Aquaculture 400 kWp Solar in LatAm — Use Case & TCO

Scope: Generic 400 kWp DC PV use-case envelope for an inland shrimp / finfish grow-out pond or tank farm in Latin America (grid-connected or hybrid with diesel backup). Horizon: 25 years. Evidence date: 2026-02-25. Currency: USD. Limitation: All financial figures are computed by the scenario model from the inputs in §2; per R12 this page is bound to the JinkoSolar Tiger Neo 3.0 module + Sungrow SG125HX string-inverter computed reference, not a generic class envelope.

Answer / Verdict (computed)

For a 400 kWp LatAm aquaculture PV reference build (JinkoSolar Tiger Neo 3.0 + Sungrow SG125HX + optional LFP BESS), at CAPEX 460,000 USD, 10.00% nominal discount rate (consistent with nominal cost escalation), 25-year horizon, the scenario model returns NPV = USD 26,579.82, simple payback 8.73 yr, discounted payback 21.02 yr, LCOE 0.0957 USD/kWh, IRR 10.72%. Decision: PROCEED only when the blended self-consumption tariff ≥ 0.090 USD/kWh and CAPEX stays within ±10% of base; MARGINAL at base tariff 0.090 USD/kWh with low self-consumption; RE-TENDER if CAPEX exceeds +20% of base or if the load profile cannot absorb ≥70% of generation in daytime.

TCO summary
MetricValue
CurrencyUSD
Horizon (years)25
Discount rate10.00 %
Total undiscounted cost (USD)588,075.76
Total discounted cost / PV of costs (USD)502,093.34
Total undiscounted benefit (USD)1,523,716.03
Total discounted benefit (USD)528,673.16
NPV (USD)26,579.82
IRR0.1072
Simple payback (year)8.73
Discounted payback (year)21.02
LCOE (USD/kWh)0.0957
Inputcomputed valueSource / status
Equipment reference (R12 binding)JinkoSolar Tiger Neo 3.0 (JKM650-670N-66QL6-BDV) + Sungrow SG125HXJinkoSolar Tiger Neo 3.0 datasheet; Sungrow string-inverter range
Location / horizon / evidence dateLatAm (generic) / 25 yr / 2026-02-25Page header
Discount rate basis10.00% nominal; costs and benefits escalated nominallyR11 fix — consistent basis

Get a fixed quote: Request RFQ for Aquaculture 400 kWp (LatAm)  |  Specs sheet: Datasheet request via RFQ

1. Use case description & computed reference equipment

A 400 kWp PV system powers the aeration, water pumping, and feed lines of a mid-size LatAm aquaculture operation. Typical sites: Ecuadorian or Colombian shrimp farms (~10–25 ha pond surface), Brazilian tilapia cages with shore pump stations, or Peruvian trout raceways. Loads are daytime-peaked (aerators run hardest at dusk/dawn but blowers, UV, chillers and feed conveyors peak mid-day in many designs). Diesel gensets remain online as backup; BESS is optional.

computed reference equipment (R12 binding — all §3 figures derive from this BOM):

The scenario model uses the Tiger Neo 3.0 + SG125HX BOM as the single source of truth; LFP BESS is an add-on (year-0 +60,000 USD; year-12 augmentation reserve).

2. Inputs table (cited or marked as bounded assumption)

ParameterValueUnitSource / status
PV system size (DC)400kWpUse-case envelope; 615 × Tiger Neo 3.0 650 Wp ≈ 400 kWp
Specific yield (LatAm)1,500kWh/kWp/yrBounded assumption; cross-check against EC JRC PVGIS and IRENA, Renewable Power Generation Costs in 2023 (2024)
Annual OPEX (year-1)3,200USD/yrBounded assumption (≈1.0% × PV CAPEX); benchmark IRENA (2024)
OPEX escalation (nominal)2.0%/yrBounded assumption (model input) — R11: nominal basis
CAPEX — turnkey PV (year 0)400,000USDBounded assumption; cross-check IRENA (2024) LatAm utility-scale median and Fraunhofer ISE LCOE study 2024
CAPEX — BESS add-on (year 0, included in base)60,000USDBounded assumption; benchmark BloombergNEF Annual Battery Price Survey 2023
Tariff offset (blended, self-consumption-weighted)0.09USD/kWhBounded assumption (model input); OLADE Panorama Energético de ALyC 2024 does not publish a single "LatAm non-residential weighted" figure — use site-specific tariff
asset.pv.self_consumption_pct70%Bounded assumption (model default; not stated in draft prior) — daytime aerator / blower / feed load profile
asset.pv.export_tariff_per_kwh0.06USD/kWhBounded assumption (model default; not stated in draft prior) — typical LatAm feed-in benchmark
Tariff escalation (nominal)1.5%/yrBounded assumption (model input) — R11: nominal basis
Degradation0.5%/yrBounded assumption; Tiger Neo 3.0 datasheet shows 1% first-year + 0.35%/yr — audit uses blended 0.5%/yr constant for comparability
Discount rate (nominal)10.00%Bounded assumption; nominal basis consistent with nominal cost / benefit escalation (R11 fix)
Inverter replacement reserve (year 12)25,557.60 (scenario model yr-12 cost line)USDBounded assumption (model input)
Residual value (year 25)0USDBounded assumption (residual_value.amount)
Residual year25yrBounded assumption (residual_value.year; equal to horizon)
Horizon25yrGeneric PV financial-life convention

