Verdict — invest. A 50 kW grid-tied PV installation on a south-central Vietnam hangar, anchored on a Sungrow SG50CX-P2-CN string inverter and Jinko Solar JKM620N-78HL4-BDV modules, returns NPV = USD 13,949.24 at an 8.00 % discount rate over a 25-year horizon, with simple payback 8.67 yr, discounted payback 14.73 yr, IRR 11.22 % and LCOE USD 0.0696 /kWh. Equipment: Sungrow SG50CX-P2-CN inverter (50 kW AC, 3-phase 400 V, 50 Hz). Location: south-central Vietnam hangar rooftop. Horizon: 25 yr. Evidence date: 2026-09-21. Limitation: yields are NASA POWER / PVGIS-class long-term averages, self-consumption share and EVN tariff are bounded model assumptions; duty/VAT are PENDING GDVC lookup — not a quote.

Decision snapshot — 50 kW on-grid, hangar rooftop, VN
MetricValueNote
Equipment (BoS anchor)Sungrow SG50CX-P2-CN, 50 kW, 3-ph 400 VOEM datasheet cited below
ModulesJinko Solar JKM620N-78HL4-BDV (≈620 Wp mono)OEM datasheet cited below
LocationSouth-central Vietnam (≈12 °N)PVGIS / NASA POWER class
Horizon25 yearsModel horizon
Discount rate8.00 %Bounded model assumption
NPVUSD 13,949.24PV(benefit) − PV(cost)
IRR11.22 %Project IRR
Simple payback8.67 yrUndiscounted
Discounted payback14.73 yrAt 8.00 %
LCOEUSD 0.0696 /kWhPV(cost) ÷ PV(generation)
DecisionProceedSubject to RFQ + GDVC duty confirmation

Import a Sungrow SG50CX-P2-CN On-Grid Inverter from China to Vietnam — Hangar-Rooftop TCO & Landed Cost

A B2B reference page for solar EPCs and industrial-rooftop owners sizing a 50 kW grid-tied PV installation on a hangar in Vietnam. It structures CapEx, OpEx, payback and sensitivity around the Sungrow SG50CX-P2-CN string inverter as the BoS anchor, with an explicit duty-stack block against the Vietnam Customs (GDVC) tariff.

Use-caseHangar rooftop 50 kW
InverterSungrow SG50CX-P2-CN
OriginChina (CN)
DestinationVietnam (VN)
As-of2026-09-21
Request Quote — replies in 48h OEM datasheet pack (PDF)

1. Use case — Hangar rooftop, 50 kW on-grid

A typical industrial hangar in Vietnam presents a low-slope metal deck with limited shading and high load-bearing capacity. A 50 kW grid-tied PV system fits as a self-consumption + surplus-export asset behind a single three-phase 400 V AC connection point, feeding a warehouse or small-assembly load during daylight. The inverter is the BoS anchor: its AC output, MPPT range, ingress protection and grid-compliance evidence drive the rest of the procurement logic.

Equipment selection — exact models

FunctionModelOEMPublic datasheet / product page
On-grid string inverter (BoS anchor)Sungrow SG50CX-P2-CNSungrow Power Supply Co., Ltd.SG50CX-P2-CN Datasheet (PDF); product index Sungrow string inverter range
PV modules (~620 Wp mono)Jinko Solar JKM620N-78HL4-BDV (Tiger Neo)Jinko Solar Co., Ltd.JKM620N-78HL4-BDV Datasheet (PDF)
Mounting structure (metal-roof, non-penetrative)K2 Systems S-Dome 6.10 (clamped rail, trapezoidal sheet)K2 Systems GmbHK2 Systems (mounting)
Yield source (irradiation, south-central VN)NASA POWER — Prediction of Worldwide Energy Resource (POWER) project, hourly/meteorology surfaceNASA Langley Research CenterNASA POWER project; PVGIS cross-check PVGIS (JRC)
EVN reference (grid, tariff framework)Vietnam Electricity (EVN) — group portalEVNEVN corporate portal

Inverter limits (torque / SOC / voltages) must be read against the Sungrow SG50CX-P2-CN datasheet revision linked above; module limits against the JKM620N-78HL4-BDV revision linked above. No third-party logos or "No.1" claims are reproduced on this page.

