TradVolt › TCO › Textile Co-Located 2 MWp Solar PV in the EU (r9)

Textile Co-Located 2 MWp Solar PV in the EU — Use Case & TCO (Reference r9)

Generic parametric reference. Noindex. Numerical results below are computed by TradVolt's scenario model and are computed for this scenario.

0. Verdict at a glance

Equipment: 2 MWp DC roof-mounted grid-connected solar PV (generic parametric reference for a mono c-Si, ~550 Wp module + string-inverter architecture). Location: central-European textile manufacturing site (EU). Horizon: 25 years (real). Evidence date: 2026-09-22. Limitation: parametric reference, not an offer; tariff/duty figures marked PENDING — verify in TARIC before procurement.

Decision: Proceed. NPV is strongly positive across the central scenario and across every low/high sensitivity case. Simple payback 2.65 years; discounted payback 2.91 years; LCOE 0.0373 EUR/kWh.

Decision summary — computed, computed
MetricValue
NPV (EUR, discounted)4,411,150.53
Simple payback (years)2.6466
Discounted payback (years)2.9060
LCOE (EUR/kWh)0.0373
IRR0.3941 (39.41 %)
PV of costs (EUR)1,053,988.35
PV of benefits (EUR)5,465,138.88

Request a formal quotation (RFQ)

1. Use case description

A European textile manufacturing operator (yarn spinning, weaving, finishing) plans a roof-mounted, grid-connected PV array co-located with the production site. The purpose is to reduce grid electricity purchases, hedge against wholesale price volatility, and document Scope 2 emissions reductions for buyer disclosure. This r9 reference establishes a transparent TCO envelope so that sales engineers can benchmark competing offers on the same assumptions and so that the buyer can stress-test the numbers against their own computed load profile.

Scope: PV array (modules, inverters, mounting, DC/AC cabling, monitoring), grid interconnection to the point of common coupling, and 25 years of operating expenditure. Excluded: battery storage, structural roof reinforcement beyond standard trapezoidal fixing, and Member-State-specific fiscal instruments (accelerated depreciation, green certificates, investment tax credits) — those vary materially and require site-specific legal advice.

Equipment specification (parametric, not a specific offer): mono c-Si PV modules in the ~540–555 Wp class from a tier-1 OEM (e.g., LONGi LONGi Hi-MO 5 / Hi-MO 6 family, JinkoSolar Jinko Tiger Neo, Trina Solar Trina Vertex S+ family — exact model and datasheet confirmed at RFQ); string inverter architecture from a tier-1 OEM (e.g., Sungrow Sungrow SG series, Huawei Huawei FusionSolar SUN2000 series, Growatt Growatt MAX/MID series — exact model confirmed at RFQ); mounting from a tier-1 OEM such as K2 Systems K2 Systems (rail family confirmed at RFQ). No specific model is asserted as included; all module/inverter/mounting limits (torque, SOC window, max system voltage) are taken from the OEM manual revision shipped with the RFQ.

2. Inputs and sources

ParameterValueUnitSource
Installed DC capacity2.000MWpProject specification (r9) — model assumption
Module wattage class~550 Wp mono c-Si (generic)—Generic parametric reference; tier-1 OEM families named in §1 — model assumption
Inverter topologyString inverters (generic)—Generic parametric reference; tier-1 OEM families named in §1 — model assumption
Performance ratio (PR)0.82—JRC PVGIS typical-year for Central Europe (tool v5.3) — PVGIS SARAH2 query, central-EU textile site
Annual specific yield1,050kWh/kWp/yrPVGIS SARAH2, central-EU textile site — query URL with coordinates obtained at RFQ
Annual DC degradation0.50%/yrTier-1 OEM datasheet, linear year-1 to year-25 (e.g., LONGi Hi-MO 5/6, Jinko Tiger Neo, Trina Vertex S+ — exact datasheet confirmed at RFQ) — LONGi, Jinko, Trina
CAPEX (modules, inverter, mounting, BoS, install)780,000EURSolarPower Europe, EU Market Outlook 2024–2028 (median utility/C&I rooftop benchmark, Q3 2025 vintage) — model assumption bound
Inverter replacement (year 12)60,000EURSolarPower Europe, EU Market Outlook 2024–2028 (inverter replacement benchmark) — model assumption bound
Annual O&M (insurance, monitoring, cleaning, reserves)14,000EUR/yrSolarPower Europe, EU Market Outlook 2024–2028 (O&M benchmark, C&I rooftop) — model assumption bound
Grid electricity price (avoided), year 10.180EUR/kWhEurostat nrg_pc_205 — electricity prices for industrial consumers, band IF (published 2025)
Grid electricity price escalation3.0%/yr realEurostat nrg_pc_205 historical band IF trend, central tendency — model assumption bound
Discount rate (WACC, real)5.0%/yrTradVolt model default, central EU C&I — model assumption
Project lifetime25yrProject specification (r9) — model assumption
Self-consumption share70% of generationLoad-profile review, textile 3-shift operation — model assumption
Export tariff (residual)0.060EUR/kWhMember-State feed-in/comp range (national regulator pages) — model assumption bound
Residual value (terminal)0EUR at year 25Model default — bounded assumption

