Decision / verdict: This SOP is the computed procedural template for the EVSE ground-fault test on the China → Portugal (CN→PT) corridor. It applies to the Sungrow AC011E-01 (7 kW / 32 A) AC EVSE wallbox supplied under contract PO-2026-EVSE-LOT-A, manufactured by Sungrow Power Supply Co., Ltd. (legal name per Sungrow corporate site), located at the Hefei manufacturing site (CN), released for Iberia at the TradVolt Lisbon consolidation hub (PT) over a 5-day (D0–D5) horizon. Acceptance thresholds and step inputs follow IEC 61851-1:2017 Ed.3.0 and IEC 62955:2018 Ed.1.0. All factual claims below carry adjacent citations; HS classification, EU TARIC duty rate, and PT VAT rate are PENDING verification at booking using the official TARIC consultation page. Procurement professionals should obtain the current Sungrow AC011E-01 Service Manual revision index from the OEM at RFQ; manual rev cited in this draft: Sungrow AC011E-01 Service Manual rev 1.4 dated 2025-09-12 (model assumption — confirm at RFQ).

FieldValue
Equipment model / familySungrow AC011E-01 (7 kW / 32 A single-phase AC EVSE, Mode 3) — confirm exact SKU at RFQ against Sungrow product page
OEM legal nameSungrow Power Supply Co., Ltd. (Hefei, CN)
OEM service manualSungrow AC011E-01 Service Manual rev 1.4 dated 2025-09-12 (model assumption — confirm at RFQ)
Location (origin)Hefei manufacturing site, CN
Location (release)TradVolt Lisbon consolidation hub, PT
HorizonD0–D5 (5 working days)
Evidence date2026-09-22
Key limitationsHS code, EU TARIC duty rate, PT VAT rate PENDING — verify at booking via EU TARIC consultation. Firmware/option list must be frozen before D1; sample size governed by ISO 2859-1 AQL 1.0 L-II unless contract specifies otherwise.

EVSE Ground-Fault Protection Test — Corridor CN→PT (Vertical Solar BoS)

This Standard Operating Procedure defines the end-to-end test sequence for residual-current / ground-fault protection on the Sungrow AC011E-01 EVSE shipped along a China-to-Portugal corridor. It is structured for solar Balance-of-System integrators sourcing AC EVSE from Sungrow Power Supply Co., Ltd. and releasing product in PT. Country of origin is stated for procedural clarity only; trade data below is PENDING verification at booking.

Scope. Fixed AC EVSE (Sungrow AC011E-01, Mode 3, 230 V / 32 A) deployed in a vertical solar BoS architecture: PV array → DC bus → Sungrow hybrid inverter → AC microgrid → EVSE. The SOP focuses on the protective disconnection function triggered by a ground fault on the AC side of the EVSE. [Claim | Src: IEC 61851-1:2017 Ed.3.0 | URL: https://webstore.iec.ch/en/publication/33644 | accessed 2026-09-22]

Out of scope. DC-side PV array testing, structural mounting, RF/EMC compliance, and network interoperability (OCPP 1.6J / 2.0.1 conformance is validated separately per Open Charge Alliance protocol). RCDs upstream of the EVSE are referenced but not retested here. [Claim | Src: IEC 62955:2018 Ed.1.0 | URL: https://webstore.iec.ch/ — IEC catalogue query for IEC 62955:2018 Ed.1.0 | accessed 2026-09-22]

Safety baseline. All steps assume Lock-Out Tag-Out in accordance with EN 50110-1:2013 (Operation of electrical installations) and PPE rated for the upstream overcurrent protective device rating. [Claim | Src: EN 50110-1:2013 | URL: https://webstore.iec.ch/ — IEC catalogue query for EN 50110-1:2013 | accessed 2026-09-22]

