Factory Solar 5 MWp ZA — Use Case & TCO
Verdict (5 MWp DC factory rooftop PV, Gauteng/Highveld, Eskom grid-tied, 25-year horizon, evidence date 2026-09-22): NPV = ZAR 91,153,381.94; simple payback 3.03 years; discounted payback 3.77 years at a 10.00% WACC; LCOE = 0.7032 ZAR/kWh (excl. VAT); IRR = 33.85%. Equipment commit: LONGi Hi-MO 5m LR5-72HBD-550M bifacial mono-PERC module paired with Huawei SUN2000-330KTL-H1 (330 kW, 1500 V DC, 8-MPPT) string inverter. Limitation: figures are bound to the scenario model's stated inputs (specific yield 1,650 kWh/kWp/yr after 6% rooftop derating, 0.5%/yr linear module degradation, 85% self-consumption ratio, 0.0%/yr real tariff escalation); see Inputs table for the full bound.
Decision Table (base case, 10.00% WACC, 25-year horizon)
| Metric | Value |
|---|---|
| NPV | ZAR 91,153,381.94 |
| IRR | 33.85% |
| Simple payback | 3.03 years |
| Discounted payback | 3.77 years |
| LCOE (excl. VAT) | 0.7032 ZAR/kWh |
| Total discounted cost (PV of costs) | ZAR 50,754,836.10 |
| Total discounted benefit | ZAR 141,908,218.04 |
| Total undiscounted cost | ZAR 76,002,146.64 |
| Total undiscounted benefit | ZAR 418,502,814.19 |
| Discount rate / currency | 10.00% nominal / ZAR |
1. Inputs Table (model assumption unless cited)
| Input | Value | Basis |
|---|---|---|
| System size | 5,000 kWp (DC) | Model assumption: 5 MWp factory-rooftop class. |
| Commit module | LONGi Hi-MO 5m LR5-72HBD-550M (550 Wp bifacial mono-PERC, 144 half-cell) | Public product page: https://www.longi.com/en/products/modules/hi-mo-5m/; module family datasheet LONGi Hi-MO 5m. |
| Commit inverter | Huawei SUN2000-330KTL-H1 (330 kW, 1500 V DC, 8-MPPT, 3-phase, IP66) | Public product page: https://solar.huawei.com/en/products/sun2000-330ktl-h1. |
| Specific yield (year 1) | 1,650 kWh/kWp/yr | EU PVGIS-SARAH2 Highveld baseline for Gauteng industrial-roof band, reduced 6% for rooftop tilt/azimuth derating (https://re.jrc.ec.europa.eu/pvg_tools/en/). |
| Degradation | 0.5%/yr linear (modules) | Model assumption, within IEA PVPS Trends in PV Applications 2024 tier-1 median band (https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/). |
| Discount rate (WACC) | 10.00% nominal | Model assumption for SA corporate green-tech capex. |
| Horizon | 25 years | Model assumption, aligned with module service life. |
| Tariff scenarios (excl. VAT) | ZAR 1.40 / 1.85 / 2.40 per kWh | Eskom Megaflex low / weighted ToU / peak-heavy ToU reference bands per Eskom Distribution Tariffs & Charges hub (https://www.eskom.co.za/distribution/tariffs-and-charges/) and NERSA pricing reference (https://www.nersa.org.za/electricity/pricing-and-tariffs/). Confirm current schedule at RFQ. |
| Self-consumption ratio | 85% of generation | Model assumption for SA factory daytime load vs. solar curve. |
| Export tariff (residual 15%) | ZAR 0.78/kWh (excl. VAT) | Model assumption, aligned to Eskom Megaflex off-peak reference band (https://www.eskom.co.za/distribution/tariffs-and-charges/). |
| Inverter replacement reserve | ZAR 900,000 at year 12 | Model assumption: Huawei SUN2000-330KTL-H1 string-inverter replacement at end of OEM warranty envelope. |
| Asset residual value (model default) | Not credited at horizon end | Model assumption: residual_value.amount = 0 ZAR; residual_value.year = 25. |
| PV-tariff escalation (model default) | 0.0%/yr above CPI (i.e. real tariff held constant) | Model assumption: asset.pv.tariff_escalation_pct = 0; SARB 3–6% CPI target band cited (https://www.resbank.co.za/en/home/what-we-do/monetary-policy). |
2. CAPEX Build-up (model basis; sums reconcile to the computed Year-0 cost line)
| Line | Rate (ZAR/Wp) | kWp | Subtotal (ZAR) |
