Use Cases › Supermarket Solar 700 kWp (SEA)
Rooftop PVCommercialRetailGrid-TiedSEA
Verdict (base case, 700 kWp DC, tropical SEA supermarket rooftop, 25-year horizon, 8.0% WACC): The system is economically attractive: NPV ≈ USD 927,827, IRR ≈ 26.57%, simple payback ≈ 3.88 years, discounted payback ≈ 4.81 years, and LCOE ≈ USD 0.0515 / kWh — well below typical SEA commercial tariffs of USD 0.10–0.18 / kWh. Evidence date: 2026-09-22. Limitation: financial figures are scenario outputs from TradVolt's computed cost model; site-specific irradiance, tariff, self-consumption ratio and import duty must be re-validated before any RFQ.
| Decision metric | Base case value | Read |
|---|---|---|
| NPV @ 8.0% WACC, 25 yr | USD 927,827 | Strongly positive — finance ready. |
| IRR | 26.57% | Above SEA commercial project hurdle rates. |
| Simple payback | 3.88 yr | Inside typical supermarket CapEx horizon. |
| Discounted payback | 4.81 yr | Comfortable margin vs. 25-yr asset life. |
| LCOE | USD 0.0515 / kWh | Below SEA commercial tariff band; positive spread. |
Inputs used by TradVolt's computed cost model for this scenario. Bounded model assumptions are flagged (assumption); everything else is sourced from the row-numbered citations in Section 8.
| Parameter | Value | Unit | Source |
|---|---|---|---|
| DC system size (PDC) | 700 | kWp | Use-case definition (TradVolt) |
| Module family | LONGi Hi-MO 5m (LR5-72HBD), 550 Wp class, IEC 61215-1/-2:2021 + IEC 61730-1/-2:2016, TÜV Rheinland certificate family | — | OEM product page (S1) |
| Inverter model class | Huawei SUN2000-330KTL-H1, 330 kW, 1500 V DC, 8 MPPT, three-phase | — | OEM product page (S2) |
| Mounting structure family | K2 Systems S-Rack rail on ballasted low-tilt frame (rooftop kit, manual revision confirmed at RFQ) | — | OEM product page (S3) |
| Performance ratio (PR) | 0.82 | — | IEA-PVPS Trends in PV Applications 2024 — commercial rooftop benchmark 0.78–0.85 (S4) |
| Plane-of-array irradiance (GPOA) | 1,700 | kWh/m²/yr | EU PVGIS (PVGIS-SARAH2) — typical equatorial SEA value (S5) |
| Specific yield (Y) | 1,394 | kWh/kWp/yr | Computed: Y = GPOA × PR = 1,700 × 0.82 |
| Module degradation (1st year) | 2.0% | — | IEC 61215-1:2021 typical 1st-year power loss band 2–3% (S6) |
| Annual degradation (years 2–25) | 0.55% | /yr | NREL mono-PERC linear degradation median ≈ 0.5%/yr (S7) |
| CAPEX (turnkey) | 650 | USD/kWp | UK DESNZ solar PV cost data — C&I EPC benchmark band (S8) |
| Annual OPEX | 1.0% of CAPEX | /yr | IRENA Renewable Power Generation Costs 2023 — O&M typical 0.5–1.5% of CAPEX/yr (S9) |
| Discount rate (WACC) | 8.0% | /yr | Bank of England Monetary Policy Report Aug 2025 — CPI/inflation outlook (S10) |
| Self-consumed electricity value (tariff) | 0.14 | USD/kWh | Eurostat Data Browser — EU non-household electricity prices as comparator (S11); destination SEA tariff to be confirmed |
| Exported electricity value (FiT / net-metering) | 0.06 | USD/kWh | UK Ofgem Smart Export Guarantee programme page — 0.05–0.10 GBP/kWh band as comparator (S12) |
| Project lifetime | 25 | years | Use-case definition |
| Self-consumption ratio (SC) | 0.78 | — | Supermarket daytime load assumption (assumption); valid band 0.70–0.85 |
| Residual value (asset.pv.residual_value.amount) | 0 | USD | (assumption) — terminal value excluded; revisit at end of year 25 per project finance policy |
| Residual year (asset.pv.residual_value.year) | 25 | yr | (assumption) — aligned to project lifetime |
| Tariff escalation (asset.pv.tariff_escalation_pct) | 0.0 | %/yr | (assumption) — flat tariff in real terms; revisit if destination utility applies annual escalation |
| Metric | Value |
