateral. Disclaimer: the duty rates above are intentionally left PENDING; tradvolt.com does not assert any rate as fact and the importer of record remains responsible for the final classification, valuation and duty payment.

7. Freight, packaging and dangerous goods (forwarding notes)

8. Sources (every factual claim mapped to a specific document)

Claim on this pageSource / documentURL
Scenario is a tropical LATAM resort corridor; archetype (Caribbean coast / NE Brazil / Yucatán)IRENA, Renewable Capacity Statistics 2024 — Latin America & Caribbean regional chapterIRENA publications index (use for lookup)
Specific yield 1,500 kWh/kWp/yr (model assumption; corroborated against regional median)NASA POWER — Prediction of Worldwide Energy Resources (solar); Solcast — Global Solar Radiation Data (regional median, tropical coastal)NASA POWER / Solcast lookup (cite dataset + version in text at RFQ)
Performance ratio 0.80 (ground-mount commercial band)IEA-PVPS, Trends in PV Applications 2023 — performance ratio sectionIEA publications index (use for lookup)
Degradation 0.5 %/yr linear (module warranty median)LONGi / Jinko / Trina module datasheets (linear degradation warranty)LONGi | JinkoSolar | Trina Solar
Tariff offset 0.18 USD/kWh (commercial band, non-subsidised)OLADE, Energy Snapshot 2023 — Latin America & Caribbean commercial tariff bandsIEA / OLADE publications index (use for lookup)
WACC / discount rate 9.00 % (model assumption)Model assumption (bounded default — not a sourced fact)n/a (explicit bounded default)
HS code 8541.43 (PV cells in modules)EU TARIC; USITC HTS; UK Global TariffEU TARIC | USITC HTS | UK Global Tariff
HS code 8504.40 (static converters / inverters)EU TARIC; USITC HTSEU TARIC | USITC HTS
HS code 7308.20 (mounting structures)EU TARIC; USITC HTSEU TARIC | USITC HTS
HS code 8504.21 (liquid dielectric transformers < 650 kVA)EU TARIC; USITC HTSEU TARIC | USITC HTS
IEC 61215 / 61730 (module design qualification & safety)IEC Webstore (catalog)IEC Webstore (cite IEC 61215:2021 / IEC 61730-1:2016 + UL UL 61730-1 in text)
IEC 61724-1 (PV performance monitoring)IEC Webstore (catalog)IEC Webstore (cite IEC 61724-1:2021 in text)
IEC 62116 / IEEE 1547 (inverter anti-islanding, grid interconnection)IEC Webstore (catalog)IEC Webstore (cite IEC 62116:2014 in text)
Incoterms 2020 (risk transfer / delivery terms)ICC Incoterms 2020 — official rulesICC Incoterms 2020
Wood packaging complianceIPPC ISPM 15IPPC ISPMs
Freight forwarding documentsFIATAFIATA
EU Battery Regulation (forward-looking, if BESS is added)Regulation (EU) 2023/1542 (EU Battery Regulation)Regulation (EU) 2023/1542
Lithium battery UN 38.3 provisions (forward-looking)UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7UN Manual of Tests and Criteria
Module / inverter / mounting product families (SKU + datasheet to be named at RFQ)OEM landing pagesLONGi | JinkoSolar | Trina Solar | Sungrow | Huawei FusionSolar | Growatt | K2 Systems
Residual value, tariff escalation, self-consumption share, export tariffModel assumption (bounded defaults)n/a (explicit bounded defaults — residual_value.amount = 0; asset.pv.tariff_escalation_pct embedded in benefit stream; asset.pv.self_consumption_pct = 100; asset.pv.export_tariff_per_kwh = 0)

9. Scenario verdicts (qualitative — financial figures are settled by §3 and §4)

10. Call to action

Request a tailored EPC package and BoM for your resort site (modules, inverters, mounting structure with exact SKU and OEM manual revision, freight + Incoterms 2020 terms, and an indicative landed-cost table with the destination's applied MFN duty):

Open the TradVolt RFQ form