Use-Case / TCO — Airport GSE Solar 300 kWp (AU)

Verdict: NPV = AUD 1,233,185 (positive) over a 25-year horizon at a 7.00% discount rate; simple payback 3.28 yr, discounted payback 3.84 yr; LCOE AUD 0.0886/kWh. Equipment: 518 × LONGi Hi-MO 7 LR7-72HGD bifacial modules on Schletter Fix Z-Prof mounting, 2 × Sungrow SG125HT three-phase string inverters (250 kW AC total). Location: Australian regional airport (Ausgrid distribution area, NSW). Horizon: 25 years. Discount rate: 7.00% nominal. Evidence date: 2024-11-15. Limitation: site-specific specific-yield (1,580 kWh/kWp/yr) is a bounded model assumption; replace with a Solcast / PVsyst site simulation before financial close.

Decision summary (computed)
MetricValue
CurrencyAUD (nominal)
Horizon (years)25
Discount rate7.00 %
Total undiscounted cost (AUD)591,170.44
Total discounted cost / PV of costs (AUD)469,477.90
Total undiscounted benefit (AUD)3,972,941.68
Total discounted benefit (AUD)1,702,662.73
NPV (AUD)1,233,184.83
IRR0.3193
Simple payback (year)3.28
Discounted payback (year)3.84
LCOE (AUD/kWh)0.0886

1. Inputs Table

InputValueUnitSource
System size (DC nameplate)300.44 (518 × 580 W)kWpLONGi Hi-MO 7 module family
Module family / modelLONGi Hi-MO 7 (HPBC 2.0 back-contact; LR7-72HGD)—LONGi Hi-MO 7 product page (610 W, up to 24.8% efficiency)
Inverter family / modelSungrow SG125HT (×2, 250 kW AC total)—Sungrow string inverter range (incl. SG125HT C&I 3-phase)
Mounting systemSchletter Fix Z-Prof (AS/NZS 5033:2021 compliant clamp; install manual Rev. 04-2023)—Schletter Group fixed-tilt systems category — exact manual revision confirmed at RFQ
Module datasheet warranty (linear)12-yr product / 30-yr linear power; bifaciality up to 80%—LONGi Hi-MO 7 datasheet
Performance ratio (PR)0.85—CEC Products Program (PR band 0.80–0.90 typical for AU commercial rooftop) — bounded assumption
Specific yield, AU airport site1,580kWh/kWp/yrBounded model assumption — replace with site Solcast TMY before financial close
CapEx (turnkey rooftop)1,250AUD/kWpCEC commercial rooftop cost guidance 2024 — bounded assumption within ±10%
Fixed OpEx (O&M + insurance)1.5% of CapEx/yrBounded model assumption
Inverter replacement (year 12)120AUD/kWpSungrow SG-HT service manual (capacitor-replace interval) + bounded assumption
Blended commercial tariff (Ausgrid EA029)0.28AUD/kWhAusgrid business & commercial tariffs (EA029 BLNT2AU, incl. GST)
Tariff escalation3.0%/yrBounded assumption — RBA target-band midpoint
Module degradation0.5%/yrBounded assumption consistent with LONGi linear-power warranty
Discount rate (WACC, nominal)7.0%/yrBounded assumption within AER nominal WACC band
Analysis horizon25yearsBounded assumption consistent with PV module linear-warranty term
Self-consumption share (model default)85% of generationBounded model assumption (GSE chargers operate daytime — to be confirmed by site load profile)
Export tariff (model default)0.05AUD/kWhBounded model assumption — small-export FiT band NSW 2024
Residual value (model default)0.00AUDBounded model assumption (conservative, set to zero at year 25)
Residual value year (model default)25yearBounded model assumption (end-of-horizon)

2. TCO Summary (verbatim from scenario model)

TCO summary
MetricValue
CurrencyAUD
Horizon (years)25
Discount rate7.00 %
Total undiscounted cost (AUD)591,170.44
Total discounted cost / PV of costs (AUD)469,477.90
Total undiscounted benefit (AUD)3,972,941.68
Total discounted benefit (AUD)1,702,662.73
NPV (AUD)1,233,184.83
IRR0.3193
Simple payback (year)3.28
Discounted payback (year)3.84
LCOE (AUD/kWh)0.0886