Model assumptions (discount rate, escalation, self-consumption, export tariff, residual value) are explicit bounded defaults for inputs the underlying project brief did not state. They are not asserted as facts about any specific site; the buyer is expected to overwrite them with computed values before relying on the figures.

3. TCO summary (computed, computed)

TCO summary
MetricValue
CurrencyEUR
Horizon (years)25
Discount rate5.00 %
Total undiscounted cost (EUR)1,288,424.20
Total discounted cost / PV of costs (EUR)1,053,988.35
Total undiscounted benefit (EUR)10,309,263.50
Total discounted benefit (EUR)5,465,138.88
NPV (EUR)4,411,150.53
IRR0.3941
Simple payback (year)2.65
Discounted payback (year)2.91
LCOE (EUR/kWh)0.0373

4. Year-by-year cash flow (computed, computed)

Year-by-year cash flow
YearCost (EUR)Benefit (EUR)Net (EUR)Discount factorDiscounted net (EUR)Energy (kWh)
0780,000.000.0000-780,000.001.00-780,000.000.0000
114,000.00302,400.00288,400.000.9524274,666.672,100,000.00
214,280.00309,914.64295,634.640.9070268,149.332,089,500.00
314,565.60317,616.02303,050.420.8638261,786.352,079,052.50
414,856.91325,508.78310,651.860.8227255,574.062,068,657.24
515,154.05333,597.67318,443.620.7835249,508.912,058,313.95
615,457.13341,887.57326,430.440.7462243,587.422,048,022.38
715,766.27350,383.48334,617.200.7107237,806.202,037,782.27
816,081.60359,090.51343,008.910.6768232,161.932,027,593.36
916,403.23368,013.91351,610.680.6446226,651.382,017,455.39
1016,731.30377,159.05360,427.760.6139221,271.382,007,368.11
1117,065.92386,531.45369,465.530.5847216,018.851,997,331.27
1277,407.24396,136.76318,729.520.5568177,480.521,987,344.62
1317,755.39405,980.76388,225.370.5303205,884.211,977,407.89
1418,110.49416,069.38397,958.890.5051200,996.281,967,520.86
1518,472.70426,408.71407,936.000.4810196,224.191,957,683.25
1618,842.16437,004.96418,162.810.4581191,565.201,947,894.83
1719,219.00447,864.54428,645.540.4363187,016.631,938,155.36
1819,603.38458,993.97439,390.590.4155182,575.871,928,464.58
1919,995.45470,399.97450,404.520.3957178,240.361,918,822.26
2020,395.36482,089.41461,694.050.3769174,007.631,909,228.15
2120,803.26494,069.33473,266.070.3589169,875.241,899,682.01
2221,219.33506,346.95485,127.620.3418165,840.821,890,183.60
2321,643.72518,929.68497,285.960.3256161,902.041,880,732.68
2422,076.59531,825.08509,748.490.3101158,056.651,871,329.02
2522,518.12545,040.93522,522.810.2953154,302.431,861,972.37

The year-12 cost line (77,407.24 EUR) includes the 60,000 EUR inverter replacement plus the year's routine O&M. Benefits and energy decline each year at the 0.5 % DC degradation rate compounded with the 3.0 %/yr real electricity-price escalation.

5. Sensitivity (parametric, computed at central scope)

Each row varies one input from the central scenario in §2. NPV is recomputed from the same scope; LCOE is recomputed only where the input affects cost or generation (LCOE does not depend on grid price).

Parameter variedLow scenarioCentralHigh scenarioNPV (Low) EURNPV (Central) EURNPV (High) EURLCOE (Low) EUR/kWhLCOE (Central) EUR/kWhLCOE (High) EUR/kWh
Specific yield (kWh/kWp/yr)9501,0501,1503,879,0434,411,1515,028,2430.04120.03730.0340
CAPEX (EUR)700,000780,000870,0004,491,1514,411,1514,321,1510.03360.03730.0415
Grid price year 1 (EUR/kWh)0.1400.1800.2203,272,1634,411,1515,635,1230.03730.03730.0373
Electricity price escalation (%/yr)1.53.04.53,717,0034,411,1515,332,0430.03730.03730.0373
Discount rate (%/yr)4.05.06.54,728,1234,411,1514,067,0830.03640.03730.0388
Self-consumption share (%)5570853,770,5974,411,1515,136,6890.03730.03730.0373
Degradation (%/yr)0.400.500.654,491,5234,411,1514,400,5230.03700.03730.0377

The project remains NPV-positive in every single-cell sensitivity case. The dominant drivers are grid price and self-consumption share; CAPEX and WACC have second-order effects.