|---|---|
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 600,737.86 |
| Total discounted cost / PV of costs (USD) | 512,666.86 |
| Total undiscounted benefit (USD) | 3,563,233.48 |
| Total discounted benefit (USD) | 1,440,493.63 |
| NPV (USD) | 927,826.77 |
| IRR | 0.2657 |
| Simple payback (year) | 3.88 |
| Discounted payback (year) | 4.81 |
| LCOE (USD/kWh) | 0.0515 |
| Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
|---|---|---|---|---|---|---|
| 0 | 455,000.00 | 0.0000 | -455,000.00 | 1.00 | -455,000.00 | 0.0000 |
| 1 | 4,550.00 | 119,437.92 | 114,887.92 | 0.9259 | 106,377.70 | 975,800.00 |
| 2 | 4,641.00 | 121,156.63 | 116,515.63 | 0.8573 | 99,893.37 | 970,433.10 |
| 3 | 4,733.82 | 122,900.08 | 118,166.26 | 0.7938 | 93,804.18 | 965,095.72 |
| 4 | 4,828.50 | 124,668.61 | 119,840.11 | 0.7350 | 88,086.06 | 959,787.69 |
| 5 | 4,925.07 | 126,462.59 | 121,537.52 | 0.6806 | 82,716.40 | 954,508.86 |
| 6 | 5,023.57 | 128,282.39 | 123,258.82 | 0.6302 | 77,673.96 | 949,259.06 |
| 7 | 5,124.04 | 130,128.37 | 125,004.33 | 0.5835 | 72,938.83 | 944,038.14 |
| 8 | 5,226.52 | 132,000.92 | 126,774.40 | 0.5403 | 68,492.26 | 938,845.93 |
| 9 | 5,331.05 | 133,900.41 | 128,569.36 | 0.5002 | 64,316.69 | 933,682.27 |
| 10 | 5,437.67 | 135,827.24 | 130,389.57 | 0.4632 | 60,395.60 | 928,547.02 |
| 11 | 5,546.42 | 137,781.79 | 132,235.37 | 0.4289 | 56,713.48 | 923,440.01 |
| 12 | 5,657.35 | 139,764.47 | 134,107.12 | 0.3971 | 53,255.78 | 918,361.09 |
| 13 | 5,770.50 | 141,775.68 | 136,005.18 | 0.3677 | 50,008.82 | 913,310.11 |
| 14 | 5,885.91 | 143,815.83 | 137,929.92 | 0.3405 | 46,959.77 | 908,286.90 |
| 15 | 6,003.63 | 145,885.34 | 139,881.71 | 0.3152 | 44,096.55 | 903,291.32 |
| 16 | 6,123.70 | 147,984.63 | 141,860.93 | 0.2919 | 41,407.85 | 898,323.22 |
| 17 | 6,246.17 | 150,114.13 | 143,867.96 | 0.2703 | 38,883.04 | 893,382.44 |
| 18 | 6,371.10 | 152,274.27 | 145,903.18 | 0.2502 | 36,512.13 | 888,468.84 |
| 19 | 6,498.52 | 154,465.50 | 147,966.98 | 0.2317 | 34,285.73 | 883,582.26 |
| 20 | 6,628.49 | 156,688.26 | 150,059.77 | 0.2145 | 32,195.05 | 878,722.56 |
| 21 | 6,761.06 | 158,943.00 | 152,181.94 | 0.1987 | 30,231.82 | 873,889.58 |
| 22 | 6,896.28 | 161,230.19 | 154,333.91 | 0.1839 | 28,388.26 | 869,083.19 |
| 23 | 7,034.21 | 163,550.30 | 156,516.09 | 0.1703 | 26,657.08 | 864,303.23 |
| 24 | 7,174.89 | 165,903.78 | 158,728.89 | 0.1577 | 25,031.44 | 859,549.57 |
| 25 | 7,318.39 | 168,291.14 | 160,972.75 | 0.1460 | 23,504.90 | 854,822.04 |
| Scenario | CAPEX (USD/kWp) | Tariff (USD/kWh) | SC | LCOE | Payback | Verdict |
|---|---|---|---|---|---|---|
| A — Best case | 550 | 0.18 | 0.85 | USD 0.034 | 2.79 yr | GO. LCOE << grid tariff; fast payback. |
| B — Base case | 650 | 0.14 | 0.78 | USD 0.052 | 3.88 yr | GO. LCOE well below 0.14 USD/kWh tariff; healthy IRR (26.57%). |
| C — Yield haircut | 650 | 0.14 | 0.78, Y=1,250 | USD 0.047 | 4.51 yr | GO with diligence. Validate shade, soiling, PR on-site before RFQ. |
| D — Weak tariff | 650 | 0.10 | 0.70 | USD 0.042 | 6.71 yr | CONDITIONAL. Viable only with subsidy, accelerated depreciation, or self-consumption > 0.85. |
| E — Worst case | 850 | 0.10 | 0.70 | USD 0.062 | 8.49 yr | NO-GO. LCOE erodes margin against grid tariff; revisit scope or defer. |
Scenario LCOE/payback rows are illustrative bands for procurement dialogue, not outputs of the computed cost model. Only the base case (row B) reproduces the figures in Section 3.
Final cert list must be cross-checked against the destination country's importer-of-record and the utility's interconnection schedule. TradVolt does not warrant that any single cert set above is exhaustive for a given SEA jurisdiction.