Site & load assumptions (inputs)

ParameterValueUnitSource / evidence
DC system size (modules)~62.5kWpModel assumption — DC/AC ratio 1.25 against 50 kW AC (Sungrow SG50CX-P2-CN rated AC output)
Inverter AC output50kWSungrow SG50CX-P2-CN datasheet — rated AC output 50 kW
Grid interface3-phase, 400 V, 50 Hz—Sungrow SG50CX-P2-CN datasheet — grid interface
Annual specific yield (PLAN)~1,350kWh/kWp/yrModel assumption — south-central VN long-term average; cross-check vs. NASA POWER and PVGIS (JRC)
Annual generation84,375 (Year-1)kWh/yrComputed = 62.5 × 1,350 (Year-1); degrades 0.5 %/yr
Self-consumption share70%Model assumption — daytime warehouse load

Numbers labelled ILLUSTRATIVE — NOT A QUOTE.

2. CapEx — inverter-anchored landed cost

CapEx is built around the inverter (BoS anchor) plus modules, mounting, DC/AC cabling, protection, freight/logistics from China to Vietnam, and import duty + VAT (duty/VAT cell is PENDING until the GDVC lookup is recorded against the accessed date).

Line itemQtyUnitUnit price (USD)Subtotal (USD)Source / evidence
Sungrow SG50CX-P2-CN inverter (BoS anchor)1pcsRFQRFQSG50CX-P2-CN datasheet (PDF)
Jinko JKM620N-78HL4-BDV modules (~620 Wp)~101pcsRFQRFQJKM620N-78HL4-BDV datasheet (PDF)
K2 Systems S-Dome 6.10 mounting (metal-roof, non-penetrative)1lotRFQRFQK2 Systems mounting
DC cabling, MC4 connectors, AC cabling1lotRFQRFQIEC 62930 Ed.1
DC/AC protection (SPD Type II, MCB, RCD, isolators)1lotRFQRFQIEC 61643-11 Ed.1
Smart / export meter1pcsRFQRFQUtility-approved meter per local EVN/PC
EPC install + commissioning (labour)1lotRFQRFQEPC scope
Ocean freight CN → VN (FOB or CIF)1lotRFQRFQIncoterms 2020 (ICC)
Marine insurance (~0.3 % CIF)1lotRFQRFQInsurer quote
Import duties + VAT (Vietnam)1lotPENDING — GDVC lookupPENDING — GDVC lookupVietnam Customs (GDVC), tariff search customs.gov.vn — Tariff enquiry, accessed 2026-09-21
Customs broker + port handling (THC)1lotRFQRFQBroker quote

All unit prices RFQ. The duty / VAT row must be replaced with the figure returned by the official Vietnam Customs (GDVC) tariff lookup; see §7.

3. OpEx — 25-year operating view

OpEx is dominated by routine O&M, insurance, a small spare-parts reserve, and an inverter replacement reserve. Modules and mounting are assumed maintenance-light. Numbers below are bounded model assumptions for the TCO run; final OpEx must be re-quoted against the EPC scope.

Line itemYear-1 (USD/yr)Source / evidence
Routine O&M (cleaning, inspection, monitoring)1,200 (escalates 2 %/yr)Model assumption (bounded) — EPC scope
Insurance (~0.2 % of CapEx/yr)included in OpEx scheduleModel assumption (bounded) — insurer quote
Spare parts / unplanned service reserveincluded in OpEx scheduleModel assumption (bounded) — EPC scope
Inverter replacement reservenot provisioned in cashflowModel assumption (bounded) — see TCO summary inputs note

Annual figures are bounded model assumptions for the TCO run; re-validate against EPC scope before procurement.

4. TCO summary — computed

TCO summary
MetricValue
CurrencyUSD
Horizon (years)25
Discount rate8.00 %
Total undiscounted cost (USD)83,436.36
Total discounted cost / PV of costs (USD)60,208.84
Total undiscounted benefit (USD)183,796.59
Total discounted benefit (USD)74,158.08
NPV (USD)13,949.24
IRR0.1122
Simple payback (year)8.67
Discounted payback (year)14.73
LCOE (USD/kWh)0.0696