3. Computed Cash-Flow Table (verbatim from scenario model)

Year-by-year cash flow
YearCost (AUD)Benefit (AUD)Net (AUD)Discount factorDiscounted net (AUD)Energy (kWh)
0375,000.000.0000-375,000.001.00-375,000.000.0000
15,625.00116,537.67110,912.670.9346103,656.70474,695.20
25,737.50119,433.63113,696.130.873499,306.61472,321.72
35,852.25122,401.56116,549.310.816395,138.95469,960.12
45,969.30125,443.24119,473.940.762991,146.10467,610.31
56,088.68128,560.50122,471.820.713087,320.72465,272.26
66,210.45131,755.23125,544.780.666383,655.78462,945.90
76,334.66135,029.35128,694.680.622780,144.58460,631.17
86,461.36138,384.83131,923.470.582076,780.66458,328.02
96,590.58141,823.69135,233.110.543973,557.85456,036.38
106,722.40145,348.01138,625.610.508370,470.23453,756.19
116,856.84148,959.91142,103.060.475167,512.14451,487.41
1242,993.98152,661.56109,667.580.444048,693.72449,229.98
137,133.86156,455.20149,321.340.415061,963.05446,983.83
147,276.54160,343.11153,066.570.387859,361.86444,748.91
157,422.07164,327.64156,905.570.362456,869.80442,525.16
167,570.51168,411.18160,840.670.338754,482.30440,312.54
177,721.92172,596.20164,874.280.316652,194.97438,110.97
187,876.36176,885.21169,008.860.295950,003.62435,920.42
198,033.89181,280.81173,246.930.276547,904.22433,740.82
208,194.56185,785.64177,591.080.258445,892.91431,572.11
218,358.45190,402.41182,043.960.241543,966.00429,414.25
228,525.62195,133.91186,608.290.225742,119.95427,267.18
238,696.14199,982.99191,286.850.210940,351.37425,130.85
248,870.06204,952.57196,082.510.197138,657.00423,005.19
259,047.46210,045.64200,998.180.184237,033.75420,890.17

4. Scenario Verdict

5. Cert & Compliance Block

6. HS Code & Tariff Block (lookup instructions)

ComponentHS subheadingTariff lookup toolDuty rate (AU MFN)
Crystalline-Si PV modules8541.43ABF current tariff lookup0% (free, MFN) — confirm subheading & any FTA preference
String inverters (> 1 kW)8504.40ABF current tariff lookup0% (free, MFN)
PV-rated DC cable8544.60ABF current tariff lookup0% (free, MFN)
Aluminium mounting structure7610.90ABF current tariff lookup5% (verify FTA preference)
Steel mounting structure7308.20ABF current tariff lookup5% (verify FTA preference)
DC combiners / isolators8536.90ABF current tariff lookup0% (free, MFN)

Lookup instructions: confirm the exact subheading and any FTA preferential rate (e.g. KAFTA, AANZFTA, CPTPP, RCEP, ChAFTA) on the ABF tariff-lookup tool before quoting a landed cost. PV modules under HS 8541.43 are free of MFN duty in Australia; aluminium mounting under 7610.90 attracts 5% MFN unless an FTA preference applies. For non-AU destinations use the corresponding national lookup tool: USITC HTS (US), UK Global Tariff, EU TARIC, Japan Customs, NZ Customs Working Tariff, SARS (ZA), GRA (GH), URA (UG).

Disclaimer: TradVolt does not provide legal or customs advice. HS classifications and duty rates are the importer's responsibility and must be confirmed with a licensed customs broker or the Australian Border Force. Numbers in this article are engineering estimates for an indicative TCO and are not a financial recommendation.

7. Calls to Action

Request a formal RFQ via the TradVolt RFQ form. Use-case tag can be added as a query string: https://tradvolt.com/rfq/?use_case=airport-gse-solar-300kwp-au.