Tradvolt

Orchard Solar 250 kWp — Use-Case & Total Cost of Ownership (Australia)

Verdict (scenario model, evidence date 2026-09-22): a 250 kWp Australian orchard solar PV system built on Huawei SUN2000-330KTL-H1 string inverters and Jinko Tiger Neo 580 W (N-type) bifacial modules, evaluated over a 25-year horizon at a 5.00 % real discount rate, returns NPV = AUD 1,386,278, simple payback = 2.57 years, discounted payback = 2.82 years, IRR = 39.61 %, and a levelised cost of energy of AUD 0.0648/kWh. The verdict is Go for the base case. Limitation: the figures are computed for the specific equipment family, yield, tariff, and capex assumption stated in §3 and are not transferable to other inverter/module pairs or tariff structures without re-running the scenario model.

Decision summary — base case (computed, do not round)
Equipment / location / horizonHuawei SUN2000-330KTL-H1 + Jinko Tiger Neo 580 W / inland AU orchard (NSW–SA–QLD band) / 25 yr
Discount rate (real)5.00 %
NPVAUD 1,386,278.24
IRR39.61 %
Simple payback2.57 yr
Discounted payback2.82 yr
LCOE (levelised cost, discounted)AUD 0.0648 / kWh
Total undiscounted costAUD 400,699.99
Total discounted cost (PV of costs)AUD 342,844.44
Total undiscounted benefit (avoided grid)AUD 3,159,277.28
Total discounted benefit (PV of avoided grid)AUD 1,729,122.68
Verdict (base case)Go

1. Use-case profile

A mid-sized Australian orchard operator (citrus, stone fruit, or apple) is evaluating a 250 kWp ground-mount array on a non-productive perimeter or fallow paddock. The system displaces daytime irrigation-pump load (typical orchard seasonal pumping coincides with peak sun) and exports the surplus. Site class is regional NSW/SA/Qld inland; tariff assumption is a small-commercial Time-of-Use structure. The operator wants one number: levelised cost of energy in AUD/kWh over 25 years, not a brochure figure.

2. Equipment anchor (named models)

This page fixes a specific, publicly marketed equipment family. The TCO in §4 is computed against this anchor and is not transferable to other inverters or modules without re-running the scenario model.

BlockModel / familyKey limits (OEM)Source
Inverter Huawei SUN2000-330KTL-H1 (330 kW, three-phase, 1,500 V DC, 8 MPPT) Max. DC voltage 1,500 V; max. MPPT current 26 A per MPPT; operating temp −25 °C to +60 °C; IP66 Huawei SUN2000-330KTL-H1 product page — OEM manual title: SUN2000-330KTL-H1 User Manual; manual revision confirmed at RFQ
Modules Jinko Solar Tiger Neo N-type 580 W bifacial (JKM580N-72HL4-BDV or equivalent JKM-N-series at 575–585 W STC) STC Pmax 580 W; Voc ≈ 51.5 V; Isc ≈ 14.0 A; max. system voltage 1,500 V DC; bifaciality 70 ± 5 % JinkoSolar product page — OEM datasheet title: Tiger Neo — JKM-N-series Datasheet; exact model and datasheet revision confirmed at RFQ (Jinko datasheet PDFs are gated by region)
Mounting K2 Systems N-Rack ground-mount system (driven-pile ground mount + S-Rack rail) Wind/snow load classification confirmed per site at RFQ K2 Systems N-Rack ground-mount system product page — manual revision confirmed at RFQ (downloads are bot-walled)

Equipment limits (torque on terminations, SOC windows if a battery is added later, voltage windows, MPPT current) are not asserted on this page — they must be confirmed against the OEM manual revision that ships with the procurement lot, which the Tradvolt RFQ flow records per shipment.

3. Inputs table (named-source)

Every input below is tied to a primary source document URL or, where the source is JS-rendered, to the OEM model designation (confirmed at RFQ). Inputs not derivable from the cited documents are flagged as bounded model assumptions in §6.

#InputValueUnitSource
1Nameplate capacity250kWp (DC-STC)System specification (this page)
2Specific yield (year 1)1,560kWh / kWp / yrModel assumption (bounded); consistent with the inland AU yield band reported in CSIRO GenCost 2023-24, p. 22, Table 4 (utility-scale PV capacity factor / specific yield). Document: GenCost 2023-24: Project technology cost estimates, CSIRO, 2024, p. 22, Table 4 — CSIRO GenCost 2023-24
3Module degradation (linear)0.4% / yrIEC 61215-1:2021 and IEC 61215-2:2021, crystalline-silicon module design qualification and performance convention — catalogue at IEC Webstore; cite designations IEC 61215-1:2021 and IEC 61215-2:2021 verbatim
4System lifetime25yearsAEMO/ARENA financial-asset life convention for utility-scale PV, applied to commercial-scale. Document: 2024 Inputs and Assumptions workbook, AEMO ISP, accessed via AEMO ISP publication hub; the workbook is hosted on the AEMO ISP portal and labelled "PENDING — confirm at RFQ" for the exact sheet/cell
5Inverter replacement (1×)year 12—Model assumption (bounded); consistent with the 10–15 yr string-inverter service-life band reported in AEMO cost benchmarking for utility-scale PV
6Turnkey CAPEX1.10AUD / WpModel assumption (bounded); consistent with the mid-range utility-scale benchmark in CSIRO GenCost 2023-24, Table 4 (AUD-converted). Document: GenCost 2023-24, CSIRO, 2024, Table 4 — CSIRO GenCost 2023-24
7Fixed OPEX (O&M + insurance)1.2% of CAPEX / yrModel assumption (bounded); consistent with the 1.0–1.5 %/yr band reported in AEMO cost benchmarking for utility-scale PV. Document: 2024 ISP Inputs and Assumptions workbook, AEMO — AEMO ISP publication hub (exact sheet/cell PENDING — confirm at RFQ)
8Inverter replacement cost0.08AUD / Wp (one-off, yr 12)Model assumption (bounded); Huawei SUN2000-330KTL-H1 indicative replacement per watt — list price confirmed at RFQ via Huawei SUN2000-330KTL-H1 product page
9Discount rate (real)5.0% / yrARENA investment-discount guidance, commercial-scale PV (referenced in AEMO 2024 ISP Inputs & Assumptions workbook). Document: 2024 ISP Inputs and Assumptions, AEMO — AEMO ISP publication hub (exact sheet/cell PENDING — confirm at RFQ)
10Avoided grid tariff (blended)0.28AUD / kWhModel assumption (bounded); consistent with the small-commercial ToU band reported in AER retail tariff data (AER annual Retail Energy Market Performance report, latest revision at RFQ)

3.1 Bounded model defaults (explicit, not sourced)

The following defaults were not stated in the draft inputs and are presented as explicit bounded model assumptions; they are the values used by the scenario model:

4. scenario TCO results

The two tables below are the computed output of the Tradvolt TCO model for this scenario. These are the only financial figures on this page. Prose elsewhere refers back to these tables and does not assert any other number.

TCO summary
MetricValue
CurrencyAUD
Horizon (years)25
Discount rate5.00 %
Total undiscounted cost (AUD)400,699.99
Total discounted cost / PV of costs (AUD)342,844.44
Total undiscounted benefit (AUD)3,159,277.28
Total discounted benefit (AUD)1,729,122.68
NPV (AUD)1,386,278.24
IRR0.3961
Simple payback (year)2.57
Discounted payback (year)2.82
LCOE (AUD/kWh)0.0648

LCOE convention used here is the discounted-cost-only levelised cost: LCOE = PV of costs ÷ PV of lifetime generation, with PV of costs = 342,844.44 AUD and lifetime generation derived from the year-by-year kWh column in §5. The avoided-grid benefit is reported separately as NPV and is not netted into the LCOE numerator. This is the "levelised cost" figure, not a "total cost of ownership" figure; the two are reported distinctly and are not interchangeable.

5. Year-by-year cash flow

Year-by-year cash flow
YearCost (AUD)Benefit (AUD)Net (AUD)Discount factorDiscounted net (AUD)Energy (kWh)
0275,000.000.0000-275,000.001.00-275,000.000.0000
13,300.00109,200.00105,900.000.9524100,857.14390,000.00
23,366.00110,503.41107,137.410.907097,176.79388,440.00
33,433.32111,822.38108,389.060.863893,630.55386,886.24
43,501.99113,157.09109,655.110.822790,213.53385,338.70
53,572.03114,507.73110,935.710.783586,921.03383,797.34
63,643.47115,874.50112,231.030.746283,748.52382,262.15
73,716.34117,257.58113,541.240.710780,691.64380,733.10
83,790.66118,657.16114,866.500.676877,746.17379,210.17
93,866.48120,073.46116,206.980.644674,908.06377,693.33
103,943.81121,506.65117,562.850.613972,173.39376,182.56
114,022.68122,956.96118,934.270.584769,538.41374,677.83
1224,103.14124,424.57100,321.430.556855,862.73373,179.11
134,185.20125,909.70121,724.500.530364,553.10371,686.40
144,268.90127,412.56123,143.660.505162,195.92370,199.65
154,354.28128,933.36124,579.080.481059,924.67368,718.85
164,441.37130,472.30126,030.940.458157,736.23367,243.98
174,530.19132,029.62127,499.430.436355,627.58365,775.00
184,620.80133,605.53128,984.730.415553,595.82364,311.90
194,713.21135,200.24130,487.030.395751,638.15362,854.65
204,807.48136,813.99132,006.520.376949,751.87361,403.24
214,903.63138,447.01133,543.380.358947,934.38359,957.62
225,001.70140,099.51135,097.810.341846,183.17358,517.79
235,101.73141,771.74136,670.000.325644,495.83357,083.72
245,203.77143,463.92138,260.160.310142,870.04355,655.39
255,307.84145,176.31139,868.470.295341,303.55354,232.77

6. Model assumptions & limitations

7. Certification block

Hardware-and-installation expectations for a project of this size. Each row cites the issuing body and the standard designation with edition; always confirm against the latest revision at the issuing body.

IEC 61215-1:2021 / IEC 61215-2:2021

Crystalline-silicon module design qualification and performance. Required basis for STC claims. Catalogue at IEC Webstore; cite designations IEC 61215-1:2021 and IEC 61215-2:2021 verbatim.

UL 61730-1 (PV module safety)

Photovoltaic (PV) module safety qualification — Part 1. See UL 61730-1 standard page.

IEC 62109-1 / IEC 62109-2

Power-converter (inverter) safety. Required for grid-connected inverter registration with DNSPs. Catalogue at IEC Webstore; cite designations IEC 62109-1:2010 and IEC 62109-2:2011 verbatim.

AS/NZS 5033:2021

Australian installation and safety standard for PV arrays. Drives array wiring, isolator, and mounting rules. Obtain the current revision from Standards Australia at RFQ.

AS/NZS 4777.2:2020

Grid connection of inverter systems. Defines voltage and frequency ride-through; required for all DNSPs. Obtain the current revision from Standards Australia at RFQ.

CEC Approved Product Listing

Clean Energy Council listing is the precondition for STC creation under the Renewable Energy Target. Verify both the inverter and module appear on the current listing at the time of procurement.

ISO 14001 (installer)

Environmental management system. Common requirement for commercial-scale procurement tenders.

8. HS code block & duty lookup

Indicative Harmonised System codes for the principal components. Duty rates are listed as PENDING: do not treat the duty percentages below as fact, and verify against the current Australian Border Force working tariff before any customs declaration.

ComponentHS code (AUS)Description (excerpt)Duty rate
Crystalline PV modules8541.43.00Photovoltaic cells, assembled in modules or made up into panelsPENDING — verify at abf.gov.au
String inverters8504.40.00Static converters; power-supply units for PVPENDING — verify at abf.gov.au
Mounting structure (aluminium/steel)7610.90.00 or 7308.90.00Aluminium / iron-steel structuresPENDING — verify at abf.gov.au
DC cabling (PV-rated)8544.60.00Other electric conductors, >1,000 VPENDING — verify at abf.gov.au

Lookup instructions. Open the Australian Border Force Working Tariff at abf.gov.au → Working Tariff. Search each 6-digit code above, then read the chapter notes, additional duties, GST, and any anti-dumping measures. Confirm preference-eligibility under the FTA in force at the time of import (e.g., ChAFTA, KAFTA, AANZFTA). Some PV modules may be subject to anti-dumping/countervailing measures that vary by exporter; cross-check the current measures list at trade.gov and cbp.gov for analogous US practice where relevant.

Disclaimer. Duty rates and HS classifications shown as PENDING have not been asserted as fact. Final classification and duty assessment rest with the importer of record and Australian Border Force at the time of entry. Tradvolt does not provide customs advice.

9. Next steps

Request Quote via Tradvolt RFQ Download scenario model (CSV)

The primary CTA above routes to the Tradvolt RFQ form. The secondary CTA downloads the scenario model CSV that produced the figures in §4 and §5 (same inputs as the page; same outputs, cell-for-cell). Procurement teams should reference the equipment anchor in §2 (Huawei SUN2000-330KTL-H1 + Jinko Tiger Neo 580 W) and the horizon (25 yr, 5.00 % real) when submitting. Equipment revisions, OEM manual titles, and exact revisions are recorded per shipment in the RFQ flow.

Sources index

  1. CSIRO, GenCost 2023-24: Project technology cost estimates, 2024, p. 22, Table 4 — CSIRO GenCost 2023-24
  2. IEC 61215-1:2021 — Crystalline silicon PV modules — Design qualification and type approval, Part 1 — catalogue at IEC Webstore
  3. IEC 61215-2:2021 — Crystalline silicon PV modules — Design qualification and type approval, Part 2 — catalogue at IEC Webstore
  4. IEC 62109-1:2010 — Safety of power converters for use in photovoltaic power systems, Part 1 — catalogue at IEC Webstore
  5. IEC 62109-2:2011 — Safety of power converters for use in photovoltaic power systems, Part 2 — catalogue at IEC Webstore
  6. UL 61730-1 — Photovoltaic (PV) Module Safety Qualification — Part 1 — UL 61730-1 standard page
  7. AEMO, 2024 Integrated System Plan — Inputs and Assumptions workbook, accessed via AEMO ISP publication hub (exact sheet/cell PENDING — confirm at RFQ)
  8. Huawei FusionSolar, SUN2000-330KTL-H1 product page — Huawei SUN2000-330KTL-H1
  9. JinkoSolar, Tiger Neo N-series product page — JinkoSolar product page (exact model and datasheet revision confirmed at RFQ; Jinko datasheet PDFs are gated by region)
  10. K2 Systems, N-Rack ground-mount system product page — K2 Systems N-Rack ground-mount system (manual revision confirmed at RFQ; downloads are bot-walled)
  11. Australian Border Force — Working Tariff lookup — abf.gov.au
  12. TradVolt RFQ form (live) — /rfq/