Year-by-year cash flow

Year-by-year cash flow
YearCost (USD)Benefit (USD)Net (USD)Discount factorDiscounted net (USD)Energy (kWh)
045,000.000.0000-45,000.001.00-45,000.000.0000
11,200.006,121.414,921.410.92594,556.8684,375.00
21,224.006,212.624,988.620.85734,276.9383,953.12
31,248.486,305.185,056.700.79384,014.1783,533.36
41,273.456,399.135,125.680.73503,767.5383,115.69
51,298.926,494.485,195.560.68063,536.0182,700.11
61,324.906,591.255,266.350.63023,318.6982,286.61
71,351.396,689.455,338.060.58353,114.7181,875.18
81,378.426,789.135,410.700.54032,923.2481,465.80
91,405.996,890.295,484.290.50022,743.5181,058.48
101,434.116,992.955,558.840.46322,574.8280,653.18
111,462.797,097.155,634.350.42892,416.4880,249.92
121,492.057,202.895,710.840.39712,267.8579,848.67
131,521.897,310.225,788.330.36772,128.3679,449.42
141,552.337,419.145,866.810.34051,997.4279,052.18
151,583.377,529.685,946.310.31521,874.5278,656.92
161,615.047,641.886,026.830.29191,759.1878,263.63
171,647.347,755.746,108.400.27031,650.9177,872.31
181,680.297,871.306,191.010.25021,549.2977,482.95
191,713.907,988.586,274.690.23171,453.9277,095.54
201,748.178,107.616,359.440.21451,364.4176,710.06
211,783.148,228.426,445.280.19871,280.3976,326.51
221,818.808,351.026,532.220.18391,201.5475,944.88
231,855.188,475.456,620.270.17031,127.5375,565.15
241,892.288,601.736,709.450.15771,058.0875,187.33
251,930.128,729.906,799.780.1460992.8974,811.39

5. Payback & sensitivity

Figures below are labelled ILLUSTRATIVE — NOT A QUOTE. They use the placeholder CapEx and OpEx schedule that produces the TCO summary above (NPV USD 13,949.24, simple payback 8.67 yr, discounted payback 14.73 yr). Self-consumption tariff, export tariff, OpEx escalation, module degradation and residual value are bounded model assumptions.

Bounded model inputs

All-in CapEx (incl. freight + duty placeholder)USD 45,000Model assumption (bounded) — Year-0 spend
Year-1 OpExUSD 1,200Model assumption (bounded) — escalates 2 %/yr
Year-1 generation84,375 kWh62.5 kWp × 1,350 kWh/kWp; degrades 0.5 %/yr
Self-consumption share70 %Model assumption (bounded)
Self-consumed electricity tariff (Year 1, blended)USD 0.0725 /kWh (model blended tariff equivalent)Bounded model assumption; cross-check vs. EVN corporate portal
Export tariff (surplus, Year 1)USD 0.0435 /kWhBounded model assumption; cross-check vs. EVN corporate portal
Tariff escalation2.0 %/yrModel assumption (bounded)
Module degradation0.5 %/yrModel assumption (bounded)
Residual valueUSD 0 (year N/A)Model assumption (bounded) — year/end not specified
Inverter replacement reserveDROPPED — not provisioned in cashflowModel assumption (bounded) — explicit drop note

Bounded model inputs are explicit model assumptions, not sourced facts; they must be re-validated for the specific hangar-rooftop site and the specific OEM model selected via the RFQ.

Sensitivity (simple payback, years)

Recomputed against the bounded inputs (Year-1 generation 84,375 kWh, self-consumption share 70 %, blended tariff 0.0725 USD/kWh, export tariff 0.0435 USD/kWh, Year-1 OpEx 1,200 USD). Tariff column = blended self-consumption tariff in USD/kWh.

All-in CapEx \ Self-consumption tariffUSD 0.0600/kWhUSD 0.0725/kWhUSD 0.0850/kWh
USD 38,0008.817.436.40
USD 45,00010.308.677.46
USD 52,00011.789.918.52

Sensitivity holds generation (84,375 kWh/yr), self-consumption share (70 %), export tariff (0.0435 USD/kWh) and OpEx (1,200 USD/yr, 2 %/yr escalation) constant; only CapEx and self-consumption tariff move. ILLUSTRATIVE — NOT A QUOTE.

6. Compliance & certifications

Standard / markScopeAcceptable issuers (allow-list)Public reference
IEC 62109-1 / -2Power converter safetyTÜV Rheinland, TÜV SÜD, VDE, UL LLC, CSA GroupIEC 62109-1:2010 (TC 82); IEC 62109-2:2011 (TC 82)
IEC 61727 / IEC 62116Grid compliance (anti-islanding, harmonic, FRT)TÜV Rheinland, TÜV SÜD, DNVIEC 61727 Ed.2; IEC 62116 Ed.2
CE markingEU Declaration of Conformity issued by OEMOEM-issued DoC, notified body report referencedEU Regulation (EU) 2019/1020, EUR-Lex CE / market surveillance
IP rating (≥ IP65 outdoor)Ingress protectionIEC 60529 test report from accredited labIEC 60529 Ed.2.2
Vietnam grid acceptanceLocal utility type-test / connection agreementRegional power company (EVN / PC)EVN corporate portal
UN transport (battery / dangerous goods if any storage)UN Manual of Tests and Criteria for lithium cells (UN 38.3)UN publicationUN Manual of Tests and Criteria (UNECE)

No logo, certificate number or "No.1" claim is reproduced on this page. All certificate numbers and issuer names must be verified from the OEM certificate PDF before procurement.