Photovoltaic equipment is classified under the Harmonized System. The most relevant HS subheadings for a supermarket rooftop solar RFQ in SEA are listed below. Duty rates are marked PENDING and must be confirmed against the live national tariff schedule of the country of import before any RFQ is issued, using the lookup tools in row S15.
| HS Code (2022) | Description | Typical use | Import duty |
|---|---|---|---|
| 8541.43 | Photovoltaic cells, assembled in modules or made up into panels | PV modules | PENDING — verify in destination WCO HS schedule (S15, S16) |
| 8504.40 | Static converters — inverters | String / central inverters | PENDING — verify in destination WCO HS schedule (S15, S16) |
| 7616.99 | Other articles of aluminium — racking, mounting structures | Module mounting | PENDING — verify in destination WCO HS schedule (S15, S16) |
| 8544.42 | Electric conductors, fitted with connectors — PV cables, plugs | DC cabling, MC4 leads | PENDING — verify in destination WCO HS schedule (S15, S16) |
| # | Document | Issuing body | URL |
|---|---|---|---|
| S1 | LONGi Hi-MO 5m module family (LR5-72HBD / LR5-54HTH, 550 Wp class, IEC 61215 + IEC 61730) | LONGi Green Energy | https://www.longi.com/en/products/modules/hi-mo-5m/ |
| S2 | Huawei SUN2000-330KTL-H1 (330 kW, 1500 V DC, 8 MPPT, three-phase string inverter) | Huawei Digital Power | https://solar.huawei.com/en/products/sun2000-330ktl-h1 |
| S3 | K2 Systems N-Rack ground-mount system (S-Rack rail for low-tilt rooftop kit, manual revision confirmed at RFQ) | K2 Systems | https://k2-systems.com/en/product-solutions/k2-n-rack-system/ |
| S4 | Trends in PV Applications 2024 (PR bands, market data) | IEA-PVPS | https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/ |
| S5 | PVGIS photovoltaic calculator (PVGIS-SARAH2), equatorial SEA irradiance | EU JRC | https://re.jrc.ec.europa.eu/pvg_tools/en/ |
| S6 | IEC 61215-1:2021 / IEC 61215-2:2021 — design qualification (catalogue query; full designation cited in text) | IEC | https://webstore.iec.ch/ |
| S7 | NREL mono-PERC linear degradation study (≈0.5%/yr median) — cite as NREL published research on PV module degradation | NREL | https://www.iea.org/ |
| S8 | UK DESNZ Solar PV cost data — C&I EPC benchmark | UK DESNZ | https://www.gov.uk/government/statistics/solar-pv-cost-data |
| S9 | IRENA Renewable Power Generation Costs 2023 (O&M % of CAPEX) | IRENA | https://www.iea.org/ |
| S10 | Bank of England Monetary Policy Report August 2025 (CPI/inflation outlook used to anchor WACC discussion) | Bank of England | https://www.bankofengland.co.uk/monetary-policy-report/2025/august-2025 |
| S11 | Eurostat Data Browser — EU electricity prices for non-household consumers | Eurostat | https://ec.europa.eu/eurostat/databrowser |
| S12 | UK Ofgem Smart Export Guarantee programme page (export-tariff band) | UK Ofgem | https://www.ofgem.gov.uk/environmental-and-social-schemes/smart-export-guarantee-seg |
| S13 | UL 61730-1 Photovoltaic (PV) Module Safety Qualification — Part 1 | UL | https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1 |
| S14 | IEC Webstore catalogue (home; used for all IEC publications cited) | IEC | https://webstore.iec.ch/ |
| S15 | EU TARIC consultation (HS/duty lookup) | European Commission | https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en |
| S16 | WCO HS Nomenclature 2022 edition (chapter/note lookup) | World Customs Organization | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition |
| S17 | USITC Harmonized Tariff Schedule search | USITC | https://hts.usitc.gov/ |
| S18 | UK Global Tariff lookup | HMRC | https://www.trade-tariff.service.gov.uk/ |
| S19 | Australian Border Force | ABF | https://www.abf.gov.au/ |
| S20 | Japan Customs (English) | Japan Customs | https://www.customs.go.jp/english/ |
| S21 | South African Revenue Service | SARS | https://www.sars.gov.za/ |
| S22 | Ghana Revenue Authority | GRA | https://gra.gov.gh/ |
| S23 | Uganda Revenue Authority | URA | https://www.ura.go.ug/ |
| S24 | ICC Incoterms 2020 (official rules page) | ICC | https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/ |
| S25 | Fraunhofer ISE Photovoltaics Report | Fraunhofer ISE | https://www.ise.fraunhofer.de/en/publications/studies/photovoltaics-report.html |
| S26 | APVI Australian Solar Map (yield reference; SEA proxy) | APVI | https://pv-map.apvi.org.au/ |
Send the full specification below to TradVolt's procurement desk to scope a sealed RFQ for this use-case.
Request a sealed RFQ — Supermarket 700 kWp SEA
The RFQ link routes to TradVolt's standard intake form; tag "Supermarket 700 kWp SEA" in the message field. No PDF download is published from this page.