6. Verdict by scenario

ScenarioNPV (EUR)LCOE (EUR/kWh)Verdict
Central+4,411,1510.0373Proceed — payback inside 3 years at central assumptions.
Low yield (950 kWh/kWp)+3,879,0430.0412Proceed — NPV remains strongly positive.
High CAPEX (870k EUR)+4,321,1510.0415Proceed — NPV robust to +12% CAPEX overshoot.
Low grid price (0.14 EUR/kWh)+3,272,1630.0373Proceed — even at compressed industrial tariff, NPV is positive.
Low escalation (1.5%/yr)+3,717,0030.0373Proceed — slow tariff growth still produces positive NPV.
High discount rate (6.5%)+4,067,0830.0388Proceed — robust to higher WACC.
Low self-consumption (55%)+3,770,5970.0373Proceed — even at low self-consumption, NPV is positive.
High degradation (0.65%/yr)+4,400,5230.0377Proceed — degradation assumptions are a minor driver.

7. Standards & certification (generic parametric reference)

This page is a generic parametric reference. No specific test certificate number is asserted because no specific module, inverter, or mounting kit has been selected. The certifications below are the normative references for the equipment families named in §1; certificate numbers and issuing body IDs (TÜV Rheinland / TÜV SÜD / VDE / DNV) are populated against the shipped OEM datasheet at RFQ time.

StandardTitle (as published)Applies toCatalogue / publication URL
IEC 61215-1:2021 / IEC 61215-2:2021Crystalline silicon PV modules — Design qualificationModules (generic)IEC Webstore — catalogue (full designation in text)
IEC 61730-1:2016 / IEC 61730-2:2016PV module safety qualificationModules (generic)IEC Webstore — catalogue (full designation in text)
UL 61730-1Photovoltaic (PV) Module Safety Qualification — Part 1Modules (US market, optional)shopulstandards.com UL 61730-1
IEC 62109-1:2010 / IEC 62109-2:2011Safety of power converters for use in photovoltaic power systemsInverters (generic)IEC Webstore — catalogue (full designation in text)
EN 50549-1:2019 / EN 50549-2:2019Requirements for generating plants to be connected in parallel with distribution networksGrid interconnection (EU)Member-State national regulator publication (full designation in text)
CE markingEU conformity (LVD 2014/35/EU, EMC 2014/30/EU, RED 2014/53/EU where applicable)All electrical equipment placed on the EU marketEU OJ — full directive designations in text

8. Customs / duty lookup (HS code block — rates PENDING)

All duty rates below are marked PENDING. The lookup must be executed against the official EU TARIC database before any shipment. TradVolt does not assert any duty rate as fact.

ComponentCN / HS codeEU customs dutyLookup path
Crystalline silicon PV modules8541.43PENDINGTARIC consultation — enter 8541.43 + origin country
Solar cells8541.40PENDINGTARIC consultation — enter 8541.40 + origin country
Inverters, static converters8504.40PENDINGTARIC consultation — enter 8504.40 + origin country
Mounting structures, aluminium7610.90PENDINGTARIC consultation — enter 7610.90 + origin country
DC cables, PV-rated8544.49PENDINGTARIC consultation — enter 8544.49 + origin country

Lookup instructions

  1. Open the European Commission's TARIC consultation page.
  2. Enter the CN code (e.g., 8541.43) and the country of origin.
  3. Capture the MFN duty, any anti-dumping measure, and any suspension note.
  4. Confirm with the destination Member State's national customs authority.
  5. Save the TARIC screenshot with the consultation date for the customs broker.

For non-EU destinations: USITC HTS search, UK Global Tariff, Japan Customs, Australian Border Force, South African Revenue Service, Ghana Revenue Authority, Uganda Revenue Authority. Sea/air terms of trade: ICC Incoterms 2020. IATA cargo rules: IATA Dangerous Goods (DGR). Wood packaging: IPPC ISPM 15. For lithium batteries in any add-on storage: UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7 (UN 38.3); see also Regulation (EU) 2023/1542.

9. Call to action

Request a formal quotation referencing this r9 reference document. Your RFQ will be answered with equipment-specific data (module family and wattage, inverter family, mounting kit, OEM manual revisions, and TÜV/VDE certificate IDs) against the inputs in §2.

Request a formal RFQ