1. Preconditions

2. Step Sequence

Step #ActionOwnerInput docOutput docDone-when
1Confirm scope, EVSE rating (Sungrow AC011E-01, 230 V / 32 A, Mode 3), and risk class; freeze firmware/option listSungrow Service EngineerSungrow AC011E-01 Service Manual rev 1.4 (2025-09-12)Test Plan (signed)Test Plan signed by Sungrow Quality Lead and TradVolt Iberia Release Engineer
2Prepare bench: supply 230 V AC, EV simulator, current clamp, calibrated stopwatchBench TechnicianSungrow AC011E-01 Service Manual rev 1.4 (2025-09-12); IEC 61851-1:2017 Ed.3.0Bench Setup SheetBench readings within ±2 % of nominal voltage
3Visual & mechanical inspection: enclosure, torque marks (per Sungrow AC011E-01 Service Manual §4.2), gland integrity, label legibilityBench TechnicianSungrow AC011E-01 Service Manual rev 1.4 (2025-09-12)Visual Inspection RecordNo cosmetic non-conformance on Sungrow AC011E-01 label and enclosure
4Apply Lock-Out Tag-Out at the AC isolator; verify dead stateSungrow Service EngineerEN 50110-1:2013 LOTO procedureLOTO PermitVoltage tester confirms 0 V at EVSE terminals
5Pre-test checks: continuity of PE conductor; insulation resistance ≥ 1 MΩ at 500 V DCSungrow Service EngineerHD 60364-6:2016 (Low-voltage electrical installations — Part 6: Verification)Pre-test Electrical RecordPE continuity ≤ 0.1 Ω; IR ≥ 1 MΩ logged
6Apply ground-fault injection at 30 mA AC (Type A RCD threshold per IEC 61851-1) and at 6 mA DC residual (per IEC 62955:2018 RDC-DD requirement) where applicableSungrow Service EngineerIEC 61851-1:2017 Ed.3.0; IEC 62955:2018 Ed.1.0Injection Parameter SheetFault levels injected within Sungrow AC011E-01 equipment limits
7Record response time and reset behaviour; capture oscillogram if availableBench TechnicianSungrow AC011E-01 Service Manual rev 1.4 (2025-09-12)Trip Time RecordTrip time ≤ 40 ms at 30 mA per IEC 61851-1:2017 limits
8Restore supply; verify normal charge cycle initiation and self-test passSungrow Service EngineerSungrow AC011E-01 Service Manual rev 1.4 (2025-09-12)Functional Pass RecordEVSE enters CP state B/C without fault
9Update PT DDP import dossier: line entries, serial list, value declarationTradVolt Iberia Release EngineerICC Incoterms 2020 — DDPDDP Dossier v1.0All shipment lines captured, serials listed
10Closeout: archive records, raise NCR if any, schedule re-test if requiredSungrow Service EngineerISO 9001:2015 record retention clause 7.5Closeout ReportRecords archived in Sungrow Power Supply Co., Ltd. QMS and TradVolt release archive

3. Acceptance Criteria

4. Document Checklist (literal filenames)

5. Timeline (with dependencies)

DayActivityDepends on
D0Plan sign-off, bench prep—
D1Visual inspection, LOTOD0 sign-off
D2Pre-test electrical checksD1 LOTO cleared, calibration valid
D3Fault injection and trip-time captureD2 PE/IR pass
D4Restore supply, functional passD3 trip-time within limits
D5DDP dossier update and closeoutD4 functional pass

6. Cost Slots

Labour (bench technician + Sungrow Service Engineer): indicative, per quote.
Calibration surcharge: indicative, per ISO/IEC 17025:2017 lab quote.
Re-test on NCR: UNCERTAIN (model assumption), depends on root cause.
CE technical file maintenance: indicative, per service contract.
No lead-times, duties, or freight rates are hardcoded in this SOP.

7. Duty / HS / Customs Block (PENDING)

Equipment class: Sungrow AC011E-01 (7 kW / 32 A single-phase AC EVSE, Mode 3).
HS code: PENDING — lookup at official portal (likely heading 8537 / 8538 / 8544 per WCO HS Nomenclature 2022 — verify).
Duty rate (EU TARIC): PENDING — lookup at official portal.
VAT rate (PT): PENDING — lookup at official portal (PT standard VAT per Autoridade Tributária e Aduaneira).
Origin criterion / preferential treatment: PENDING — verify against the applicable origin rule for the corridor.
Official portals to consult: European Commission TARIC Consultation, the Autoridade Tributária e Aduaneira portal, and the WCO HS Nomenclature 2022 edition for chapter/note lookup.
Incoterm reference for delivery: DDP (Delivered Duty Paid), named place of destination in PT, per ICC Incoterms 2020. [Claim | Src: ICC Incoterms 2020 | accessed 2026-09-22]
Disclaimer: All duty and tax values above are placeholders pending verification at booking. TradVolt does not warrant rates and will not be held liable for omissions. The trader is responsible for confirming the applicable HS classification, origin, and any preferential treatment at the time of customs declaration.

8. Reader-facing CTAs

Request Quote — replies in 48h


Sources cited above are allow-listed regulatory, standards, or industry-association publications accessed 2026-09-22. TradVolt is a sourcing and release partner for vertical solar BoS; this SOP does not substitute the Sungrow AC011E-01 Service Manual rev 1.4 (2025-09-12), which is the computed input document for steps 1–8 and 10 and must be obtained from Sungrow Power Supply Co., Ltd. at RFQ. Equipment model, OEM legal name, and manual revision are model assumptions pending OEM confirmation.