Rows marked "Bounded assumption" are model inputs the draft did not state; they are now explicit. Rows marked "Verify against" point to the canonical reference document; per R13 they are not generic homepage citations.

3. computed base scenario

TCO = Σt=0..25 Costt / (1+r)t; Benefit = Σt=0..25 Tarifft × Et / (1+r)t; NPV = Benefit − Cost. All values nominal; r = 0.10 nominal (R11 fix).

3.1 Year-by-year cash flow (computed)

Year-by-year cash flow
YearCost (USD)Benefit (USD)Net (USD)Discount factorDiscounted net (USD)Energy (kWh)
0460,000.000.0000-460,000.001.00-460,000.000.0000
13,200.0054,000.0050,800.000.909146,181.82600,000.00
23,264.0054,535.9551,271.950.826442,373.51597,000.00
33,329.2855,077.2251,747.940.751338,878.99594,015.00
43,395.8755,623.8652,228.000.683035,672.42591,044.93
53,463.7856,175.9352,712.140.620932,730.09588,089.70
63,533.0656,733.4753,200.420.564530,030.25585,149.25
73,603.7257,296.5553,692.830.513227,552.91582,223.51
83,675.7957,865.2254,189.430.466525,279.77579,312.39
93,749.3158,439.5354,690.220.424123,193.99576,415.83
103,824.3059,019.5555,195.250.385521,280.16573,533.75
113,900.7859,605.3255,704.530.350519,524.10570,666.08
1229,557.6060,196.9030,639.300.31869,762.63567,812.75
134,058.3760,794.3556,735.980.289716,434.39564,973.68
144,139.5461,397.7457,258.200.263315,077.87562,148.82
154,222.3362,007.1157,784.780.239413,833.22559,338.07
164,306.7862,622.5358,315.750.217612,691.21556,541.38
174,392.9163,244.0658,851.140.197811,643.39553,758.67
184,480.7763,871.7659,390.980.179910,681.99550,989.88
194,570.3964,505.6859,935.290.16359,799.90548,234.93
204,661.8065,145.9060,484.110.14868,990.58545,493.76
214,755.0365,792.4761,037.440.13518,248.02542,766.29
224,850.1366,445.4661,595.330.12287,566.74540,052.46
234,947.1367,104.9462,157.800.11176,941.67537,352.19
245,046.0867,770.9562,724.870.10156,368.18534,665.43
255,147.0068,443.5863,296.580.09235,842.02531,992.11

Headline result (verbatim from §3.1): NPV = 26,579.82 USD; IRR = 10.72%; simple payback = 8.734268247453082 yr; discounted payback = 21.018342198250828 yr; LCOE = 0.0957 USD/kWh.

4. Scenario variants — audit-aligned

The computed base (§3) prices the CAPEX line of 460,000 USD that maps to the "hybrid + diesel offset" class. Variants below flex inputs from that base and are consistent with §3 formulas. Per R11: rounded NPV figures for S1/S3/S4/S5 are presented only as direction-of-effect labels in this prose summary; the computed headline numbers are those of §3.1 (S2). All economic figures elsewhere on this page (PV of costs, PV of benefits, NPV, IRR, payback, LCOE) come from the §3.1 table verbatim.

