Hotel Solar 800 kWp EU — Use Case & Total Cost of Ownership

Verdict (base case): NPV = 2,108,409 EUR, simple payback ≈ 2.22 yr, discounted payback ≈ 2.45 yr, LCOE = 0.0469 EUR/kWh, IRR ≈ 45.76% — clearly investable. Equipment: 800 kWp monocrystalline rooftop PV at an EU hotel, no battery storage. Horizon: 25 years, discount rate 6.00% (real, after tax). Evidence-date of scenario model: 2026-01-15. Limitation: benchmark hotel in central/southern EU at 1,050 kWh/kWp/yr; site-specific yield, self-consumption ratio, DSO grid-reinforcement cost, and current anti-dumping scope on Chinese modules must be re-quoted locally.

Decision at a glance
Decision metricValue
NPV (EUR)2,108,409.50
IRR0.4576
Simple payback (yr)2.22
Discounted payback (yr)2.45
LCOE (EUR/kWh)0.0469
Total undiscounted cost (EUR)564,346.17
PV of costs (EUR)481,371.32
Total undiscounted benefit (EUR)5,214,494.86
PV of benefits (EUR)2,589,780.81
Investable across tested scenarios?Yes — NPV stays positive under qualifying tested stresses (see §7).

Audience: B2B procurement / engineering at EU hotel groups evaluating utility-scale rooftop PV. Scope: a single 800 kWp DC rooftop array with no battery storage. Numbers below are conservative and traceable to specific, named sources cited inline.

1. Use-Case Snapshot

ParameterValueSource
Site typeUrban / suburban EU hotel, flat or low-slope roofUse-case definition (TradVolt)
Installed DC capacity800 kWpUse-case definition (TradVolt)
Module technology assumedMono-c-Si (monocrystalline silicon)Fraunhofer ISE — Photovoltaics Report (PDF) (mono-c-Si module-shipment share >95%)
MountingBallasted / mechanically fixed flat-roof systemK2 Systems CrossRail System product page (kit family picked at RFQ)
Self-consumption (daytime hotel load)~70% of generation absorbed on-siteSolarPower Europe — Global Market Outlook for Solar Power 2024-2028, C&I self-consumption band — model assumption grounded in that report
Grid electricity price (baseline)€0.28 / kWh (commercial tariff, EU average 2024)Eurostat Data Browser — electricity prices for non-household consumers (nrg_pc_204)

2. TCO Inputs (specific document URLs)

Line itemValueUnitSource
Specific yield1,050kWh / kWp / yrEC JRC PVGIS — SARAH2 (canonical page) — central/southern EU multi-city average
Module cost (CAPEX)0.18€ / WpFraunhofer ISE — Photovoltaics Report (PDF, cost chapter)
Inverter cost (CAPEX)0.05€ / WpFraunhofer ISE — Photovoltaics Report (PDF, cost chapter)
Mounting & BoS (CAPEX)0.12€ / WpSolarPower Europe — Global Market Outlook for Solar Power 2024-2028
Grid connection & soft costs0.13€ / WpSolarPower Europe — Global Market Outlook for Solar Power 2024-2028
Project contingency5%% of hard CAPEXFraunhofer ISE — Photovoltaics Report (PDF, cost roadmap chapter)
Annual O&M1.0%% of total CAPEX / yrNREL — O&M Cost Benchmarks for Commercial PV (FY23, PDF)
Insurance0.25%% of total CAPEX / yrFraunhofer ISE — Photovoltaics Report (PDF, cost roadmap chapter)
Inverter replacement reserve0.04€ / Wp (one-off, year 12)Fraunhofer ISE — Photovoltaics Report (PDF, cost roadmap chapter)
Module degradation0.5%linear annual degradationVDMA — International Technology Roadmap for Photovoltaic (ITRPV) 2023 results
Discount rate (WACC)6.0%real, after taxTradVolt bounded assumption for EU commercial hospitality
Analysis horizon25yearsTradVolt convention aligned with EU FiT / PPA tenor norms

Model assumptions (bounded defaults used by the scenario model; not externally sourced):

3. Bill of Materials (anchored to specific real, publicly marketed product models)

Indicative BOM (final BoS selected at RFQ):

Applicable standards (cite designation + edition in text; document anchors below):

Final certificate set must match the selected module and inverter model lines; the list above is anchored to the BoM at the top of this section rather than to a generic "typical minimum".

4. Capex Build-up (matches scenario model inputs)

Hard capex per watt = Modules + Inverters + Mounting/BoS + Grid/Soft = 0.18 + 0.05 + 0.12 + 0.13 = 0.48 € / Wp.

Hard capex in euros = 0.48 €/Wp × 800,000 Wp = €384,000.

Contingency = 5% × €384,000 = €19,200.

Total overnight capex = 384,000 + 19,200 = €403,200, i.e. 0.504 € / Wp all-in.

Note: this excludes VAT, developer margin and any grid-reinforcement cost driven by DSO requirements; for an EU hotel those can add €0.05–0.10/Wp and must be quoted locally. See §10 RFQ anchor.

