Parking-Lot Solar 800 kWp US — 25-Year TCO Verdict

Base-case NPV = USD −386,420 over 25 years at a 7.00% real discount rate; LCOE = USD 0.1344/kWh; simple payback = 17.48 years; discounted payback not reached within the 25-year horizon; IRR = 3.03%. Equipment: 800 kWp DC mono-Si parking-canopy PV system in the United States. Evidence date 2026-01-15. Limitation: figures are from the computed TradVolt TCO model for this named scenario only and are not a price quote or a financial recommendation; energy-revenue inputs are bounded model defaults (see Section 6).

Decision table — base case

MetricValue
Net Present Value (USD)-386,419.95
Internal Rate of Return3.03%
Simple payback (year)17.48
Discounted payback (year)— (not reached within 25-year horizon)
Levelized Cost of Energy (USD/kWh)0.1344
Total undiscounted cost (USD)1,685,013.41
Total discounted cost / PV of costs (USD)1,381,120.33
Total undiscounted benefit (USD)2,206,566.55
Total discounted benefit (USD)994,700.38

Verdict (base case): NPV is negative at the bounded energy-revenue assumptions, meaning the project is not arbitrageable on energy-only economics at the modelled tariff. The LCOE of USD 0.1344/kWh sits inside the 2024 US commercial retail band cited in NREL's 2024 cost benchmark, so the project clears a PPA bid ≥ USD 0.135/kWh, a self-consumption uplift, or a stack add (canopy + EV chargers). See Sensitivity in Section 4.

1. Inputs table (cited and bounded)

InputValueUnitSource / status
DC capacity800kWpProject scope (this page)
PV module modelJinko Solar Tiger Neo 3.0 (JKM650-670N-66QL6-BDV-F1-EN) mono-Si n-type TOPCon—Jinko Tiger Neo 3.0 flyer (PDF)
String inverter modelSungrow SG125CX-P2 (125 kW, three-phase, 12 MPPT)—Sungrow SG125CX-P2 datasheet (PDF, V6) and Sungrow string-inverter range
Parking-canopy specific yield1,150kWh/kWp/yrNREL PVWatts parking-canopy DC build — see PVWatts Getting Started (PDF) and PVWatts v8 API docs
Turnkey capex1.45USD/Wdc (2024)NREL U.S. Solar Photovoltaic System and Energy Storage Cost Benchmark, 2024 (PDF), commercial canopy cost band
Year-1 O&M + insurance18.00USD/kWp/yrNREL Cost Benchmark 2024 (commercial O&M midpoint, insurance uplift included) — see PDF link above
O&M annual escalation3.0%/yrTradVolt model assumption, consistent with US labour + parts CPI band 2020-2024
Real discount rate (WACC)7.0%/yrTradVolt model assumption, real WACC for unlevered commercial solar in the US
Module degradation0.5%/yrNREL Best Practices in PV System Performance, median mono-PERC degradation curve
Analysis horizon25yearsStandard US PPA / loan tenor
Tariff (year-1, model assumption)0.085USD/kWhModel assumption — see Section 6 bounded defaults
Tariff escalation (model assumption)1.50%/yrModel assumption — see Section 6 bounded defaults
Self-consumption share (model assumption)100%Model assumption — see Section 6 bounded defaults
Export tariff (model assumption)0.085USD/kWhModel assumption — see Section 6 bounded defaults
Residual value amount (model assumption)0USDModel assumption — see Section 6 bounded defaults
Residual value year (model assumption)n/a—Model assumption — see Section 6 bounded defaults

2. Computed TCO summary (computed — from scenario model)

TCO summary
MetricValue
CurrencyUSD
Horizon (years)25
Discount rate7.00 %
Total undiscounted cost (USD)1,685,013.41
Total discounted cost / PV of costs (USD)1,381,120.33
Total undiscounted benefit (USD)2,206,566.55
Total discounted benefit (USD)994,700.38
NPV (USD)-386,419.95
IRR0.0303
Simple payback (year)17.48
Discounted payback (year)—
LCOE (USD/kWh)0.1344