|---|---|---|---|
| Modules (LONGi Hi-MO 5m LR5-72HBD-550M) | 1.55 | 5,000 | 7,750,000 |
| Inverter (Huawei SUN2000-330KTL-H1, AC-side) | 0.95 | 5,000 (Wp DC scaled) | 4,750,000 |
| Racking + BoS | 1.85 | 5,000 | 9,250,000 |
| EPC + margin | 2.40 | 5,000 | 12,000,000 |
| Hardware + EPC subtotal | 6.75 | 5,000 | 33,750,000 |
| Grid-interconnection + metering | — | — | 2,250,000 |
| Project-development (sunk, amortised) | — | — | 1,500,000 |
| Total CAPEX (excl. VAT) | — | — | 37,500,000 |
| Contingency 8% | — | — | 3,000,000 |
| Total installed CAPEX (excl. VAT) — Year-0 cost line | — | — | 40,500,000 |
| VAT 15% (recoverable in many cases — shown separately) | — | — | 6,075,000 |
3. TCO Summary (scenario model output, copy verbatim)
| Metric | Value |
|---|---|
| Currency | ZAR |
| Horizon (years) | 25 |
| Discount rate | 10.00 % |
| Total undiscounted cost (ZAR) | 76,002,146.64 |
| Total discounted cost / PV of costs (ZAR) | 50,754,836.10 |
| Total undiscounted benefit (ZAR) | 418,502,814.19 |
| Total discounted benefit (ZAR) | 141,908,218.04 |
| NPV (ZAR) | 91,153,381.94 |
| IRR | 0.3385 |
| Simple payback (year) | 3.03 |
| Discounted payback (year) | 3.77 |
| LCOE (ZAR/kWh) | 0.7032 |
4. Year-by-year Cash Flow (scenario model output, copy verbatim)
| Year | Cost (ZAR) | Benefit (ZAR) | Net (ZAR) | Discount factor | Discounted net (ZAR) | Energy (kWh) |
|---|---|---|---|---|---|---|
| 0 | 40,500,000.00 | 0.0000 | -40,500,000.00 | 1.00 | -40,500,000.00 | 0.0000 |
| 1 | 725,000.00 | 13,938,375.00 | 13,213,375.00 | 0.9091 | 12,012,159.09 | 8,250,000.00 |
| 2 | 761,250.00 | 14,146,056.79 | 13,384,806.79 | 0.8264 | 11,061,823.79 | 8,208,750.00 |
| 3 | 799,312.50 | 14,356,833.03 | 13,557,520.53 | 0.7513 | 10,185,965.84 | 8,167,706.25 |
| 4 | 839,278.13 | 14,570,749.85 | 13,731,471.72 | 0.6830 | 9,378,779.95 | 8,126,867.72 |
| 5 | 881,242.03 | 14,787,854.02 | 13,906,611.99 | 0.6209 | 8,634,911.91 | 8,086,233.38 |
| 6 | 925,304.13 | 15,008,193.04 | 14,082,888.91 | 0.5645 | 7,949,423.65 | 8,045,802.21 |
| 7 | 971,569.34 | 15,231,815.12 | 14,260,245.78 | 0.5132 | 7,317,760.89 | 8,005,573.20 |
| 8 | 1,020,147.81 | 15,458,769.17 | 14,438,621.36 | 0.4665 | 6,735,723.42 | 7,965,545.34 |
| 9 | 1,071,155.20 | 15,689,104.83 | 14,617,949.63 | 0.4241 | 6,199,437.62 | 7,925,717.61 |
| 10 | 1,124,712.96 | 15,922,872.49 | 14,798,159.53 | 0.3855 | 5,705,331.10 | 7,886,089.02 |
| 11 | 1,180,948.60 | 16,160,123.29 | 14,979,174.68 | 0.3505 | 5,250,109.35 | 7,846,658.58 |
| 12 | 2,139,996.03 | 16,400,909.12 | 14,260,913.09 | 0.3186 | 4,543,966.40 | 7,807,425.28 |
| 13 | 1,301,995.84 | 16,645,282.67 | 15,343,286.83 | 0.2897 | 4,444,403.66 | 7,768,388.16 |
| 14 | 1,367,095.63 | 16,893,297.38 | 15,526,201.75 | 0.2633 | 4,088,534.18 | 7,729,546.22 |
| 15 | 1,435,450.41 | 17,145,007.51 | 15,709,557.10 | 0.2394 | 3,760,743.07 | 7,690,898.49 |
| 16 | 1,507,222.93 | 17,400,468.13 | 15,893,245.20 | 0.2176 | 3,458,833.22 | 7,652,443.99 |
| 17 | 1,582,584.08 | 17,659,735.10 | 16,077,151.02 | 0.1978 | 3,180,778.62 | 7,614,181.77 |
| 18 | 1,661,713.28 | 17,922,865.15 | 16,261,151.87 | 0.1799 | 2,924,711.10 | 7,576,110.86 |
| 19 | 1,744,798.94 | 18,189,915.84 | 16,445,116.90 | 0.1635 | 2,688,908.02 | 7,538,230.31 |
| 20 | 1,832,038.89 | 18,460,945.59 | 16,628,906.70 | 0.1486 | 2,471,781.02 | 7,500,539.16 |
| 21 | 1,923,640.84 | 18,736,013.68 | 16,812,372.84 | 0.1351 | 2,271,865.54 | 7,463,036.46 |
| 22 | 2,019,822.88 | 19,015,180.28 | 16,995,357.41 | 0.1228 | 2,087,811.23 | 7,425,721.28 |
| 23 | 2,120,814.02 | 19,298,506.47 | 17,177,692.45 | 0.1117 | 1,918,373.05 | 7,388,592.67 |
| 24 | 2,226,854.72 | 19,586,054.22 | 17,359,199.49 | 0.1015 | 1,762,403.11 | 7,351,649.71 |
| 25 | 2,338,197.46 | 19,877,886.42 | 17,539,688.96 | 0.0923 | 1,618,843.10 | 7,314,891.46 |
5. Cert / Standards Block (commit equipment)
| Item | Standard | Citation |
|---|---|---|
| Modules — LONGi Hi-MO 5m LR5-72HBD-550M | IEC 61215-1:2021 ed2 (design qualification); IEC 61215-1-1:2021 ed2 (c-Si specific); IEC 61730-1:2016 ed2 (PV module safety — construction) | IEC Webstore IEC 61215-1:2021 ed2; IEC 61215-1-1:2021 ed2; IEC 61730-1:2016 ed2; UL 61730-1 product page UL 61730-1. |
| Inverter — Huawei SUN2000-330KTL-H1 (330 kW, 1500 V DC, 8-MPPT, IP66) | IEC 62109-1:2010 (PCE safety, general); IEC 62109-2:2011 (PCE safety, inverters); NRS 097-2-1 (SA grid code) | IEC Webstore IEC 62109-1:2010; IEC 62109-2:2011; Huawei product page SUN2000-330KTL-H1. |
| Installation | SANS 10142-1; SANS 10186 | To be verified by EPC. |
| Safety | Occupational Health and Safety Act (OHS Act), Construction Regulations 2014 | To be verified by EPC. |
6. HS Code & Duty (lookup PENDING)
| Component | HS code (likely) | Duty rate (SA) | Status |
|---|---|---|---|
| PV modules (silicon) | 8541.43 | PENDING | Lookup via SARS Customs & Excise Tariff (https://www.sars.gov.za/customs-and-excise/tariff/); SARS homepage https://www.sars.gov.za/. |
| Inverters (static converters) | 8504.40 | PENDING | Lookup via SARS Customs & Excise Tariff (https://www.sars.gov.za/customs-and-excise/tariff/); SARS homepage https://www.sars.gov.za/. |
| Mounting structures (aluminium / steel) | 7610.90 / 7326.90 | PENDING | Lookup via SARS Customs & Excise Tariff (https://www.sars.gov.za/customs-and-excise/tariff/); classify by base metal. |
Disclaimer: HS classifications and duty rates above are lookup placeholders only and are not asserted as fact. Confirm via the official SARS Tariff Search before procurement.
7. Call-to-Action
Request a written RFQ for a 5 MWp factory rooftop solar PV system in South Africa
8. Sources
| Claim | Citation (URL) |
|---|---|
| EU PVGIS-SARAH2 Highveld year-1 specific yield baseline | https://re.jrc.ec.europa.eu/pvg_tools/en/ |
| IEA PVPS tier-1 module degradation band | https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/ |
| Eskom Distribution Tariffs & Charges hub (Megaflex reference) | https://www.eskom.co.za/distribution/tariffs-and-charges/ |
| NERSA electricity pricing & tariffs (Eskom schedule decisions) | https://www.nersa.org.za/electricity/pricing-and-tariffs/ |
| Stats SA CPI mid-cycle / SARB inflation target band (3–6%) | https://www.resbank.co.za/en/home/what-we-do/monetary-policy |
| LONGi Hi-MO 5m module family (commit LR5-72HBD-550M) | https://www.longi.com/en/products/modules/hi-mo-5m/ |
| Huawei SUN2000-330KTL-H1 string inverter (330 kW, 1500 V DC, 8-MPPT, 3-phase) | https://solar.huawei.com/en/products/sun2000-330ktl-h1 |
| IEC 61215-1:2021 ed2 — PV module design qualification (Part 1: test requirements) | https://webstore.iec.ch/en/publication/61345 |
| IEC 61215-1-1:2021 ed2 — c-Si specific requirements | https://webstore.iec.ch/en/publication/61346 |
| IEC 61730-1:2016 ed2 — PV module safety (Part 1: construction) | https://webstore.iec.ch/en/publication/25674 |
| IEC 62109-1:2010 — PCE safety general requirements | https://webstore.iec.ch/en/publication/6470 |
| IEC 62109-2:2011 — PCE safety, inverters | https://webstore.iec.ch/en/publication/6471 |
| UL 61730-1 PV module safety qualification (product page) | https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1 |
| SARS customs tariff lookup (homepage) | https://www.sars.gov.za/ |
| SARS Customs & Excise Tariff (ZA tariff docs) | https://www.sars.gov.za/customs-and-excise/tariff/ |
| RFQ submission (site path only) | /rfq/ |