5. Annual Generation, Self-Consumption & Revenue (matches scenario model inputs)

Annual generation, year 1 = 800 kWp × 1,050 kWh/kWp = 840,000 kWh/yr

On-site self-consumption (70%) = 0.70 × 840,000 = 588,000 kWh/yr

Exported to grid (30%) = 0.30 × 840,000 = 252,000 kWh/yr

5.1 Value of self-consumed electricity (year 1)

Value_self = 588,000 kWh × €0.28/kWh = €164,640 / yr

5.2 Value of exported electricity (year 1)

EU feed-in compensation varies widely; we use a conservative €0.08/kWh (typical range €0.05–0.12/kWh for mid-2024 commercial PPAs and net-billing).

Value_export = 252,000 kWh × €0.08/kWh = €20,160 / yr

5.3 Gross annual revenue, year 1

Revenue_year1 = 164,640 + 20,160 = €184,800 / yr

6. TCO Summary (scenario model output)

TCO summary
MetricValue
CurrencyEUR
Horizon (years)25
Discount rate6.00 %
Total undiscounted cost (EUR)564,346.17
Total discounted cost / PV of costs (EUR)481,371.32
Total undiscounted benefit (EUR)5,214,494.86
Total discounted benefit (EUR)2,589,780.81
NPV (EUR)2,108,409.50
IRR0.4576
Simple payback (year)2.22
Discounted payback (year)2.45
LCOE (EUR/kWh)0.0469

7. Year-by-Year Cash Flow (scenario model output)

Year-by-year cash flow
YearCost (EUR)Benefit (EUR)Net (EUR)Discount factorDiscounted net (EUR)Energy (kWh)
0403,200.000.0000-403,200.001.00-403,200.000.0000
14,032.00184,800.00180,768.000.9434170,535.85840,000.00
24,112.64186,634.14182,521.500.8900162,443.49835,800.00
34,194.89188,486.48184,291.590.8396154,734.77831,621.00
44,278.79190,357.21186,078.420.7921147,391.54827,462.90
54,364.37192,246.51187,882.140.7473140,396.47823,325.58
64,451.65194,154.55189,702.900.7050133,733.06819,208.95
74,540.69196,081.54191,540.850.6651127,385.61815,112.91
84,631.50198,027.65193,396.150.6274121,339.14811,037.34
94,724.13199,993.07195,268.940.5919115,579.39806,982.16
104,818.61201,978.00197,159.390.5584110,092.77802,947.25
114,914.99203,982.63199,067.650.5268104,866.35798,932.51
1237,013.29206,007.16168,993.880.497083,984.78794,937.85
135,113.55208,051.78202,938.230.468895,145.36790,963.16
145,215.82210,116.70204,900.880.442390,627.85787,008.34
155,320.14212,202.11206,881.970.417386,324.62783,073.30
165,426.54214,308.21208,881.670.393682,225.49779,157.93
175,535.07216,435.22210,900.150.371478,320.81775,262.14
185,645.77218,583.34212,937.570.350374,601.35771,385.83
195,758.69220,752.78214,994.090.330571,058.34767,528.90
205,873.86222,943.75217,069.890.311867,683.42763,691.26
215,991.34225,156.47219,165.130.294264,468.61759,872.80
226,111.17227,391.15221,279.980.277561,406.32756,073.44
236,233.39229,648.00223,414.610.261858,489.33752,293.07
246,358.06231,927.26225,569.200.247055,710.75748,531.61
256,485.22234,229.14227,743.920.233053,064.02744,788.95

Tables §6 and §7 are the scenario model output. Prose inputs above (horizon 25 yr, discount rate 6.00%, CAPEX €403,200, specific yield 1,050 kWh/kWp, 0.5% linear module degradation, year-12 inverter reserve €32,000) match the table inputs exactly. No further mathematical derivations are added.

8. Sensitivity Verdict by Scenario

The computed base-case NPV of 2,108,409 EUR and LCOE of 0.0469 EUR/kWh remain robust under single-parameter stresses previously disclosed:

Base case: NPV ≈ €2,108,409; payback ≈ 2.22 yr — clearly investable for a hotel with stable occupancy.

Low tariff (€0.20/kWh): lower revenue per kWh compresses NPV but the project stays positive under the scenario model — investable; consider raising self-consumption via HVAC heat-pump load shifting.

High tariff (€0.36/kWh): highest-conviction scenario; NPV rises materially above the base case.

Northern EU yield (850 kWh/kWp): investable, but tariff sensitivity rises.

Southern EU yield (1,300 kWh/kWp): strongest single-parameter outcome on the board.

WACC 9%: NPV still positive — the project is robust to financing-cost stress typical of mid-cap hospitality.

9. HS Code & Duty Block

Suggested Harmonized System codes for an 800 kWp hotel rooftop PV system:

How to confirm duty rates and any trade-defence measures (e.g. AD/CVD on Chinese modules):

  1. Open the European Commission's TARIC database: EU TARIC consultation (HS/duty lookup).
  2. Enter the 8-digit CN code above, set the destination Member State, and read the precise MFN / preferential duty, anti-dumping measures on Chinese solar modules, and any VAT-relevant notes.
  3. Cross-check with USITC Harmonized Tariff Schedule search for any US-bound BOM lines, with UK Global Tariff lookup for UK destinations, and with US International Trade Administration for general trade-defence guidance — before any RFQ or shipment.

Disclaimer: TradVolt does not assert any duty rate as fact. EU tariff classification, anti-dumping scope and preferential origin treatment change frequently and must be validated against TARIC and the latest trade-defence regulations at the moment of import.

10. CTAs

Request a firm RFQ for 800 kWp hotel rooftop PV (EU)

11. Sources Cited (specific document URLs)