7. Duty / HS stack — Vietnam import

Duty-stack block header
HS national line | Program | As-of: 2026-09-21 | SoT: PENDING
Mark every duty/VAT rate PENDING — lookup. Official portal: Vietnam Customs — General Department of Vietnam Customs (GDVC), tariff enquiry: https://www.customs.gov.vn/index.jsp?pageId=8. Exact HS national line: PENDING — lookup (likely candidate: 8504.40.90 — static converters, heading 8504, chapter 85; final line to be confirmed via the GDVC tariff search).
ComponentRateNotes / SoT
Import duty (MFN) — inverterPENDING — lookupSoT: Vietnam Customs (GDVC) tariff enquiry, https://www.customs.gov.vn/index.jsp?pageId=8, accessed 2026-09-21; candidate heading 8504
Import duty (preferential) — ASEAN / EVFTA / RCEPPENDING — lookupSoT: GDVC preferential tariff schedule, accessed 2026-09-21; C/O eligibility PENDING — lookup. EVFTA text reference: EU-Vietnam FTA (EUR-Lex)
VATPENDING — lookupSoT: GDVC tariff page + General Department of Taxation, accessed 2026-09-21
Special consumption tax (SCT)PENDING — lookupSoT: GDVC, accessed 2026-09-21; inverters typically not in SCT scope but verify per HS line
Other (environmental, recycling fee)PENDING — lookupSoT: GDVC, accessed 2026-09-21

No rate is hardcoded. Final landed duty + VAT cell in the CapEx table must be replaced with the figure returned by the official GDVC lookup, with the accessed date recorded.

8. Request a quote

Submit the form below. Tradvolt replies within 48 hours with OEM availability for the Sungrow SG50CX-P2-CN, a firm FOB / CIF price, lead time, and the certificate pack (IEC 62109 / IEC 61727 / IEC 62116, CE DoC, IP test report).

Request Quote — replies in 48h OEM datasheet pack (PDF)

9. Frequently asked questions

What HS code applies to a Sungrow SG50CX-P2-CN imported into Vietnam?

Candidate national line 8504.40.90 (static converters) under heading 8504, chapter 85, per Vietnam Customs (GDVC) tariff nomenclature. The exact national line, MFN rate and any EVFTA / RCEP preferential rate must be confirmed at the live GDVC tariff enquiry page (https://www.customs.gov.vn/index.jsp?pageId=8) before procurement.

Do Vietnamese projects require EVN grid-interconnection approval?

Yes. Rooftop grid-tied systems require a grid connection agreement with the regional power company (EVN / regional PC). Final scope of approval is confirmed with the buyer's local utility; the public framework is set out by EVN (https://www.evn.com.vn/).

Which certifications should be requested for a Sungrow SG50CX-P2-CN used in Vietnam?

Commonly accepted evidence: IEC 62109-1/-2 (safety, IEC 62109-1 / IEC 62109-2), IEC 61727 / IEC 62116 (grid compliance, anti-islanding), issued by accredited CBs such as TÜV Rheinland or TÜV SÜD, and a CE Declaration of Conformity issued by the OEM. Vietnam-specific utility type-test acceptance is confirmed with the local EVN/PC.

Is the payback shown on this page a quote?

No. The payback, sensitivity, NPV, IRR and LCOE figures are ILLUSTRATIVE — NOT A QUOTE. They depend on the inverter OEM model (Sungrow SG50CX-P2-CN), FOB/CIF price, freight, duty/VAT, irradiation, EVN tariff and financing assumptions that must be re-validated for the specific hangar-rooftop site via the RFQ.

What Incoterm should be used for CN → VN inverter procurement?

Common choices: FOB Shanghai / Ningbo / Shenzhen (buyer arranges ocean freight and insurance) or CIF Hai Phong / Da Nang / Cat Lai (seller arranges freight to named Vietnamese port), per ICC Incoterms 2020. CIF is convenient for a first import; FOB gives the buyer cost control. The selected Incoterm must be entered in the RFQ form.

Can Tradvolt provide a Vietnamese-language datasheet?

The OEM datasheet for the Sungrow SG50CX-P2-CN is provided in English (SG50CX-P2-CN datasheet, PDF). A Vietnamese translation, if required, is typically prepared by the importer for local utility submission and is not included by default.