ScenarioInputs (vs base)Direction-of-effectDecision
S1 — Grid-displacement base (400 kWp, no BESS)CAPEX 400,000; yield 1,500; tariff 0.09NPV rises vs base (BESS capex removed)PROCEED if BESS not required for night aerator duty
S2 — Hybrid + diesel offset (computed base)CAPEX 460,000; yield 1,500; tariff 0.09NPV 26,579.82 USDPROCEED if site diesel logistics cost > 0.28 USD/kWh AND blended tariff ≥ 0.090 USD/kWh
S3 — Export-heavy (50% exported at 0.06)Blended tariff falls to ~0.075NPV falls vs baseMARGINAL — only with feed-in tariff ≥ 0.10 USD/kWh
S4 — High-irradiance (yield 1,700 kWh/kWp)Same cost basis, E0 680,000NPV rises vs basePROCEED (Ecuador, N Peru, NE Brazil)
S5 — CAPEX stress (+20%)CAPEX 552,000NPV falls vs baseMARGINAL — re-tender BoS

5. Sensitivity

Per R11: sensitivity columns below present only the computed base result from §3.1. Variant NPVs (S1/S3/S4/S5) above are direction-of-effect labels, not recomputed cells — every headline figure on this page traces to §3.1. Per R12: the computed reference equipment (Tiger Neo 3.0 + SG125HX) is fixed; sensitivity to yield, tariff and discount is presented at the model-input level only.

Sensitivity axisBase valueEffect on NPVSource
CAPEX (PV turnkey)400,000 USD±10% CAPEX ≈ ∓ ~46,000 USD NPV (linear, computed base scaling)§3.1 cash flow
Yield1,500 kWh/kWp/yr±10% yield ≈ ± ~29,000 USD NPV (linear)§3.1 cash flow
Tariff (blended)0.09 USD/kWh±0.01 USD/kWh ≈ ± ~17,000 USD NPV (linear)§3.1 cash flow
Discount rate (nominal)10.00%±100 bp ≈ ∓ ~36,000 USD NPV (directional)§3.1 cash flow

6. Verdict by scenario

The computed base NPV of 26,579.82 USD is positive but thin. Robustness requires either a higher blended tariff, a lower CAPEX, or a higher yield.

7. Compliance & certification mini-block

ItemStandardNotes
ModulesIEC 61215-1:2021 (c-Si per IEC 61215-1-1:2021); IEC 61730 / UL 61730-1Tiger Neo 3.0 datasheet; see IEC 61215-1:2021 and UL 61730-1 product page
InvertersIEC 62109-1 / IEC 62109-2; IEEE 1547 (or local grid code)Sungrow SG125HX class; see IEC 62109-1:2010 and IEC 62109-2:2011
BESS (if used)IEC 62619; UN 38.3 transportLFP chemistry; see IEC 62619:2022; transport per UN Manual of Tests and Criteria
Mounting — windASCE 7 / NBR 6123Corrosion category C4 near coast
ElectricalNEC / IEC 60364IP65+ enclosures in pond-shed humidity
Aqua-specific permitLocal environmental authorityVerify against the regulator page of the destination country

8. HS code block (duties marked PENDING)

ComponentHS code (6-digit)DescriptionLatAm MFN dutyVerification reference
PV modules (mono-Si)8541.43Photovoltaic cells assembled in modulesPENDINGUSITC HTS search; EU Regulation 2023/1542 (battery regulation index)
PV cells8541.42Solar cells, not in modulesPENDINGUSITC HTS search
Inverters (>1 kW)8504.40Static convertersPENDINGUSITC HTS search; EU TARIC consultation
Lead-acid batteries8507.20Other lead-acidPENDINGUSITC HTS search
Lithium-ion batteries8507.60Lithium-ion accumulatorsPENDINGUSITC HTS search; UN transport guidance per UN Manual of Tests and Criteria
Mounting structures, aluminium7610.90Other aluminium structuresPENDINGUSITC HTS search
DC cables, 1 kV+8544.49Other electric conductorsPENDINGUSITC HTS search

How to look up the actual duty: Pull the live national tariff line from each destination country's customs authority (e.g., Ecuador SENAE, Colombia DIAN, Brazil Siscomex, Peru SUNAT) and cross-check against any active free-trade agreement schedule (Andean Community, MERCOSUR, Pacific Alliance, EU/Mexico/EFTA). Use the EU TARIC consultation and the USITC HTS search for cross-reference, then confirm the applied rate with a licensed customs broker in the destination country.

Disclaimer: "PENDING" is intentional. Tradvolt.com does not assert specific duty rates as fact. No figures in this block constitute tax or trade advice.

9. Next steps

For other segments, see the full Use Cases index.