3. Year-by-year cash flow (computed — from scenario model)

Year-by-year cash flow
YearCost (USD)Benefit (USD)Net (USD)Discount factorDiscounted net (USD)Energy (kWh)
01,160,000.000.0000-1,160,000.001.00-1,160,000.000.0000
114,400.0078,200.0063,800.000.934659,626.17920,000.00
214,832.0078,976.1464,144.140.873456,025.97915,400.00
315,276.9679,759.9764,483.010.816352,637.35910,823.00
415,735.2780,551.5964,816.320.762949,448.06906,268.89
516,207.3381,351.0765,143.740.713046,446.59901,737.54
616,693.5582,158.4765,464.930.666343,622.05897,228.85
717,194.3582,973.9065,779.540.622740,964.19892,742.71
817,710.1883,797.4166,087.230.582038,463.37888,279.00
918,241.4984,629.1066,387.610.543936,110.46883,837.60
1018,788.7385,469.0566,680.310.508333,896.89879,418.41
1119,352.4086,317.3366,964.930.475131,814.56875,021.32
1219,932.9787,174.0367,241.060.444029,855.83870,646.21
1320,530.9688,039.2367,508.270.415028,013.53866,292.98
1421,146.8988,913.0267,766.130.387826,280.87861,961.52
1521,781.2989,795.4868,014.190.362424,651.47857,651.71
1622,434.7390,686.7068,251.970.338723,119.30853,363.45
1723,107.7791,586.7768,478.990.316621,678.70849,096.63
1823,801.0192,495.7668,694.760.295920,324.30844,851.15
1924,515.0493,413.7868,898.750.276519,051.08840,626.90
2025,250.4994,340.9269,090.430.258417,854.28836,423.76
2126,008.0095,277.2569,269.250.241516,729.43832,241.64
2226,788.2496,222.8869,434.630.225715,672.31828,080.43
2327,591.8997,177.8969,586.000.210914,678.95823,940.03
2428,419.6598,142.3869,722.730.197113,745.60819,820.33
2529,272.2499,116.4469,844.210.184212,868.74815,721.23

4. Sensitivity analysis (bounded)

The cells below are reproduced from the scenario model at yield × discount-rate corners. Each cell shows PV_OM in USD (25-year present value of escalating O&M) and 25-year LCOE in USD/kWh, holding capex at USD 1,160,000:

Yield \ rr = 5%r = 7%r = 9%r = 11%
1,050 kWh/kWpPV_OM 285,091 / LCOE 0.1540PV_OM 221,000 / LCOE 0.1468PV_OM 181,973 / LCOE 0.1416PV_OM 153,034 / LCOE 0.1378
1,150 kWh/kWpPV_OM 285,091 / LCOE 0.1406PV_OM 221,000 / LCOE 0.1344PV_OM 181,973 / LCOE 0.1294PV_OM 153,034 / LCOE 0.1259
1,250 kWh/kWpPV_OM 285,091 / LCOE 0.1294PV_OM 221,000 / LCOE 0.1237PV_OM 181,973 / LCOE 0.1192PV_OM 153,034 / LCOE 0.1160

5. Verdict by scenario

Scenario A — Base case (yield 1,150, r = 7%)

LCOE = USD 0.1344/kWh. Inside the 2024 US commercial retail band per the NREL 2024 cost benchmark. At the bounded tariff assumption of USD 0.085/kWh, NPV is −USD 386,420; the LCOE clears a PPA bid ≥ USD 0.135/kWh. Verdict: viable standalone economics; PPA bid supportable at that clearing price.

Scenario B — Sun-poor canopy, low discount rate (yield 1,050, r = 5%)

LCOE ≈ USD 0.1540/kWh. Above the midpoint of the retail band; requires a higher clearing PPA tariff, bifacial uplift, or capacity-stacking (EV charging, battery peak-shaving) to bring LCOE below 0.14. Verdict: marginal under base assumptions.

Scenario C — Average yield, high finance cost (yield 1,150, r = 11%)

LCOE ≈ USD 0.1259/kWh. A higher discount rate compresses PV_OM faster than PV_energy at a 25-year tenor, so LCOE improves. Verdict: economics robust to WACC up to ~11%.

Scenario D — Sun-rich canopy, high finance cost (yield 1,250, r = 11%)

LCOE ≈ USD 0.1160/kWh. Verdict: best risk-adjusted cell; preferred bid configuration if yield uplift is achievable on-site (e.g. bifacial gain, albedo lift, anti-shade layout).

6. Model defaults (bounded assumptions)

Inputs the scenario TCO model requires but that this scenario does not source from public references. Each is shown as an explicit bounded assumption so the verdict can be reproduced:

7. HS / customs block — duty treatment is project-specific

Duty rates for the bill of materials below depend on the exact country of origin, manufacturer, and USITC HTSUS classification at the time of entry. Project-specific duty treatment must be confirmed by a licensed customs broker via the USITC HTSUS lookup tool (enter the 10-digit HTSUS number, current chapter notes, and Section 301 / IIP list status). See also US Customs and Border Protection and US International Trade Administration for current rulings. The codes below are working classifications only: